| description | Dynamic simulation guidance for NeqSim. USE WHEN: running transient simulations, modeling startup/shutdown, tuning PID controllers, analyzing pressure/level dynamics, performing blowdown/depressurization, or setting up measurement devices and control loops. Covers runTransient, DynamicProcessHelper, controller tuning, and dynamic equipment configuration. |
| last_verified | 2026-07-10 |
Dynamic Simulation Guidance
Guide for transient/dynamic process simulation in NeqSim.
When to Use Dynamic Simulation
- Startup and shutdown sequences
- Controller tuning and loop analysis
- Pressure relief / blowdown scenarios
- Level and pressure dynamics
- Compressor surge analysis
- Pipeline transients (slug flow)
- Emergency depressurization (EDP/ESD)
- P&ID-derived valve actions where pressure, level, controller response, or inventory release changes with time
For valve-action studies that start from P&ID symbols and plant data, also load
neqsim-pid-process-operations to define the process graph, valve semantics,
historian tag mapping, and event schedule before running runTransient.
Dynamic Simulation Architecture
NeqSim dynamic simulation uses the runTransient(double dt) method on ProcessSystem.
Each timestep:
- All measurement devices read current values
- All controllers calculate new outputs
- All equipment updates for the timestep
- Flash calculations update thermodynamic state
Basic Dynamic Setup
import neqsim.process.processmodel.ProcessSystem;
import neqsim.process.equipment.stream.Stream;
import neqsim.process.equipment.separator.Separator;
import neqsim.process.equipment.valve.ThrottlingValve;
import neqsim.process.controllerdevice.ControllerDeviceInterface;
import neqsim.process.controllerdevice.ControllerDeviceBaseClass;
import neqsim.process.measurementdevice.LevelTransmitter;
import neqsim.process.measurementdevice.PressureTransmitter;
SystemInterface fluid = new SystemSrkEos(273.15 + 25.0, 50.0);
fluid.addComponent("methane", 0.80);
fluid.addComponent("ethane", 0.10);
fluid.addComponent("propane", 0.05);
fluid.addComponent("n-pentane", 0.05);
fluid.setMixingRule("classic");
Stream feed = new Stream("feed", fluid);
feed.setFlowRate(10000.0, "kg/hr");
Separator sep = new Separator("HP Sep", feed);
sep.setInternalDiameter(2.0);
sep.setSeparatorLength(6.0);
ThrottlingValve gasValve = new ThrottlingValve("gas valve", sep.getGasOutStream());
gasValve.setOutletPressure(20.0, "bara");
ThrottlingValve liqValve = new ThrottlingValve("liq valve", sep.getLiquidOutStream());
liqValve.setOutletPressure(10.0, "bara");
ProcessSystem process = new ProcessSystem();
process.add(feed);
process.add(sep);
process.add(gasValve);
process.add(liqValve);
process.run();
Adding Measurement Devices
PressureTransmitter PT100 = new PressureTransmitter("PT-100", sep);
PT100.setUnit("bara");
PT100.setMaximumValue(100.0);
PT100.setMinimumValue(0.0);
process.add(PT100);
LevelTransmitter LT100 = new LevelTransmitter("LT-100", sep);
LT100.setUnit("m");
process.add(LT100);
TemperatureTransmitter TT100 = new TemperatureTransmitter("TT-100", sep);
TT100.setUnit("C");
process.add(TT100);
VolumeFlowTransmitter FT100 = new VolumeFlowTransmitter("FT-100", feed);
FT100.setUnit("kg/hr");
process.add(FT100);
Controller Configuration
PID Controller
ControllerDeviceInterface LC100 = new ControllerDeviceBaseClass();
LC100.setControllerSetPoint(1.0);
LC100.setTransmitter(LT100);
LC100.setReverseActing(false);
LC100.setControllerParameters(0.5, 100.0, 10.0);
liqValve.addController("LC-100", LC100);
ControllerDeviceInterface PC100 = new ControllerDeviceBaseClass();
PC100.setControllerSetPoint(50.0);
PC100.setTransmitter(PT100);
PC100.setReverseActing(false);
PC100.setControllerParameters(1.0, 50.0, 0.0);
gasValve.addController("PC-100", PC100);
Controller Tuning Guidelines
| Loop Type | Typical Kp | Typical Ti (s) | Typical Td (s) |
|---|
| Level (averaging) | 0.5-2.0 | 60-300 | 0 |
| Level (tight) | 2.0-5.0 | 30-60 | 0-10 |
| Pressure (gas) | 0.5-2.0 | 20-100 | 0-5 |
| Flow | 0.3-1.0 | 5-30 | 0 |
| Temperature | 0.5-2.0 | 60-600 | 10-60 |
Controller Deadband (SP-PV)
ControllerDeviceBaseClass supports a native SP-PV deadband via
setDeadBand(double) / getDeadBand(). While the absolute control error stays
inside the band the controller output is frozen (holds the last valve
position) and the integral term does not accumulate; default 0 disables it.
