| description | Author a correct Vivado XDC timing constraint set from scratch — primary clocks, generated (derived) clocks, input/output delays, and timing exceptions (clock groups / false paths / multicycle paths) — for a design that has no constraints yet, or whose constraints are incomplete (unconstrained ports, missing generated clocks, unrelated async clocks reported as failing paths).
Invoke when the user says: "write constraints", "author xdc", "set up timing constraints", "no constraints yet", "constrain my clocks", "add input/output delays", "my clocks are asynchronous / I need clock groups", or whenever check_timing / report_timing_summary reports unconstrained clocks, ports, or combinational endpoints. This is the FIRST step before any timing-closure or signoff work — WNS/TNS numbers are meaningless until the design is correctly constrained.
Requires the SynthPilot MCP server connected to an OPEN Vivado session with the Tcl server running (test_connection must pass) and a project that elaborates and synthesizes.
|
Constraints Authoring (XDC from scratch)
A methodology playbook for writing a correct, complete, and honest XDC
constraint set. The goal of constraints is to tell the timing engine the truth
about the design's real timing requirements — not to make WNS look good. A
constraint that lies (a too-loose clock, a false_path on a real path) produces a
green report that does not survive on silicon. Correctness first, optimism never.
This skill stops at a timed, sane, signed-off constraint set plus a clear
list of any assumptions you had to make. It does NOT attempt timing closure
(that is the timing-closure skill's job). It hands off once timing is defined,
not met.
When to use
- A project has no XDC at all, or no timing constraints (only pin/IO
assignments) — the classic "no constraints yet".
check_timing / report_timing_summary reports unconstrained clocks,
ports, or combinational endpoints (e.g. "There are N input/output ports with
no input/output delay specified").
- The design has PLL/MMCM/clock-divider outputs that are missing
generated-clock definitions (derived clocks defaulting to the source
period, or showing up as unconstrained).
- Multiple asynchronous clock domains exist and inter-clock paths are being
analyzed (and failing) when they should be cut with
set_clock_groups.
- You need to add I/O timing budgets (
set_input_delay / set_output_delay)
for a board interface.
- A legitimate multicycle or false relationship exists that the tool
cannot infer and is currently over-constraining.
When NOT to use
- Timing is already fully constrained and you are trying to close it
(improve WNS/TNS). Use the timing-closure skill — do NOT "fix" timing by
adding exceptions here.
- CDC is the question ("is my clock crossing safe?"). Constraining async
clocks with
set_clock_groups silences the cross-domain timing report; it
does not make the crossing safe. Use the cdc-analysis skill to verify
synchronizers exist before/after you group clocks. (This skill will tell you
when to stop and call it.)
- Pure pin/placement assignment (LOC/IOSTANDARD only, no timing). Those are
create_io_constraint; that part is in-scope here but if there is no timing
question at all this skill is overkill.
- You don't know the board/interface timing numbers. Do not invent input/
output delays. Ask the user for the datasheet/board numbers, or state the
assumption explicitly and flag it.
Prerequisites (verify first)
Run these BEFORE writing anything. Do not skip — a wrong period or a clock on a
non-existent port wastes a full synthesis.
test_connection — confirm the MCP↔Vivado Tcl bridge is alive. If this
fails, stop: nothing below will work.
get_project_info — confirm a project is open and know the target part
(speed grade matters; constraints are part-agnostic but I/O delay budgets are
not).
list_source_files + set_top_module (if not set) — you must constrain the
top-level ports. Constraining ports that aren't on top is a silent no-op.
list_constraint_files — find what already exists. If there is an XDC, you
are editing, not creating from scratch; read_file it first and do not
duplicate clock definitions.
- Establish the design intent — from the user and/or
read_file on the top
module: every clock port and its frequency, which clocks are generated (PLL/
MMCM/divider), which clock domains are asynchronous to each other, and the
board-level I/O timing (source-synchronous vs system-synchronous). If any of
these is unknown, ask the user — do not guess clock periods.
