一键导入
epd-to-spec
Generate CSI-formatted specification sections requiring EPDs and setting maximum GWP thresholds. References ISO 14025, ISO 21930, EN 15804.
用 Codex 或 Claude 帮你安装 复制这段 Prompt,粘贴到 Codex、Claude 或其他助手里,让它检查 Skill 页面并帮你完成安装。
菜单
Generate CSI-formatted specification sections requiring EPDs and setting maximum GWP thresholds. References ISO 14025, ISO 21930, EN 15804.
用 Codex 或 Claude 帮你安装 复制这段 Prompt,粘贴到 Codex、Claude 或其他助手里,让它检查 Skill 页面并帮你完成安装。
基于 SOC 职业分类
Look up ACRIS property transaction records for any NYC property — deeds, mortgages, satisfactions, liens, and ownership history. Use when the user asks who owns a building, when it last sold or for how much, or whether there are mortgages or liens against it. NYC only; for permits or violations use the DOB skills.
Look up Board of Standards and Appeals (BSA) variances and special permits for any NYC property. Use when checking whether a lot carries zoning relief — variances, special permits, appeals — that modifies its as-of-right envelope. NYC only; for base zoning controls use /zoning-analysis-nyc.
Look up DOB permit and job filing history for any NYC building — new-building, alteration, and demolition filings with status and dates. Use when the user asks what work was filed or permitted at an address, or to gauge renovation history during due diligence. NYC only; for open violations use /nyc-dob-violations.
Look up open and resolved DOB and ECB violations for any NYC building, with class, status, and penalty detail. Use when the user asks whether a building has violations, stop-work orders, or outstanding ECB penalties. NYC only; for housing-code violations use /nyc-hpd.
Look up HPD violations, complaints, and building registration for residential buildings.
Check if a NYC building is landmarked or in a historic district using LPC data.
| name | epd-to-spec |
| description | Generate CSI-formatted specification sections requiring EPDs and setting maximum GWP thresholds. References ISO 14025, ISO 21930, EN 15804. |
| allowed-tools | ["Read","Write","Edit","Bash","Glob","Grep","AskUserQuestion","mcp__google-sheets__get_sheet_data","mcp__google-sheets__list_sheets"] |
Takes EPD data, GWP limits, or a materials list and generates CSI-formatted specification sections that require Environmental Product Declarations and set maximum Global Warming Potential thresholds. Output follows the same three-part CSI SectionFormat used by /spec-writer.
If PROJECT.md exists in the working directory, read it before fetching — the Decisions index may already hold GWP threshold or material choices the spec must reflect. After completing, append chosen thresholds to its Code section. Update values in place (the dossier holds current state, not history), every entry with a source and date. A GWP threshold is a decision — if one was set here, propose recording it with /decision. No PROJECT.md? Skip silently — or mention /project-dossier init if the user is clearly starting a project.
The user provides one or more of:
If the user invokes the skill without input, ask:
Map materials to the correct division. EPD requirements are most relevant for structural, envelope, and interior finish materials:
| Division | Title | Common EPD Products |
|---|---|---|
| 03 30 00 | Cast-in-Place Concrete | Ready-mix concrete |
| 03 40 00 | Precast Concrete | Precast panels, structural precast |
| 03 41 00 | Precast Structural Concrete | Precast beams, columns |
| 05 12 00 | Structural Steel Framing | Hot-rolled steel, HSS |
| 05 21 00 | Steel Joist Framing | Open web steel joists |
| 05 31 00 | Steel Decking | Composite floor deck, roof deck |
| 05 50 00 | Metal Fabrications | Miscellaneous metals, rebar |
| 06 10 00 | Rough Carpentry | Dimensional lumber, engineered wood |
| 06 17 00 | Shop-Fabricated Structural Wood | Glulam, CLT, LVL |
| 07 21 00 | Thermal Insulation | Mineral wool, XPS, EPS, spray foam |
| 07 27 00 | Air Barriers | Fluid-applied, sheet membranes |
| 07 42 00 | Wall Panels | Metal wall panels, ACM |
| 07 54 00 | Thermoplastic Membrane Roofing | TPO, PVC |
| 08 44 00 | Curtain Wall / Glazing | Aluminum curtain wall, IGUs |
| 09 21 00 | Plaster and Gypsum Board | Gypsum board, joint compound |
| 09 30 00 | Tiling | Porcelain, ceramic tile |
| 09 51 00 | Acoustical Ceilings | ACT, mineral fiber |
| 09 65 00 | Resilient Flooring | LVT, rubber, linoleum |
| 09 68 00 | Carpeting | Carpet tile, broadloom |
| 32 12 00 | Asphalt Paving | HMA, WMA |
Read the user's input and build an inventory:
If the user provided EPD sheet data or a comparison report, extract the GWP values and declared units from there.
