| name | use-related-risk-analyzer |
| description | Use-related risk analysis skill for identifying hazards associated with user interaction per IEC 62366-1 |
| allowed-tools | ["Read","Write","Glob","Grep","Edit","Bash"] |
| metadata | {"specialization":"biomedical-engineering","domain":"science","category":"Risk Management","skill-id":"BME-SK-009"} |
| graph | {"domains":["domain:biomedical-engineering"],"skillAreas":["skill-area:statistical-analysis","skill-area:data-analysis","skill-area:compliance-automation"],"workflows":["workflow:experiment-design","workflow:peer-review-cycle"],"roles":["role:biomedical-engineer","role:research-engineer"]} |
Use-Related Risk Analyzer Skill
Purpose
The Use-Related Risk Analyzer Skill identifies and evaluates hazards associated with user interaction with medical devices, implementing IEC 62366-1 usability engineering methodology and supporting human factors risk analysis.
Capabilities
- Use scenario identification
- Task analysis decomposition
- Use error categorization (perception, cognition, action)
- Known use problems database search
- Risk mitigation strategy development
- Training vs. design solution recommendations
- User interface risk analysis
- Critical task identification
- Use error root cause analysis
- Usability test planning support
- IFU effectiveness evaluation
Usage Guidelines
When to Use
- Conducting use-related risk analysis
- Planning usability engineering activities
- Designing user interfaces
- Evaluating training effectiveness
Prerequisites
- User profiles defined
- Use environments characterized
- Intended use documented
- Use scenarios identified
Best Practices
- Integrate with ISO 14971 risk management
- Prioritize inherently safe design
- Test with representative users
- Validate critical tasks
Process Integration
This skill integrates with the following processes:
- Human Factors Engineering and Usability
- Medical Device Risk Management (ISO 14971)
- Verification and Validation Test Planning
- Design Control Process Implementation
Dependencies
- IEC 62366-1 standard
- FDA Human Factors guidance
- AAMI HE75 guidelines
- Known problems databases
- User interface standards
Configuration
use-related-risk-analyzer:
user-profiles:
- healthcare-professional
- patient
- caregiver
- lay-user
error-categories:
- perception-error
- cognition-error
- action-error
use-environments:
- clinical
- home
- emergency
Output Artifacts
- Use-related risk analysis documents
- Task analysis worksheets
- Use error catalogs
- Critical task lists
- Mitigation recommendations
- Usability test specifications
- Training requirements
- IFU content recommendations
Quality Criteria
- All user groups and scenarios analyzed
- Use errors systematically identified
- Critical tasks properly validated
- Mitigation strategies prioritize safe design
- Training addresses residual use risks
- Analysis integrates with ISO 14971