| name | plenum-diagnostics-and-tooling |
| description | How to MEASURE Plenum's runtime behavior instead of eyeballing it — the SQLite app.db schema with copy-pasteable diagnostic queries, the Logs page (Live Feed / Cycle History) and event-logger categories, what every Metrics chart actually computes (duty cycle, degree-minutes, overshoot histogram, time-to-target), the live-state endpoints and /ws stream, and ready-to-run scripts (cycle_report, overshoot_stats, event_tail, hvac_quality, ws_watch) for cycle reports and HVAC-quality analysis (short-cycling, oscillation, chronic overshoot, drifting rooms). Load when you need numbers, history, or evidence about what the system did. |
Plenum diagnostics and tooling
This skill is about measurement: turning "the bedroom feels wrong" into a
query, a chart interpretation, or a script run that yields a number. Plenum
persists a rich diagnostic trail in SQLite — nearly every question about past
behavior is answerable without touching the running process.
When NOT to use this skill:
- You have a symptom and need ranked causes →
plenum-debugging-playbook (it owns triage; this skill owns the instruments it tells you to point at things).
- You need the °F-storage / write-boundary contract →
plenum-architecture-contract.
- You need what a config knob does or its default →
plenum-config-and-flags.
- You need domain theory (what overshoot/short-cycling physically are) →
hvac-zoning-reference.
- You need to run the app or find where it's deployed →
plenum-run-and-operate.
Jargon used below (one-line definitions; theory in hvac-zoning-reference):
cycle = one engine-driven HVAC run from setpoint-command to termination;
deadband = tolerance band around target within which a room counts as "at target";
overshoot = how far past target a room's temperature went;
short cycle = HVAC run too brief for the compressor's health;
holdover = presence-triggered activity window that outlives the last motion event;
duty cycle = fraction of wall-clock time HVAC was running;
degree-minutes = ∫|setpoint − thermostat temp| dt, an "unmet demand" integral.
1. The SQLite DB as diagnostic surface
Where it is and how to open it
- Path:
${DATA_DIR}/app.db. DATA_DIR defaults to /data in the backend
(smart_vent/backend/main.py:42-43) and is exported as /config by the
add-on's run.sh (as of 2026-07, v0.22.1). Local dev: wherever you pointed
DATA_DIR.
- WAL mode is on (
PRAGMA journal_mode=WAL in the schema). Reading a live DB
is safe; if you copy it elsewhere, copy app.db-wal and app.db-shm too or
you lose the most recent writes.
- Never write to a production DB. Open read-only:
sqlite3 "file:/config/app.db?mode=ro"
If the sqlite3 CLI is unavailable (it is not in every container), Python's
stdlib works everywhere:
python3 -c "import sqlite3,sys; c=sqlite3.connect('file:/config/app.db?mode=ro',uri=True); [print(r) for r in c.execute(sys.argv[1])]" "SELECT key,value FROM system_settings"
All scripts in this skill's scripts/ dir open mode=ro and take the DB
path as their first argument.