You author constraints at elaboration/RTL level (against port and pin
names), but you VERIFY them against a real synthesized netlist where pin
paths (pll/CLKOUT0, reg[*]/C) actually exist. Authoring uses port names;
verification needs open_synthesized_design.
Methodology
Author in dependency order: clocks → generated clocks → I/O delays →
exceptions. Each later layer references names defined by an earlier one, so order
is not optional. One constraint class per step, then re-measure, so you can
attribute every change in the timing report to exactly one edit.
1. Inventory what exists and what's missing
check_timing — the single most important diagnostic. It reports unconstrained
clocks, missing input/output delays, combinational loops, and (critically)
appends the full port inventory so you can cross-reference which ports still
lack constraints. Read it carefully; it is your worklist.
get_all_clocks — what clocks (if any) Vivado has already inferred. Empty =
truly from scratch. Non-empty = some clocks exist (maybe from IP); do not
redefine them.
- If clocks already exist,
get_clock_info(<name>) per clock to see period and
source — confirm they match intent before building generated clocks on top.
If check_timing cannot run because nothing is elaborated, run
run_synthesis_async once to get a netlist, poll get_run_status, then
open_synthesized_design. You need a netlist to see real clock pins anyway.
2. Define PRIMARY clocks (the foundation)
For every physical clock input port (an oscillator/board clock entering the
FPGA), one create_clock_constraint:
create_clock_constraint(clock_port="<top clock port>", period_ns=<period>, name="<clk_name>")
- Period =
1000 / freq_MHz. Use the real board frequency from intent, not a
hopeful one. A 100 MHz oscillator is period_ns=10.0.
- Only create primary clocks on true clock inputs, never on internal PLL/MMCM
outputs — those are generated clocks (Step 3). Defining a primary clock on a
PLL output double-counts and corrupts analysis.
- Give every clock an explicit
name so later steps and reports are readable.
After defining all primary clocks, get_all_clocks to confirm each appears with
the intended period.
3. Define GENERATED clocks (PLL/MMCM/divider outputs)
Any clock derived inside the FPGA needs an explicit generated clock so the
engine knows the true frequency/phase relationship:
- PLL/MMCM outputs:
create_generated_clock(name="<clk_out>", source="<pll>/CLKIN1", target="<pll>/CLKOUT0", multiply_by=M, divide_by=D)
— M/D from the IP's actual configuration (e.g. 100→200 MHz is multiply_by=2).
- RTL clock dividers:
create_generated_clock(name="clk_div2", source="<clk_in port>", target="<div_reg>/Q", divide_by=2).
- Phase-shifted outputs: add
phase=<deg> (e.g. a 90° clock for source-sync DDR).
- Inverted/negedge-derived clocks:
invert=True.
- Use
multiply_by/divide_by for simple ratios; edges/edge_shift only for
genuinely non-integer or asymmetric waveforms.
Source/target are PIN paths, not ports — they only exist on the synthesized
netlist. Author them, then prove them in Step 7 with report_clock_networks /
get_all_clocks. If a generated clock shows up with the wrong period after
synthesis, the M/D or the target pin is wrong — fix it, don't paper over it.
Many IP cores (Clocking Wizard, MIG, transceivers) ship their OWN generated
clocks in their .xdc. Check report_clock_networks / the IP's constraints
first; do not redefine a clock the IP already constrains, or you create a
conflicting double definition.
4. Relate or separate the clocks (groups / uncertainty)
Now that all clocks exist, declare their relationships — this is where most
"failing paths" on a fresh design come from, and where the biggest honesty risk
lives.
- Asynchronous domains (clocks from independent sources / unrelated PLLs):
set_clock_groups(group1="<clkA>", group2="<clkB>", relationship="asynchronous").
This tells timing not to analyze paths between them.
