| name | PE-9_power-equipment-and-cabling |
| description | Protect power equipment and power cabling for the system from damage and destruction. |
| category | configuration |
| version | 5.2.0 |
| author | cyberstrike-official |
| tags | ["nist","sp800-53","rev5","pe-9","pe"] |
| tech_stack | ["any"] |
| cwe_ids | [] |
| chains_with | ["PE-4"] |
| prerequisites | [] |
| severity_boost | {"PE-4":"Chain with PE-4 for comprehensive security coverage"} |
PE-9 Power Equipment and Cabling
High-Level Description
Family: Physical and Environmental Protection (PE)
Framework: NIST SP 800-53 Rev 5
Organizations determine the types of protection necessary for the power equipment and cabling employed at different locations that are both internal and external to organizational facilities and environments of operation. Types of power equipment and cabling include internal cabling and uninterruptable power sources in offices or data centers, generators and power cabling outside of buildings, and power sources for self-contained components such as satellites, vehicles, and other deployable systems.
What to Check
How to Test
Step 1: Review Documentation
Examine the System Security Plan (SSP) and related artifacts for PE-9 implementation details. Verify the organization has documented how this control is satisfied.
Step 2: Validate Implementation
# For cloud environments, use cloud-audit-mcp tools
# For on-premises, review system configurations directly
# Example: Check if account management policies exist
grep -r "account.management\|access.control" /etc/security/ 2>/dev/null
Step 3: Test Operating Effectiveness
Verify the control is actively functioning, not just documented. Check logs, configurations, and operational evidence.
Tools
| Tool | Purpose | Usage |
|---|
| Manual Review | Documentation and interview-based | N/A |
Remediation Guide
Control Statement
Protect power equipment and power cabling for the system from damage and destruction.
Implementation Guidance
Organizations determine the types of protection necessary for the power equipment and cabling employed at different locations that are both internal and external to organizational facilities and environments of operation. Types of power equipment and cabling include internal cabling and uninterruptable power sources in offices or data centers, generators and power cabling outside of buildings, and power sources for self-contained components such as satellites, vehicles, and other deployable systems.
Risk Assessment