Conventions that will bite you if unknown
| Convention | Detail |
|---|
| Temperatures | Always stored °F (absolute and delta alike). See plenum-architecture-contract for the write-boundary contract. |
| Timestamps | Naive UTC ISO strings (2026-07-04T11:48:00.123456) — db._dts() strips tzinfo on write. Bucket to local time with SQLite's date(col,'localtime') like the metrics code does. Exception: schedules.expires_at is naive local wall-clock (#359). |
| Durations | Not stored; derive with (julianday(ended_at)-julianday(started_at))*86400.0 seconds — the same expression db.py uses. |
| Running cycle | cycle_logs.ended_at IS NULL. |
| JSON columns | cycle_logs.rooms_json ({room_id: {name, source}}; source ∈ schedule/presence/override/safety — safety rooms are pulled in by the #367 envelope backstop, cycle_engine.py:3013), vents_at_start/_end, event_log.details, room_cycle_states.trigger_detail. |
Schema map (tables you'll actually query — full DDL in smart_vent/backend/db.py SCHEMA + _MIGRATIONS, lines 38–425)
| Table | Grain | Key columns |
|---|
cycle_logs | one HVAC cycle | id, thermostat_entity_id, started_at, ended_at (NULL=running), mode (heating/cooling), ended_reason, rooms_json, setpoint_at_start/_end, thermostat_temp_at_start/_end, outside_temp_at_start/_end, vents_at_start/_end, in_min_runtime_hold |
room_cycle_states | one room's participation in one cycle | PK (cycle_id, room_id), target_temp, reached_at, vent_closed_at, temp_at_start/_end, joined_at (NULL = joined at cycle start), role (active | overflow #254), trigger_detail |
cycle_temp_samples | one temp reading per engine tick (60 s) per active room | cycle_id, room_id, timestamp, room_temp, thermostat_temp, setpoint |
cycle_setpoint_history | one setpoint command | cycle_id, timestamp, setpoint, reason |
cycle_vent_events | one cycle-boundary vent action | cycle_id, timestamp, entity_id, room_id, action, reason |
event_log | one Live-Feed row (ring buffer, max 5000 rows, trimmed every 100 inserts) | id, timestamp, level, category, message, details (JSON) |
room_overrides | one active manual override per room | PK room_id, target_temp, expires_at |
presence_holdover_state | one active holdover per room | PK room_id, last_detected_at, expires_at |
daily_thermostat_metrics / monthly_thermostat_metrics | per-thermostat rollups (#85) | date/month, heating_seconds, cooling_seconds, cycle_count, completed/timeout/aborted_count, avg_cycle_duration_seconds |
system_settings | key/value flags | see plenum-config-and-flags Layer 3 for the key catalog |
rooms, room_sensors, room_vents, room_presence_sensors, schedules, thermostat_configs | configuration | see plenum-config-and-flags |
Copy-pasteable queries (all verified against a DB built from the real DDL)
Recent cycles with durations:
SELECT id, mode, started_at, ended_at, ended_reason,
ROUND((julianday(ended_at)-julianday(started_at))*1440.0,1) AS dur_min
FROM cycle_logs ORDER BY started_at DESC LIMIT 20;
Currently-running cycle(s):
SELECT id, thermostat_entity_id, mode, started_at FROM cycle_logs WHERE ended_at IS NULL;
Per-room reached/closed timing for one cycle (NULL reached_at = never hit target):
SELECT rcs.room_id, rcs.target_temp, rcs.temp_at_start, rcs.temp_at_end, rcs.role,
rcs.reached_at, rcs.vent_closed_at, rcs.joined_at
FROM room_cycle_states rcs WHERE rcs.cycle_id = '<CYCLE_ID>';
Setpoint history for a cycle (every engine setpoint command with reason):
SELECT timestamp, setpoint, reason FROM cycle_setpoint_history
WHERE cycle_id = '<CYCLE_ID>' ORDER BY timestamp;
Temperature trajectory for a cycle (one row per 60 s tick per active room):
SELECT timestamp, room_id, room_temp, thermostat_temp, setpoint
FROM cycle_temp_samples WHERE cycle_id='<CYCLE_ID>' ORDER BY timestamp;
Vent events for a cycle:
SELECT timestamp, entity_id, room_id, action, reason
FROM cycle_vent_events WHERE cycle_id='<CYCLE_ID>' ORDER BY timestamp;
Warnings/errors from the engine (event_log by category):
SELECT timestamp, level, message FROM event_log
WHERE category = 'engine' AND level IN ('warning','error')
ORDER BY id DESC LIMIT 20;
Active overrides and presence holdovers (timestamps are UTC, so compare against UTC now):
SELECT o.room_id, r.name, o.target_temp, o.expires_at
FROM room_overrides o LEFT JOIN rooms r ON r.id = o.room_id
WHERE o.expires_at > strftime('%Y-%m-%dT%H:%M:%S','now');
SELECT h.room_id, r.name, h.last_detected_at, h.expires_at
FROM presence_holdover_state h LEFT JOIN rooms r ON r.id = h.room_id;
System-settings dump:
SELECT key, value FROM system_settings ORDER BY key;
Daily rollups (empty until the 00:05-local APScheduler job or a manual
POST /api/metrics/rollup/daily has run):
SELECT * FROM daily_thermostat_metrics ORDER BY date DESC LIMIT 7;
ended_reason taxonomy (verified in cycle_engine.py, as of v0.22.1)
completed — cycle reached its goal (_terminate_cycle default).
