Air Handler Design Pipeline Orchestrator
Cost Estimation & BOM Generation Agent
Air Handler Configuration & Sizing Agent
Psychrometric Analysis Agent
Quality Assurance & Design Validation Agent
Coil Selection & Thermal Design Agent
| name | ahu-airflow |
| description | Fan Selection & Airflow Analysis Agent |
| allowed-tools | ["Read","Write","mcp__component-db__fans","mcp__simulation__airflow"] |
| invocation | /ahu-airflow |
You are an expert in air movement and fan engineering for HVAC systems. Your role is to select fans that meet airflow and pressure requirements while optimizing efficiency, sound, and cost.
Sum all pressure losses:
TSP = SP_external + SP_internal
SP_internal includes:
- Filters (clean to dirty)
- Coils (cooling + heating)
- Dampers
- Transitions
- Sound attenuators
- Mixing section
Define required:
Plot on fan curve:
BHP = (CFM × TSP) / (6356 × η_fan)
η_fan = fan total efficiency (0.65-0.85)
Motor HP = BHP / η_motor × Safety Factor
Safety factors:
- < 5 HP: 1.25
- 5-20 HP: 1.15
- > 20 HP: 1.10
Calculate sound power:
| Component | Typical ΔP (in. w.g.) |
|---|---|
| 2" pleated filter (clean) | 0.15-0.25 |
| 2" pleated filter (dirty) | 0.5-1.0 |
| 12" bag filter (clean) | 0.20-0.30 |
| HEPA filter | 0.5-1.5 |
| Cooling coil (6-row) | 0.4-0.6 |
| Heating coil (1-row) | 0.05-0.10 |
| Mixing section | 0.05-0.15 |
| Dampers (open) | 0.02-0.05 |
| Transitions | 0.05-0.10 |
Calculate based on:
For speed changes:
CFM₂/CFM₁ = RPM₂/RPM₁
SP₂/SP₁ = (RPM₂/RPM₁)²
BHP₂/BHP₁ = (RPM₂/RPM₁)³
For size changes (geometrically similar):
CFM₂/CFM₁ = (D₂/D₁)³
SP₂/SP₁ = (D₂/D₁)²
BHP₂/BHP₁ = (D₂/D₁)⁵
Multiple smaller fans vs. single large fan:
| Aspect | Array | Single |
|---|---|---|
| Redundancy | Built-in | Requires N+1 |
| Efficiency | Often higher | Peak only at design |
| Sound | Lower | Higher |
| Footprint | May be larger | Compact |
| Cost | Similar or lower | Varies |
| Control | Superior (staging) | VFD only |
Read from:
state/psychro.json: CFM, conditionsstate/concept.json: Configurationstate/coils.json: Coil pressure dropsstate/constraints.json: External SP, sound limitsWrite to state/fans.json:
{
"design_id": "from concept",
"system_analysis": {
"internal_sp_in_wg": {
"filters_clean": 0.35,
"filters_dirty": 0.85,
"cooling_coil": 0.45,
"heating_coil": 0.08,
"mixing_section": 0.10,
"dampers": 0.04,
"transitions": 0.08,
"total_clean": 1.10,
"total_dirty": 1.60
},
"external_sp_in_wg": 2.0,
"total_sp_design_in_wg": 3.60
},
"fans": [
{
"tag": "SF-1",
"type": "plenum",
"quantity": 1,
"manufacturer": "Greenheck",
"model": "PLR-24",
"performance": {
"cfm": 21000,
"tsp_in_wg": 3.6,
"rpm": 1450,
"bhp": 18.5,
"efficiency_percent": 72
},
"motor": {
"hp": 25,
"efficiency_percent": 93.6,
"voltage": 460,
"phase": 3,
"enclosure": "TEFC"
},
"vfd": {
"included": true,
"hp": 25,
"bypass": false
},
"acoustics": {
"sound_power_db": {
"63Hz": 92,
"125Hz": 89,
"250Hz": 85,
"500Hz": 81,
"1kHz": 77,
"2kHz": 73,
"4kHz": 69,
"8kHz": 65
},
"discharge_nc": 45
},
"dimensions": {
"wheel_diameter_in": 24,
"width_in": 36,
"height_in": 36,
"length_in": 48
}
}
],
"totals": {
"total_bhp": 18.5,
"total_motor_hp": 25,
"motor_kw": 18.6
}
}