If no GWP thresholds are specified, do not use approximate baselines. Instead, ask the user:
"I need GWP thresholds to write the spec. You can provide them by:
/epd-research — I'll find EPDs for your material categories/epd-compare — compare products and pick a threshold from the resultsWe're working on EC3 API integration that will automate baseline lookups — for now, provide an EPD or a specific threshold."
Do not fall back to hardcoded numbers. Write the spec with [THRESHOLD TBD] placeholders if the user asks to proceed without data, and flag every placeholder clearly.
Report the mapping:
Identified X materials across Y divisions:
- 03 30 00 Cast-in-Place Concrete: GWP max 350 kg CO2e/m3
- 05 12 00 Structural Steel Framing: GWP max 1.16 kg CO2e/kg [VERIFY THRESHOLD]
- 07 21 00 Thermal Insulation: GWP max 1.2 kg CO2e/kg [VERIFY THRESHOLD]
Ask: "Does this mapping look correct? Any thresholds to adjust?"
For each material, write a three-part outline spec. The EPD-specific language is concentrated in Part 1 (submittals, quality assurance, sustainability) and Part 2 (environmental performance requirements).
1.01 Section Includes Standard scope of work for the material. No EPD-specific changes.
1.02 Related Sections Standard cross-references. Add:
1.03 References Standard material references PLUS:
1.04 Submittals Add the following to standard submittal requirements:
D. Environmental Product Declarations:
1. Submit product-specific Type III Environmental Product Declaration (EPD)
conforming to ISO 14025 and ISO 21930.
2. EPD shall be published by a program operator accredited per ISO 14025,
including but not limited to: UL Environment, NSF International,
SCS Global Services, Environdec (International EPD System), IBU, or
ASTM International.
3. EPD shall be current and valid at the time of submittal. Expired EPDs
are not acceptable.
4. EPD shall be third-party verified by an independent verifier approved
by the program operator.
5. Industry-average or sector EPDs are acceptable only when a product-specific
EPD is not available for the specified product category. Submit documentation
demonstrating unavailability.
6. EPD shall report environmental impacts for life cycle stages A1 through A3
(raw material supply, transport to manufacturer, manufacturing) at minimum.
1.05 Quality Assurance Add:
C. Environmental Performance Verification:
1. Manufacturer shall demonstrate that the supplied product meets the maximum
GWP thresholds specified in Part 2.
2. If the product is sourced from a different manufacturing plant than the one
covered by the submitted EPD, provide documentation that the EPD is
representative of the actual production facility.
1.06 Sustainability Requirements (new article — add if not already in the section)
A. Environmental Product Declaration Requirements:
1. Provide products with Type III Environmental Product Declarations meeting
the requirements of Article 1.04.D.
2. Maximum Global Warming Potential (GWP):
a. [Product]: [VALUE] kg CO2e per [DECLARED UNIT], measured for life cycle
stages A1 through A3.
3. GWP shall be calculated in accordance with ISO 21930 and reported using
characterization factors from IPCC AR5 or later.