timeout — hard cycle_timeout_hours hit (_terminate_cycle(reason="timeout")).
aborted: <reason> — _abort_cycle prefixes aborted: ; reasons seen in
code: thermostat unavailable, system disabled, vacation mode,
no active rooms, no compatible rooms after filtering.
- Metrics bucket these with
_ROLLUP_REASON_BUCKETS (db.py:1407):
completed = exact completed; timeout = timeout OR aborted: timeout%;
aborted = other aborted:%.
cycle_vent_events.action values (verified emit sites in cycle_engine.py)
opened_at_start, closed_reached_target, force_reopened_max_closed,
reopened_min_runtime_hold, closed_overflow_hold, opened_overflow_hold
(the last three are the #237/#254 overflow-conditioning actions).
Note: closed_at_end appears in models.py's comment and the
/api/metrics/.../vent-timeline disclosure note, but no emit site exists in
the engine as of v0.22.1 — don't expect those rows in fresh data.
2. The Logs page and the event logger
The Logs page (frontend/src/pages/Logs.tsx) has three tabs: Live
Feed, Cycle History, Retention.
Live Feed = event_log + /ws
EventLogger.log(level, category, message, details)
(backend/event_logger.py) writes an event_log row and broadcasts it as
a log_event WS frame — so the Live Feed and the DB table are the same data.
Rows never raise; a failed DB write still broadcasts.
Categories actually emitted (verified by grepping every .log( call site, v0.22.1):
| Category | Emitted from | Typical content |
|---|
engine | cycle_engine, vent_controller, scheduler | cycle start/end/abort, setpoint moves, safety-guard trips, stale sensors |
system | scheduler, routes | enable/disable, unit changes, log clears |
api | routes | user mutations (rooms/schedules/config edited) |
ha | main | HA connect/reconnect |
presence | scheduler | presence activations / holdover expiries |
dev | ha_client | Dev-Mode simulated HA calls |
reconcile | cycle_engine | periodic reconciliation pass results |
The UI filter list matches: Logs.tsx:858 CATEGORIES = ["all","system","api","engine","presence","ha","dev","reconcile"]. Levels: info/warning/error.
REST equivalent (same filters the UI uses):
curl 'http://<host>:8099/api/logs/events?category=engine&level=warning,error&limit=50'
Params: limit, offset, category, since, until (ISO UTC), level (comma-separated).
Retention: event_log is trimmed to 5000 rows (db.py:_EVENT_LOG_MAX)
every 100th insert, plus a purge job driven by event_log_retention_days
(default 7; Retention tab / GET,POST /api/settings/log-retention). Cycle
logs purge via cycle_log_retention_days (default 30).
Cycle History drilldown
- List:
GET /api/logs?limit=&offset=&since=&until= → cycle_logs rows plus a
had_overflow badge flag (true when any room_cycle_states.role='overflow').
- Drilldown:
GET /api/logs/{cycle_id}/detail → the cycle + per-room
states (target, reached_at, vent_closed_at, trigger_detail, role) + all
vent events + setpoint history.
- Chart data:
GET /api/logs/{cycle_id}/temp-samples[?room_id=].
Use the drilldown for: runaway cycles (long duration + timeout), rooms that
never reach target (reached_at NULL), and external-setpoint surprises
(setpoint history rows whose reason you don't recognize).