HARD GATE: only do this for a crossing that is genuinely asynchronous AND
has a proper CDC synchronizer. Grouping clocks does not synchronize them — it
hides the report. See the classification table and Safety rails. If unsure
whether a synchronizer exists, stop and ask / run cdc-analysis; do not
group blindly.
- Mux-selected / never-simultaneous clocks: use
relationship="exclusive"
(or logically_exclusive/physically_exclusive) — not asynchronous.
- Synchronous, related clocks (e.g. PLL outputs that are integer multiples of
the same source): do NOT group them — they must be analyzed together. Only
add
set_clock_uncertainty(<jitter_ns>, clock="<clk>") to model PLL jitter/
board skew if you have a real number; otherwise leave the tool's default.
5. Budget the I/O timing (input/output delays)
For every top-level data port that crosses the chip boundary and isn't a clock,
add a delay so timing knows the external budget:
- Inputs:
set_input_delay(port_name="<port>", delay_ns=<board_delay>, clock_name="<launch clk>").
- Outputs:
set_output_delay(port_name="<port>", delay_ns=<board_delay>, clock_name="<capture clk>").
- Numbers come from the interface spec / board: trace delay + external device
tco/tsu (system-synchronous), or the source-synchronous skew window. Do not
fabricate these. If the user can't supply them, either (a) state an explicit
placeholder assumption and flag it loudly in the Output, or (b) ask. A
guessed-zero delay is a silent lie that passes in the lab and fails in the field.
- Pure asynchronous control inputs with no real launch edge (some resets,
push-buttons) are NOT given a meaningful I/O delay — they're handled as false
paths in Step 6.
- Pin location / IOSTANDARD (separate from timing) via
create_io_constraint(port_name, pin, io_standard) if the board pinout isn't
already in a pin XDC.
6. Add genuine exceptions — narrowly, with a stated reason
Exceptions tell the tool to relax analysis. Each one is a claim about the
design's behavior. Every exception requires a one-line justification, and if
the path could be real, ask the user before adding it. Prefer the narrowest
tool.
- Async reset distribution (reset asserted async, deasserted synchronously
through a reset synchronizer):
set_false_path(from_signal="<rst>", from_type="port").
Justification: "reset is recovered through a synchronizer; the async assert edge
has no timing requirement." If there is NO reset synchronizer, this is a bug —
do not false_path it; flag it.
- Static / quasi-static config registers read by a faster clock but written
rarely:
set_multicycle_path(N, from_signal="<src_reg>[*]/C", to_signal="<dst_reg>[*]/D")
with a justification of why N cycles are guaranteed by the protocol. Hold MCP is
auto-adjusted; verify it.
- CDC datapath that's already synchronized but you want a bounded skew instead
of fully cutting it:
set_max_delay(<period_ns>, from_node, to_node, datapath_only=True)
(and/or set_bus_skew for a multi-bit bus through a handshake/gray-code). This
is safer than set_clock_groups because it still bounds the path.
- Single mux-exclusive clock structures: prefer
set_clock_groups relationship="logically_exclusive" over a pile of false paths.
Never add an exception merely because a path is failing setup/hold. A failing
real path is a timing-closure problem, not a constraints problem.
7. VERIFY against a synthesized netlist (mandatory)
Constraints written against RTL are unproven until checked against real clock
networks and pins. Do this every time:
save_constraints(file_name="timing.xdc") then ensure it's in the project
(add_constraint_file / list_constraint_files). Or author the file directly
with create_constraint_file(file_name, content) for full control of ordering.
run_synthesis_async → poll get_run_status until done → open_synthesized_design.
check_timing — the unconstrained-objects count must drop to the intended
set (zero, except objects you deliberately left as no-timing async). Any
remaining "no clock"/"no input delay" is an unfinished constraint, not a pass.
get_all_clocks + report_clock_networks — confirm every clock (primary
and generated) appears with the correct period and source. A generated
clock at the wrong frequency = wrong M/D.
report_clock_interaction — the clock-pair matrix. Confirm: related clocks are
Timed, intentionally-async pairs are Ignored/partial because you grouped
them on purpose, and no pair you expected to be timed is silently ignored. This
is the honesty check on Step 4.
report_timing_summary — sanity only. At this stage you care that paths are
being analyzed correctly, not that WNS is positive. Do not declare success
on WNS here; that's closure/signoff.