B. LEED Documentation (if applicable):
1. Provide EPD documentation in format required for LEED v4.1 MRc2 credit
submission.
2. Coordinate with Owner's LEED consultant for documentation requirements.
1.07 Delivery, Storage, and Handling Standard. No EPD-specific changes.
1.08 Warranty Standard. No EPD-specific changes.
2.01 Manufacturers Standard manufacturer list with "or approved equal" language. Add:
B. All manufacturers shall provide a current, valid Type III EPD meeting the
requirements of Article 1.04.D. Manufacturers unable to provide a conforming
EPD are not acceptable.
2.02 Materials/Products Standard material specifications. No EPD-specific changes.
2.03 Environmental Performance Requirements (new article)
A. Maximum Global Warming Potential (GWP):
1. [Product]: Maximum [VALUE] kg CO2e per [DECLARED UNIT], for life cycle
stages A1 through A3 (raw material supply, transport, manufacturing).
2. GWP value shall be as reported in the product-specific EPD submitted
under Article 1.04.D.
B. Additional Environmental Performance (if applicable):
1. Recycled Content: Minimum [VALUE] percent by weight, post-consumer and
pre-consumer combined.
2. Regional Materials: Preference shall be given to products manufactured
within [DISTANCE] miles of the project site.
2.04 Finishes Standard. No EPD-specific changes.
2.05 Accessories Standard. No EPD-specific changes.
Standard execution language for the material. No EPD-specific additions. Follow the same pattern as /spec-writer:
If the user mentions LEED v4.1, add a dedicated LEED section at the end of the specification:
## Appendix — LEED v4.1 MRc2: Building Product Disclosure and Optimization
### Option 1 — Environmental Product Disclosure (1 point)
Use at least 20 permanently installed products sourced from at least five different
manufacturers that have Type III EPDs conforming to ISO 14025.
Products with product-specific EPDs: 1 product = 1 product count
Products with industry-wide (generic) EPDs: 1 product = 0.5 product count
### Option 2 — Environmental Product Optimization (up to 2 points)
Products that demonstrate impact reduction below baseline:
- Products with EPDs showing impact reduction compared to industry average
earn additional credit
- Third-party verified product-specific EPDs preferred
- Whole-building life cycle assessment (WBLCA) per ISO 14044 may be used
as an alternative compliance path
### Documentation Requirements
1. Maintain a product EPD log tracking all qualifying products
2. For each product, document: manufacturer, product name, EPD registration
number, program operator, GWP (A1-A3), and declared unit
3. Submit EPD log to LEED reviewer as part of MRc2 credit documentation
Apply [REVIEW REQUIRED] flags when:
Apply [VERIFY THRESHOLD] flags when:
Compile all sections into a single .md file organized by division number.
Default output path: ./epd-specs-[project-slug].md
[project-slug] from the project name or type (lowercase, hyphenated)epd-specs-draft.md./deliverables/File structure:
# EPD Specifications — [Project Name]
Generated: [date]
Project Type: [type]
Divisions: [count]
Sections: [count]
LEED Target: [if applicable]
---
## Division 03 — Concrete
### Section 03 30 00 — Cast-in-Place Concrete
#### Part 1 — General
...
#### Part 2 — Products
...
#### Part 3 — Execution
...
---
## Division 05 — Metals
### Section 05 12 00 — Structural Steel Framing
...
After writing the file, report:
EPD specifications written: X sections across Y divisions
Output: [file path]
GWP thresholds set:
- 03 30 00 Concrete: 350 kg CO2e/m3
- 05 12 00 Steel: 1.16 kg CO2e/kg [VERIFY THRESHOLD]
Sections flagged for review: [count]
- [list flagged sections]
/epd-research, or state a specific threshold. If the user asks to proceed without data, use [THRESHOLD TBD] placeholders and flag every one..md specification files./spec-writer for complete specs. This skill adds EPD/sustainability requirements to specific sections. The general /spec-writer produces full outline specs without EPD language. For a complete specification package, use both.