3. The Metrics page — what each chart computes
Charts live in frontend/src/components/charts/MetricsCharts.tsx; the math
lives in smart_vent/backend/db.py (compute_* functions); endpoint↔chart
mapping is in docs/metrics.md. All computations read cycle_logs live
(rollup tables only back long-horizon trends), consider completed cycles
only (ended_at IS NOT NULL), and bucket by local date of started_at.
| Metric | Computation (db.py) | Interpretation |
|---|
| Summary tiles / duty cycle % | compute_thermostat_summary: Σ cycle durations by mode ÷ range seconds ×100. Home view multiplies range by thermostat count so % stays ≤100. | Sustained duty >50% in mild weather → undersized system, fighting zones, or cycles that won't terminate. Compare against outside temp. |
| Cycles / avg duration / hours per day | compute_thermostat_timeseries (metric=cycles/avg_duration/hours) | Many short cycles = short-cycling (see §5). A sudden avg-duration jump often correlates with an outside-temp swing — check chart 4d before blaming the engine. |
| Cycles vs outside temp (scatter) | compute_cycles_vs_outside_temp: each completed cycle as (outside_temp_at_start, duration_minutes), colored by mode | The house's thermal-response curve. Points far off the trend at the same outside temp = anomalies worth drilling into. Empty until an outside-temp entity is configured (no backfill). |
| Time-to-target | _time_to_target_timeseries: per cycle, MIN over rooms of reached_at − COALESCE(joined_at, started_at), averaged per bucket; overflow rooms excluded | Measures the fastest room, not the slowest — a drifting room does NOT move this chart. Use scripts/hvac_quality.py §4 or per-room avg_time_to_target_seconds for laggards. |
| Completion rate (donut) | summary's completed/timeout/aborted_count via _ROLLUP_REASON_BUCKETS | High timeout share → rooms that can't reach target (closed dampers, weak airflow, unrealistic setpoints). High aborted share → check which aborted: reason dominates (query above). |
| Source breakdown (donut) | summary walks rooms_json, counting each distinct source (schedule/presence/override) once per cycle | Which trigger drives the HVAC — a cycle with both schedule and presence rooms counts once in each; the buckets are not disjoint and don't sum to cycle_count. |
| Per-room participation / heat-cool time | compute_room_metrics: participation = room's non-overflow cycle count ÷ total cycles; time = COALESCE(vent_closed_at, ended_at) − COALESCE(joined_at, started_at) | Participation near 0 for a room that should be active = its schedules/presence never fire (see the silent-zone family in plenum-debugging-playbook). |
| Degree-minutes | _degree_minutes_timeseries: trapezoid-free left-sum of |setpoint − thermostat_temp| over inter-sample gaps, using thermostat-level samples (room_id IS NULL) only | "How much conditioning was demanded." CAVEAT: as of v0.22.1 the engine's only insert_cycle_temp_sample call site (cycle_engine.py:1098) writes per-room rows — verify NULL-room rows exist (SELECT COUNT(*) FROM cycle_temp_samples WHERE room_id IS NULL) before trusting an empty chart. |
| Overshoot histogram | compute_overshoot_histogram (#290): per (cycle, room), worst wrong-side excursion vs target — cooling: max(target − min_seen, 0); heating: max(max_seen − target, 0). Room-level samples preferred, thermostat-level fallback per room. Last bin is open-ended. | Values are deltas — the UI converts with toDisplayDelta (no −32). Rendering them with the absolute formula was bug #291. Consistent multi-°F overshoot → raise deadband or check temp_offset (#86). |
| Hour heatmap | compute_hour_heatmap: each cycle spreads its seconds across the local hour cells it overlaps, 7×24 Mon–Sun grid | Conditioning at hours nobody scheduled → presence sensors firing (pets?) or overrides left active. |
| Vent timeline | get_vent_events_in_range | Cycle-boundary events only — mid-cycle movements aren't tracked; the UI shows that disclosure deliberately. |
CSV export semantics
GET /api/metrics/export.csv?scope=home|thermostat[&entity_id=][&start=&end=]
→ one row per completed cycle. This is the only read path that converts
temperatures: headers are unit-labeled (e.g. setpoint_at_start (°C)) and
values pass through _from_f() in the active display unit. Every other
API/DB temperature you see is raw °F. duration_seconds is computed at
export time.
Rollups
Daily job 00:05 local → daily_thermostat_metrics; monthly 00:10 on the 1st.
