| name | sterilization-validation-planner |
| description | Sterilization process validation planning skill for EO, radiation, and steam sterilization |
| allowed-tools | ["Read","Write","Glob","Grep","Edit","Bash"] |
| metadata | {"specialization":"biomedical-engineering","domain":"science","category":"Sterilization and Manufacturing","skill-id":"BME-SK-026"} |
| graph | {"domains":["domain:biomedical-engineering"],"skillAreas":["skill-area:statistical-analysis","skill-area:data-analysis","skill-area:compliance-automation"],"workflows":["workflow:experiment-design","workflow:peer-review-cycle"],"roles":["role:biomedical-engineer","role:lab-technician"]} |
Sterilization Validation Planner Skill
Purpose
The Sterilization Validation Planner Skill supports sterilization process development and validation for medical devices, ensuring sterility assurance levels per ISO standards and FDA guidance.
Capabilities
- Sterilization method selection guidance
- Bioburden determination protocol
- Dose setting (ISO 11137) or half-cycle development
- IQ/OQ/PQ protocol templates
- Sterility test requirements
- Parametric release guidance
- Revalidation scheduling
- Material compatibility assessment
- Biological indicator selection
- Process challenge device design
- Dose audit planning
Usage Guidelines
When to Use
- Selecting sterilization methods
- Planning validation activities
- Developing validation protocols
- Establishing revalidation programs
Prerequisites
- Product materials characterized
- Packaging system defined
- Bioburden data available
- Sterilization facility identified
Best Practices
- Select method based on material compatibility
- Validate worst-case configurations
- Plan for ongoing process monitoring
- Document all parameters thoroughly
Process Integration
This skill integrates with the following processes:
- Sterilization Validation
- Sterile Barrier System Validation
- Design for Manufacturing and Assembly (DFMA)
- Design Control Process Implementation
Dependencies
- ISO 11135 (EO)
- ISO 11137 (radiation)
- ISO 17665 (steam)
- AAMI standards
- Sterilization service providers
Configuration
sterilization-validation-planner:
methods:
- ethylene-oxide
- gamma-radiation
- e-beam
- steam
- dry-heat
validation-phases:
- IQ
- OQ
- PQ
sal-targets:
- 10-3
- 10-6
Output Artifacts
- Method selection rationale
- Bioburden protocols
- Dose setting reports
- IQ/OQ/PQ protocols
- Validation reports
- Parametric release procedures
- Revalidation schedules
- Monitoring plans
Quality Criteria
- Method appropriate for product
- SAL target achieved
- Validation protocols comprehensive
- Material compatibility verified
- Parametric release justified
- Revalidation program established