Conduct cybersecurity assessments of power grid infrastructure spanning generation, transmission substations, distribution, and EMS control centers, covering NERC CIP compliance verification, IEC 61850 (GOOSE/MMS) substation protocol analysis, and synchrophasor (PMU) network security against threats like Industroyer/CrashOverride. Use for periodic NERC CIP assessments, substation automation or EMS/SCADA security reviews, or regional entity compliance audits; not for non-BES systems or generic OT assessments without power grid specifics.
Installer avec Codex ou Claude Copiez ce prompt, collez-le dans Codex, Claude ou un autre assistant, puis laissez-le vérifier la page du skill et l'installer pour vous.
Une commande directe contourne le prompt de vérification. Examinez la source avant de l'exécuter.
Conduct cybersecurity assessments of power grid infrastructure spanning generation, transmission substations, distribution, and EMS control centers, covering NERC CIP compliance verification, IEC 61850 (GOOSE/MMS) substation protocol analysis, and synchrophasor (PMU) network security against threats like Industroyer/CrashOverride. Use for periodic NERC CIP assessments, substation automation or EMS/SCADA security reviews, or regional entity compliance audits; not for non-BES systems or generic OT assessments without power grid specifics.
When conducting periodic cybersecurity assessments of power grid facilities per NERC CIP requirements
When assessing substation automation systems using IEC 61850 GOOSE and MMS protocols
When evaluating the security of an Energy Management System (EMS) or SCADA control center
When assessing synchrophasor (PMU) networks and wide-area monitoring systems
When preparing for regional entity compliance audits or internal security reviews
Do not use for non-BES systems below NERC registration thresholds, for general OT assessment without power grid specifics (see performing-ot-network-security-assessment), or for physical security assessment of generation facilities without cyber scope.
Prerequisites
Understanding of electric power grid architecture (generation, transmission, distribution)
Familiarity with NERC CIP standards and BES Cyber System categorization
Knowledge of power grid protocols (IEC 61850, IEC 60870-5-104, DNP3, ICCP/TASE.2)
Passive monitoring tools for substation network traffic analysis
Access to EMS/SCADA architecture documentation and network diagrams
Workflow
Step 1: Map Power Grid Cyber Architecture
Identify and document all cyber systems supporting grid operations including EMS, SCADA, substation automation, and communication infrastructure.
# Power Grid Cyber Architecture Assessmentfacility_type:"Regional Transmission Organization Control Center"ems_systems:primary_ems:vendor:"GE Grid Solutions"product:"EMS/SCADA (formerly XA/21)"functions:-"State estimation"-"Automatic generation control (AGC)"-"Security-constrained economic dispatch"-"Contingency analysis"protocols:-"ICCP/TASE.2 (inter-control center)"-"DNP3 (substation RTU polling)"-"IEC 60870-5-104 (substation polling)"backup_control_center:location:"Geographically diverse backup site"sync_method:"Real-time database mirroring"switchover_time:"< 5 minutes"substation_automation:count:145system_types:-vendor:"ABB"product:"RTU560"protocol:"DNP3 over TCP/IP"count:85-vendor:"SEL"product:"SEL-3530 RTAC"protocol:"IEC 61850 MMS + GOOSE"count:40-vendor:"Siemens"product:"SICAM A8000"protocol:"IEC 60870-5-104"count:20communications:primary:"MPLS WAN (carrier-provided)"backup:"Licensed microwave radio"last_mile:"Fiber optic to substation"synchrophasor_network:pmu_count:75pdc:"GE PDC (Phasor Data Concentrator)"communication:"IEEE C37.118.2 over dedicated network"data_rate:"30-60 samples per second"
Step 2: Assess Substation Automation Security
Evaluate IEC 61850-based substation automation for protocol security, access controls, and network segmentation.