Manual: POST /api/metrics/rollup/daily {"days_back": 7} — idempotent,
range-replacing. Needed after a restore or a retention purge.
4. Live state — endpoints and the WS stream
| Endpoint | Returns |
|---|
GET /api/healthz | liveness ping |
GET /api/status | one entry per engine: thermostat_entity_id, cycle_state (idle/running/…), hvac_mode, hvac_action, current_temp, setpoint, cycle_id, cycle_started_at, per-room {room_id, avg_temp, vent_states, presence_active} — all temps °F |
GET /api/system/status | {enabled, dev_mode, mcp_enabled} |
POST /api/ha/states {"entity_ids":[…]} | HA state-cache snapshot; °C sensor values are normalized to °F in numeric (routes.py ~1379-1387) — numeric is always °F regardless of display unit |
GET /api/sensor-health | rooms with stale temp sensors (#211): age_seconds per sensor, reason stale or not_in_cache; threshold = sensor_stale_after_min setting, default 30 min (SENSOR_STALE_AFTER_MIN, cycle_engine.py:55). Healthy rooms omitted. |
GET /api/thermostat-health | unavailable climate entities (#267): unavailable_seconds, abort_after_min, cycle_running. Healthy thermostats omitted. |
GET /api/logs/events | event_log query (see §2) |
Quick health sweep from a shell:
H=http://<host>:8099
curl -s $H/api/status | python3 -m json.tool
curl -s $H/api/sensor-health | python3 -m json.tool
curl -s $H/api/thermostat-health | python3 -m json.tool
The /ws stream
Single push-only WebSocket at GET /ws (api/ws_handler.py, heartbeat
ping every 30 s). Event frame shape: {"type": <event_type>, "data": {…}}.
Types emitted (verified broadcast call sites, v0.22.1):
zone_status — per-engine snapshot from cycle_engine._maybe_broadcast
(thermostat id, hvac_mode/action, current_temp, setpoint, cycle_id,
cycle_state); raw °F.
log_event — every EventLogger row (§2).
system_enabled_changed / dev_mode_changed / mcp_enabled_changed.
Watch it from a shell with the pure-stdlib client in this skill:
python3 scripts/ws_watch.py ws://<host>:8099/ws
python3 scripts/ws_watch.py ws://<host>:8099/ws --type zone_status
python3 scripts/ws_watch.py ws://<host>:8099/ws --raw
It answers server pings, auto-reconnects, and needs no pip installs. ws://
only (no TLS) — point it at the exposed 8099 port or a port-forward, not an
HTTPS ingress URL.
5. HVAC-quality analysis from cycle data
The four failure signatures worth scanning for, and where they live in the data:
| Signature | Data test | Usual fix knob |
|---|
| Short cycling | completed cycles with duration < ~10 min | min_cycle_runtime_min (#208); also check deadband too tight |
| Rapid restarts | gap between ended_at and next started_at < ~10 min on the same thermostat | min_cycle_offtime_min (#208), overshoot_delta too small |
| Mode oscillation | heating→cooling (or reverse) within <60 min | rooms with conflicting targets on one thermostat; deadbands; see the opposite-cycle tiers in hvac-zoning-reference |
| Chronic overshoot / drift | per-room avg of temp_at_end vs target_temp (sign-normalized by mode); reached_at NULL rate | overshoot → deadband/temp_offset (#86); never-reaches → airflow, vent mapping, sensor placement |
scripts/hvac_quality.py runs all four at once and exits 1 if any red flag
fires (cron-able). scripts/overshoot_stats.py reproduces the Metrics-page
overshoot histogram offline plus a per-room breakdown the API doesn't expose.