8. Finalize
save_constraints the verified file; confirm it's the one in the project.
- Produce the Output report (below): every clock, every delay, every exception
with its justification, and every assumption you had to make.
- If real timing analysis is now needed → hand off to timing-closure. If any
async grouping was added → hand off to cdc-analysis to verify the
synchronizers. State the handoff explicitly.
Classification: symptom → likely cause → smallest correct constraint
Use this to decide which constraint, not just that a constraint is needed.
| Symptom (from check_timing / clock reports) | Likely cause | Smallest correct fix | Honesty gate |
|---|
| "Clock has no create_clock" | Primary clock undefined | create_clock_constraint with real period | Period must be the real board freq, not a wish |
| PLL/MMCM output clock missing or at source period | Generated clock undefined | create_generated_clock(multiply_by/divide_by from IP config) | M/D must match the IP's actual config |
| N input/output ports "no input/output delay" | I/O unbudgeted | set_input_delay/set_output_delay from interface spec | Numbers from datasheet/board — never fabricated |
| Inter-clock paths failing between unrelated clocks | Async domains analyzed as if related | set_clock_groups(... asynchronous) | ONLY if a real CDC synchronizer exists — else CDC bug, do not group |
| Mux-selected clocks both timed against each other | Tool can't infer mutual exclusivity | set_clock_groups(... logically_exclusive) | The mux must truly make them mutually exclusive |
| Path from slow config reg to fast logic fails setup | Real multicycle relationship | set_multicycle_path(N, ...) | N must be guaranteed by the protocol, justified |
| Async reset/async input path fails | Async assert with sync recovery | set_false_path(from_signal=rst, from_type=port) | A reset synchronizer must exist; else flag bug |
| Generated clock at wrong frequency after synth | Wrong M/D or wrong target pin | Fix create_generated_clock args | Re-verify with report_clock_networks — do not waive |
| Combinational loop reported | RTL bug, not a constraint | Do not constrain around it | Report to user — this is an RTL fix |
Iterate: author → synthesize → verify → refine (LOOP)
Constraints are correct only when proven on a netlist. Loop one constraint
class at a time:
- MEASURE —
check_timing + report_clock_interaction + report_clock_networks.
Record: unconstrained-object count, which clock pairs are Timed/Ignored,
generated-clock periods.
- CLASSIFY — use the table to pick the single smallest correct constraint for
the top remaining gap.
- APPLY ONE CLASS — add only that class of constraint this iteration
(all primary clocks, OR all generated clocks, OR I/O delays, OR one exception
family). Save.
- RE-SYNTHESIZE & RE-MEASURE —
run_synthesis_async → get_run_status →
open_synthesized_design → repeat Step 1's measurements.
- SHOW YOUR WORK — before/after for this iteration: unconstrained count
went X→Y, clock pair Z went Ignored→Timed (or the reverse, on purpose).
STOP conditions (stop looping and report)
- DONE:
check_timing shows zero unintended unconstrained objects; every
clock present at correct period/source in report_clock_networks; every clock
pair in report_clock_interaction is Timed-or-intentionally-Ignored with a
stated reason. → Finalize (Step 8). Note: this is constraints complete, not
timing met.
- NEEDS HUMAN INPUT: a clock period, an I/O delay number, or an async/CDC
relationship is unknown and cannot be derived. → Present what's known, list the
exact unknowns, stop and ask. Do not guess.