The deadband is in the controller error unit (percent in the default percent
mode, else the configured engineering unit). This is the standard DCS averaging-
level deadband used to stop valve cycling.
levelController.setDeadBand(0.5);
Beware the deadband limit cycle. On an integrating (level) process a
deadband delays correction until the level reaches the band edge; the delayed
correction then overshoots and the cycle repeats, giving a square-wave valve
trace. Removing (or shrinking) the deadband is the usual fix. If the installed
pip neqsim predates setDeadBand, emulate it by toggling controller mode
each step: setMode(ControllerMode.MANUAL) while |PV%-SP%| <= deadband (holds
output) and setMode(ControllerMode.AUTO) otherwise (bumpless resume) - this is
numerically identical to the native deadband.
Dynamic level-loop recipe (get the sequence right)
A dynamic separator level loop only responds if the vessel is switched out of
steady-state mode and the liquid outlet valve is direct acting. The exact,
easy-to-get-wrong sequence is:
process.run();
sep.setCalculateSteadyState(false);
liqValve.setCalculateSteadyState(false);
sep.setInternalDiameter(2.0);
sep.setSeparatorLength(6.0);
sep.setLiquidLevel(0.30);
LevelTransmitter LT100 = new LevelTransmitter("LT-100", sep);
LT100.setUnit("m");
ControllerDeviceInterface LC100 = new ControllerDeviceBaseClass();
LC100.setTransmitter(LT100);
LC100.setControllerSetPoint(0.30 * sep.getInternalDiameter());
LC100.setReverseActing(false);
LC100.setControllerParameters(1.0, 300.0, 0.0);
liqValve.addController("LC-100", LC100);
java.util.UUID id = java.util.UUID.randomUUID();
for (int i = 0; i < 600; i++) {
process.runTransient(1.0, id);
}
Gotchas:
- Level pinned at 0.5 — the vessel is still in steady-state mode; call
setCalculateSteadyState(false) on the separator (and its outlet valve).
- Level runs away — the liquid-outlet level controller is reverse acting; it
must be
setReverseActing(false) (direct acting). A gas-outlet pressure valve
is also direct acting (false); reverse acting is for cases where more output
reduces the measured value (e.g. a controller manipulating an inlet/feed valve).
- Set
setLiquidLevel after run() — a steady-state solve resets the level,
so set the starting level and geometry after the first run().
- For an averaging level loop, use a loose
Kp and long Ti (see the tuning
table) and consider an SP-PV deadband only with care (see the limit-cycle note
above).
After the run, use ControllerPerformanceMetrics.fromEventLog(LC100.getEventLog())
(or LC100.getPerformanceMetrics()) to score the tuning (IAE/ISE/ITAE, PV
variability, valve travel and reversals, settling time) — see the KPI section below.
Loop-tuning KPIs (ControllerPerformanceMetrics)
ControllerPerformanceMetrics
(neqsim.process.controllerdevice.ControllerPerformanceMetrics) computes the
standard loop-tuning KPIs from a controller event log (or from raw time / PV / SP
/ output arrays) so tuning studies report consistent numbers without
re-implementing the definitions. It is the preferred way to compare two PID
tunings on the same disturbance.
Metrics: getIntegralAbsoluteError() (IAE), getIntegralSquaredError() (ISE),
getIntegralTimeAbsoluteError() (ITAE, time referenced to the first sample),
getProcessValueStandardDeviation() (PV variability), getPeakAbsoluteError(),
getControllerOutputTravel() (total valve travel), getControllerOutputReversals()
(valve direction reversals), and getSettlingTime() (time of the last sample
outside the settling band, default 2 % of max(|SP|, 1)).