6. The scripts
All in scripts/ next to this file. Pure stdlib (python3, no pip), DB opened
strictly read-only (file:…?mode=ro URI — verified a write attempt raises),
DB path is always the first positional argument. Tested against a throwaway
DB built from the real db.py DDL (SCHEMA + _MIGRATIONS) with 7 days of
synthetic cycles.
| Script | Usage | Output |
|---|
cycle_report.py | python3 cycle_report.py app.db [--days 7] [--thermostat climate.x] [--limit 50] | Table of recent cycles (id, mode, start, duration or RUN, setpoint/temps °F, ended_reason); summary block (counts by reason bucket, completion rate, avg duration, duty cycle); per-room reached/vent-closed timing for the latest completed cycle. |
overshoot_stats.py | python3 overshoot_stats.py app.db [--days 7] [--bin-size 1.0] [--max-bins 6] | Overshoot histogram (same math as compute_overshoot_histogram, ASCII bars), overshot %, avg/max °F-delta, per-room averages with a chronic (avg > 2°F) flag. |
event_tail.py | python3 event_tail.py app.db [-n 30] [--category engine] [--level warning,error] [--follow] | timestamp LEVEL [category] message details lines; --follow polls by id every 2 s (safe on a live WAL DB). |
hvac_quality.py | python3 hvac_quality.py app.db [--days 7] [--short-min 10] [--offtime-min 10] | The §5 four-signature scan with example offenders and RED FLAG lines; exit code 1 if any flag fired. |
ws_watch.py | python3 ws_watch.py ws://host:8099/ws [--type zone_status] [--raw] | One line per WS event; handles pings, reconnects. Tested against a minimal RFC 6455 server (handshake, masked pong, close). |
Example (hvac_quality.py output shape):
[1] short cycles (<10 min): 43/109 (39%)
cyc004 cooling 2026-06-27T16:46:00 9.0 min (completed)
RED FLAG: >20% short cycles — check min_cycle_runtime_min / deadband
[2] short off-times (<10 min between cycles): 51
[3] heat<->cool oscillations (mode flip within 60 min): 4
[4] per-room target performance:
Bedroom n=109 never_reached=24% avg_miss=+0.14°F
3 red flag(s).
Provenance and maintenance
All facts verified 2026-07-04 against v0.22.1 source. Re-verification commands
(repo root):
- Schema / DDL:
grep -n "CREATE TABLE" smart_vent/backend/db.py (lines 42–235 as of 2026-07) and _MIGRATIONS (line 357). If tables/columns change, rebuild the scripts' expectations.
- Event categories:
grep -rnoP '\.log\(\s*"\w+",\s*"\w+"' smart_vent/backend --include="*.py" | grep -v tests — currently engine, system, api, ha, presence, dev, reconcile; UI list at smart_vent/frontend/src/pages/Logs.tsx:858.
ended_reason values: grep -n '_abort_cycle(conn, reason=\|_terminate_cycle(conn, reason=' smart_vent/backend/engine/cycle_engine.py.
- Vent-event actions:
grep -n 'insert_cycle_vent_event' smart_vent/backend/engine/cycle_engine.py then read each call's action string. closed_at_end still has no emit site → if one appears, update §1.
- Degree-minutes NULL-sample caveat:
grep -rn insert_cycle_temp_sample smart_vent/backend --include='*.py' | grep -v tests — one call site (per-room) as of v0.22.1; recheck whether a thermostat-level (room_id=None) writer was added.
- Metrics endpoints & chart list:
grep -n '@routes.get("/api/metrics' smart_vent/backend/api/routes.py; docs/metrics.md.
- WS event types:
grep -rn "_broadcast(\|broadcast(" smart_vent/backend/scheduler.py smart_vent/backend/engine/cycle_engine.py.
- Constants: event-log cap
grep -n _EVENT_LOG_MAX smart_vent/backend/db.py (5000); staleness default grep -n "SENSOR_STALE_AFTER_MIN" smart_vent/backend/engine/cycle_engine.py (30.0); ports grep -n 8099 smart_vent/config.yaml.
- Scripts smoke test: build a throwaway DB by extracting
SCHEMA/_MIGRATIONS from db.py via ast.literal_eval, seed a few cycles, and run each script against it (this is how they were validated; they were not run against a production DB).
Known limits (as of 2026-07): scripts' --days filters compare against UTC
datetime.utcnow() while Metrics buckets by local date — expect ±1-day edge
differences vs the UI. ws_watch.py is plaintext-only. The mini WS server
used for testing lived in a scratchpad and is not shipped; re-testing