- NOT A CONSTRAINTS PROBLEM: the gap is an RTL/architecture issue (combinational
loop, missing synchronizer, a genuinely failing real path). → Present the
finding, recommend the RTL/CDC fix, hand off — do not add an exception to
hide it.
- THRASHING: two consecutive iterations don't reduce unintended-unconstrained
count or you're toggling a constraint back and forth. → Stop, surface the
trade-off (e.g. "this crossing is either a real CDC bug or needs a synchronizer
before I can group it"), hand back to the human.
Safety rails (do not violate)
- No fake-pass / no silencing. Never add
set_false_path,
set_clock_groups(asynchronous), set_multicycle_path, or
waive_lint_violation to make a real path's violation disappear. An exception
is a factual claim about the hardware; if it could be false, ask the user
first and record the assumption. WNS going green because you cut a path is not
closure — it's a hidden bug.
- Async grouping ≠ CDC safety.
set_clock_groups(asynchronous) removes the
cross-domain path from analysis; it does NOT add a synchronizer. Only group
domains that already have proper CDC structures. When you add any async group,
you MUST flag it for cdc-analysis in the Output.
- Real numbers only. Clock periods come from the actual oscillator/IP; I/O
delays come from the interface spec/board. Never fabricate a period or a delay
to make a report look good. If unknown → ask or flag a stated assumption.
- Smallest safe change, in order. Constraints/strategy before RTL. Define
clocks before exceptions. Prefer the narrowest tool: bound a CDC path with
set_max_delay(datapath_only=True) rather than wholesale set_clock_groups
when you only need a skew bound.
- Primary vs generated discipline. Never
create_clock_constraint on a PLL/
MMCM output or a derived clock — that double-defines and corrupts analysis. Those
are always create_generated_clock.
- Don't redefine IP-owned clocks. If a Clocking Wizard / MIG / transceiver IP
already constrains a clock (check
report_clock_networks / its XDC), do not add
a conflicting definition.
- Recommend RTL, don't silently rewrite it. If the correct fix is a reset
synchronizer, a CDC FIFO, or a logic change, report it and let the human
decide. This skill edits constraints, not source.
- Evidence before claims. "Constraints complete" REQUIRES fresh
post-synthesis
check_timing + report_clock_networks + report_clock_interaction
output in this session — never inferred from the RTL or from a prior run. Any
signoff-level timing claim (timing met) requires post-implementation
evidence and belongs to the timing-closure/signoff flow, not here.
- One change-class per iteration so cause→effect in the timing report is
attributable.
Output
Return a concise, evidence-backed report:
- Scope — created from scratch vs. completed an existing XDC; target part.
- Clocks defined — table of every clock: name, type (primary/generated),
source, period (ns) / frequency (MHz), M/D or phase for generated, verified
period from
report_clock_networks (proves it, doesn't just assert it).
- Clock relationships — every
set_clock_groups / uncertainty, with the
relationship and a one-line reason; the relevant rows of
report_clock_interaction showing the matrix is as intended.
- I/O delays — table of port → delay → reference clock, and the source of
each number (datasheet / board / assumed (flagged)).
- Exceptions — every false_path / multicycle / max_delay with its one-line
justification and whether the user confirmed it.
- Verification evidence — fresh
check_timing unconstrained-object count
(before → after, ideally → 0 unintended), confirmation all clocks appear
correctly, and that the clock-pair matrix matches intent. Quote the numbers.
- Assumptions & open questions — every value you had to assume or guess,
called out explicitly for the user to confirm.
- Handoff — explicit next step: timing-closure (to actually meet timing) and/
or cdc-analysis (mandatory if any async clock group was added) — naming the
skill, not silently ending.
Honesty footer to include verbatim when relevant: "Constraints are complete
and verified against the synthesized netlist. This means timing is now correctly
DEFINED — it does not mean timing is MET. Any async clock groups I added assume a
working CDC synchronizer exists; verify with cdc-analysis before signoff."