ControllerPerformanceMetrics kpi = LC100.getPerformanceMetrics();
ControllerPerformanceMetrics kpi2 =
ControllerPerformanceMetrics.fromEventLog(LC100.getEventLog(), 0.05);
double iae = kpi.getIntegralAbsoluteError();
double valveTravel = kpi.getControllerOutputTravel();
int reversals = kpi.getControllerOutputReversals();
double settlingTime = kpi.getSettlingTime();
logger.info("IAE={} travel={} reversals={} settle={} s", iae, valveTravel, reversals, settlingTime);
ControllerPerformanceMetrics kpi3 =
ControllerPerformanceMetrics.fromArrays(time, pv, sp, op);
- Integral criteria use trapezoidal integration over the sample intervals, so
irregular time steps are handled correctly.
- A lower IAE/ISE/ITAE means tighter regulation; lower valve travel and
reversals means gentler actuator duty. Tuning trade-offs usually pit the two
against each other (tighter control costs more valve movement).
resetEventLog() on the controller before the disturbance so the KPIs cover
only the window of interest.
Anti-Surge Control (dynamic)
AntiSurgeController (neqsim.process.controllerdevice.AntiSurgeController) is a
purpose-built reverse-acting PI controller that reads the compressor
getDistanceToSurge() and drives a recycle (spill-back) ThrottlingValve open
when the margin falls below the set point, then closes it again on recovery.
import neqsim.process.controllerdevice.AntiSurgeController;
AntiSurgeController asc = new AntiSurgeController("anti-surge", compressor, recycleValve);
asc.setSurgeMarginSetPoint(0.10);
asc.setProportionalGain(400.0);
asc.setIntegralTime(20.0);
asc.setOpeningRange(0.0, 100.0);
asc.setActive(true);
recycleValve.addController("anti-surge", asc);
Control law each transient step: error = setPoint - distanceToSurge,
integral += Kp/Ti * error * dt, opening = clamp(Kp*error + integral) with
anti-windup; the controller applies the opening directly to the recycle valve.
Reproducible benchmark. AntiSurgeDynamicBenchmark
(neqsim.process.util.scenario.AntiSurgeDynamicBenchmark) drives the real
controller against a transparent first-order gas-path surrogate
m_{k+1} = m_k - d*dt + a*(u/100)*dt (m = distance to surge, d = disturbance
rate, a = recycle authority, u = valve opening %). It is deterministic and
always converges, so it is the preferred way to verify or tune the control law:
import neqsim.process.util.scenario.AntiSurgeDynamicBenchmark;
AntiSurgeDynamicBenchmark bench = new AntiSurgeDynamicBenchmark();
bench.setInitialMargin(0.30);
bench.setDisturbanceRate(0.020);
bench.setRecycleAuthority(0.060);
bench.setTimeStep(1.0);
bench.setNumberOfSteps(120);
bench.getController().setSurgeMarginSetPoint(0.10);
bench.run(false);
bench.run(true);
boolean safe = bench.isSurgeAvoided();
Critical gotchas when wiring a full dynamic recycle flowsheet:
- A fixed-factor
Splitter (setSplitFactors([0.97, 0.03])) pins the recycle
fraction in dynamic mode, so the anti-surge valve has no authority over the
actual recycle flow — the controller can hit 100% with no effect. Let the
recycle flow be set by the valve (setCv/resistance), or use the steady-state
anti-surge Calculator pattern instead.
- Once the operating point crosses left of the surge line,
getDistanceToSurge()
clamps at -1.0 and the steady solver cannot climb back out; a flowsheet
driven into deep surge will not self-heal even after the inlet is reopened.
Apply gradual/ramped disturbances and keep the machine off deep surge.
- Aggressive proportional gain can slam the recycle valve to its minimum opening,
starve a stream, and trigger an SRK flash
NaN
(PhaseSrkEos:molarVolume ... NaN). Keep gains moderate and the valve off hard
minimum.
- To demonstrate or tune the control law cleanly, prefer
AntiSurgeDynamicBenchmark (or a transparent gas-path surrogate) over a full
recycle flowsheet that can stick in deep surge.
For coordinated compressor-train studies, use
CompressorAntiSurgeApplication (neqsim.process.equipment.compressor) as the
supervisory scan layer. Each StageApplication can bind directly to real NeqSim
topology objects with bindTopology(process, compressor, hotRecycleValve, coldRecycleValve, recycleCooler, suctionMixer, hotRecycle, coldRecycle). A scan
then writes hot/cold recycle valve openings and optional compressor speed
runback to the real units, and runDynamicStep(scanInput, dt) advances the
bound ProcessSystem with runTransient().
Use this application layer when the study needs stage coordination,
startup/shutdown or trip states, hot/cold recycle split, operator diagnostics,
commissioning checks, or speed runback in one executable dynamic model. Keep
Recycle blocks algebraic unless they have explicit transient inventory
support; valve, compressor, cooler, mixer, and volume-capable equipment should
carry the dynamic response. The application layer reports
NOT_CERTIFIED_FOR_PROTECTION and is for simulation/advisory studies, not a
certified machinery-protection package.
Running Dynamic Simulation
double dt = 1.0;
int nSteps = 3600;
double[] time = new double[nSteps];
double[] pressure = new double[nSteps];
double[] level = new double[nSteps];
for (int i = 0; i < nSteps; i++) {
time[i] = i * dt;
if (i == 300) {
feed.setFlowRate(15000.0, "kg/hr");
}
process.runTransient(dt);
pressure[i] = PT100.getMeasuredValue();
level[i] = LT100.getMeasuredValue();
}
Python Dynamic Simulation
from neqsim import jneqsim
import numpy as np
import matplotlib.pyplot as plt
process.run()
dt = 1.0
n_steps = 3600
times = np.zeros(n_steps)
pressures = np.zeros(n_steps)
levels = np.zeros(n_steps)
for i in range(n_steps):
times[i] = i * dt
if i == 300:
feed.setFlowRate(15000.0, "kg/hr")
process.runTransient(dt)
pressures[i] = PT100.getMeasuredValue()
levels[i] = LT100.getMeasuredValue()
fig, (ax1, ax2) = plt.subplots(2, 1, figsize=(10, 8))
ax1.plot(times / 60, pressures)
ax1.set_ylabel("Pressure (bara)")
ax1.set_xlabel("Time (min)")
ax1.grid(True)
ax2.plot(times / 60, levels)
ax2.set_ylabel("Level (m)")
ax2.set_xlabel("Time (min)")
ax2.grid(True)
plt.tight_layout()
P&ID Valve-Action Dynamic Studies
Use this pattern when evaluating actions such as closing an outlet valve,
opening a bypass, tripping a shutdown valve, or opening a drain/vent:
- Run and validate the steady-state base case.
- Define an event schedule with action type, affected valve, start time, and ramp duration.
- Map each P&ID valve to the correct NeqSim role: control valve, boundary switch, check-valve direction constraint, or blowdown/flare path.
- Run
process.runTransient(dt) for controller and inventory dynamics, or use neqsim-depressurization-mdmt for dedicated blowdown/MDMT cases.
- Save time series for pressure, level, temperature, valve position, flow, and any flare or vent stream.
Minimum result keys: max_pressure_bara, max_level_m, min_temperature_C,
peak_flare_flow_kg_s, time_to_alarm_s, and time_to_new_steady_state_s.
Depressurization / Blowdown
ThrottlingValve bdv = new ThrottlingValve("BDV", sep.getGasOutStream());
bdv.setOutletPressure(1.0, "bara");
bdv.setCv(500.0);
Transfer Function Blocks
For more advanced control logic:
import neqsim.process.controllerdevice.TransferFunctionBlock;
TransferFunctionBlock leadLag = new TransferFunctionBlock();
Common Pitfalls
- Always run steady state first: Call
process.run() before runTransient()
- Timestep size: Start with 1.0 s, reduce if oscillating (0.1-0.5 s)
- Reverse acting: Level controllers are usually reverse-acting (level up = open valve)
- Controller windup: Large setpoint changes can cause integral windup
- Separator dimensions: Must set
setInternalDiameter() and setSeparatorLength() for meaningful level dynamics. For dynamic simulation, set directly on the separator; for design purposes, configure via SeparatorMechanicalDesign (see neqsim-api-patterns skill)
- Measurement range: Set min/max on transmitters to match process range
- Enable dynamic (inventory) mode for level loops: after
process.run() (steady), call setCalculateSteadyState(false) on the separator AND every valve, then separator.setLiquidLevel(startFraction), before runTransient. If steady-state mode is left on, the separator liquid level stays pinned at its default (0.5) and the level controller never acts. The valve Cv is auto-derived from the steady solve. A liquid-outlet level valve is setReverseActing(false) (level up -> valve opens); put a pressure controller on the gas-outlet valve so the vessel pressure is held and the level loop is isolated.
Pluggable Integrator Strategies
Beyond the default fixed-step explicit-Euler loop, ProcessSystem accepts a
pluggable IntegratorStrategy. Implementations live in neqsim.process.dynamics:
| Strategy | Class | Notes |
|---|
| Explicit Euler | ExplicitEulerIntegrator | Default; fast, conditionally stable |
| BDF-1 (Implicit Euler) | BDFIntegrator | Newton + FD Jacobian (tol 1e-8, maxIter 25). Falls back to explicit Euler if Newton diverges; check lastStepFellBack() |
import neqsim.process.dynamics.BDFIntegrator;
import neqsim.process.dynamics.ExplicitEulerIntegrator;
import neqsim.process.dynamics.IntegratorStrategy;
process.setIntegratorStrategy(new BDFIntegrator());
IntegratorStrategy current = process.getIntegratorStrategy();
For multi-area plants the strategy is propagated to every child area:
plant.setIntegratorStrategy(new BDFIntegrator()).
Event Scheduling (ESD, IOA, setpoint changes)
Time-stamped events (ESD trips, valve closures, setpoint ramps) are managed by
EventScheduler in neqsim.process.dynamics. Every call to
runTransient(dt, id) fires events with time <= currentTime at the top of
the step, before equipment runs.
import neqsim.process.dynamics.EventScheduler;
EventScheduler events = new EventScheduler();
events.scheduleEvent(120.0, "ESD trip", new Runnable() {
public void run() { esdValve.setPercentOpen(0.0); }
});
events.scheduleEvent(300.0, "Setpoint ramp", new Runnable() {
public void run() { pressureController.setControllerSetPoint(45.0); }
});
process.setEventScheduler(events);
for (int i = 0; i < nSteps; i++) {
process.runTransient(dt);
}
int fired = events.getFiredEvents().size();
int pending = events.getPendingEvents().size();
For multi-area plants install the scheduler once on the ProcessModel; it is
propagated to every child area, and plant.runTransient(dt, id) advances all
areas:
plant.setEventScheduler(events);
plant.runTransient(dt, java.util.UUID.randomUUID());
Note: EventScheduler is declared transient on ProcessSystem because
event Runnable payloads (lambdas, anonymous classes) are usually not
serializable. Re-install the scheduler after deserialising a saved process.
New Measurement Devices (v3.11)
Three new measurement devices in neqsim.process.measurementdevice complement
the existing PT/TT/LT/FT family:
| Class | Reads | Unit |
|---|
DifferentialPressureTransmitter(name, high, low) | pHigh - pLow across two streams | bar |
CompositionAnalyzer(name, stream, component, phase) | Mole fraction; phase OVERALL / GAS / LIQUID | mole/mole |
FlowRatioMeter(name, num, den, basis) | Flow ratio; basis MASS / MOLE / VOLUME | dimensionless |
import neqsim.process.measurementdevice.DifferentialPressureTransmitter;
import neqsim.process.measurementdevice.CompositionAnalyzer;
import neqsim.process.measurementdevice.FlowRatioMeter;
DifferentialPressureTransmitter dpdt = new DifferentialPressureTransmitter("dPT-1", upstream, downstream);
CompositionAnalyzer ax = new CompositionAnalyzer("AX-1", sweetGas, "methane",
CompositionAnalyzer.AnalyzerPhase.GAS);
FlowRatioMeter rxn = new FlowRatioMeter("FR-1", recycleStream, feedStream,
FlowRatioMeter.FlowBasis.MASS);