| name | simulink-interactions |
| description | Interact with a Simulink model currently open in MATLAB via the MATLAB MCP server. Use this skill whenever the user asks to inspect, modify, query, or navigate a Simulink model that is open in MATLAB — for example changing block properties, finding blocks, adding blocks, connecting signals, or navigating model hierarchy. Trigger whenever the user refers to "this model", "this block", "this subsystem", "selected blocks", or asks to do anything to a Simulink model without specifying a file path to open. Also trigger for requests like "change the gain", "color all sum blocks", "find all integrators", or any other operation on an already-open model. |
Simulink Open Model Interaction
This skill defines conventions for interacting with the Simulink model currently open in MATLAB, using mcp__matlab__evaluate_matlab_code as the primary tool.
Tooling Fallback
If the MATLAB MCP tool is unavailable in the current session but the user explicitly asks for real model creation or modification, fall back to local MATLAB execution such as matlab -batch. State the fallback briefly and keep the workflow identical: inspect, modify, verify, save.
Step 1: Resolve References
Before doing anything, determine what model/system/block(s) the user is referring to.
| User says | Resolution |
|---|
| "this model" | bdroot(gcs) |
| "this system" / "this subsystem" | gcs |
| "this block" | gcb |
| "selected blocks" (plural) | see snippet below |
| "all [Type] blocks in this subsystem" | see snippet below |
| "all [Type] blocks in the model" | see snippet below |
Selected blocks (plural)
opts = Simulink.FindOptions;
opts.SearchDepth = 1;
blks = getfullname(Simulink.findBlocks(gcs, 'Selected', 'on', opts));
All blocks of a specific type in the current subsystem
opts = Simulink.FindOptions;
opts.SearchDepth = 1;
BlockType = 'Gain'; % replace with actual type
blks = getfullname(Simulink.findBlocksOfType(gcs, BlockType, opts));
All blocks of a specific type in the entire model
BlockType = 'Gain'; % replace with actual type
blks = getfullname(Simulink.findBlocksOfType(bdroot, BlockType));
Step 2: Inspect Before Modifying
Use get_param to read current state before making changes. This helps you confirm you have the right block and understand its current configuration.
get_param(gcb, 'Gain') % read a specific parameter
get_param(gcb,'DialogParameters') % list all dialog parameters
get_param(gcb, 'ObjectParameters') % list all available parameters
Step 3: Apply Changes
Use set_param for most property changes:
set_param(gcb, 'Gain', '2')
set_param(gcb, 'BackgroundColor', 'red')
For bulk operations on multiple blocks, iterate over the blks cell array:
for i = 1:numel(blks)
set_param(blks{i}, 'BackgroundColor', 'yellow');
end
Adding Blocks
When adding blocks, follow these rules:
- Never pass a
'Position' argument to add_block
- Never use
set_param(blk, 'Position', ...) or set_param(blk, 'Location', ...)
- Never use
Simulink.BlockDiagram.arrangeSystem
- Use
getBlockPosition and setBlockDimensions (bundled in utils/) for all positioning
- To read block size, use
getBlockDimensions; to resize, use setBlockDimensions
- Add blocks one at a time: add a block, connect it, then position it relative to existing blocks before proceeding to the next
Utility signatures (see utils/ for full source):
[x, y] = getBlockPosition(block) % top-left corner
[width, height] = getBlockDimensions(block) % block size
setBlockPosition(block, x, y) % move, preserving size
setBlockDimensions(block, width, height) % resize, preserving top-left
Never use set_param(block, 'Position', ...) — always use setBlockPosition and/or setBlockDimensions instead.
% Example: add a Gain block to the right of the current block
modelName = bdroot(gcs);
refBlk = gcb;
% 1. Get reference block geometry
[refX, refY] = getBlockPosition(refBlk);
[refW, ~] = getBlockDimensions(refBlk);
% 2. Add block (no position argument)
newBlk = [modelName '/MyGain'];
add_block('built-in/Gain', newBlk);
% 3. Position it to the right of the reference block
gap = 50;
setBlockPosition(newBlk, refX + refW + gap, refY);
% 4. Connect it
Simulink.connectBlocks(Source,Destination);
Programmatic MATLAB Function Blocks
When editing a MATLAB Function block programmatically, do not assume set_param(block,'Script',...) exists. For MATLAB Function blocks, update the script through MATLABFunctionConfiguration:
blk = 'model/MyMATLABFunction';
cfg = get_param(blk, 'MATLABFunctionConfiguration');
cfg.FunctionScript = sprintf([ ...
'function y = fcn(u)\n' ...
'%%#codegen\n' ...
'y = 2*u;\n' ...
'end\n']);
If the function body references workspace parameters such as Kp, tau_sys, or Q_max, explicitly create Stateflow.Data entries with Scope = 'Parameter' or Simulink may fail size/type inference during compile:
rt = sfroot;
machine = rt.find('-isa', 'Stateflow.Machine', 'Name', bdroot(blk));
chart = machine.find('-isa', 'Stateflow.EMChart', 'Path', blk);
param = Stateflow.Data(chart);
param.Name = 'Q_max';
param.Scope = 'Parameter';
Without this explicit parameter declaration, a programmatically generated MATLAB Function block can fail with errors like "cannot determine output size/type" even when the same code works interactively.
Common built-in library paths:
built-in/Gain
built-in/Product
built-in/Constant
built-in/Scope
built-in/Subsystem
Exception for Inport and Outport use:
sprintf('simulink/Ports &\nSubsystems/In1')
sprintf('simulink/Ports &\nSubsystems/Out1')
Exception for Sum. Never use the Sum block, always use Add or Subtract instead:
sprintf(['simulink/Math\nOperations/Add'])
sprintf(['simulink/Math\nOperations/Subtract'])
Connecting Blocks
Always use Simulink.connectBlocks to connect blocks — never add_line. This API is more robust and handles port resolution automatically.
% Connect two blocks (Simulink picks the appropriate ports)
Simulink.connectBlocks(srcBlock, dstBlock);
% Connect specific ports when needed
Simulink.connectBlocks([srcBlock '/1'], [dstBlock '/1']);
Signal Logging
When the user asks to log a signal, use Simulink's built-in signal logging on the port directly. Never use a To Workspace block or a To File block.
% Log the first output port of a block
ph = get_param(gcb, 'PortHandles');
set(ph.Outport(1), 'DataLogging', 'on');
% Set the name lf the logged signal
set(ph.Outport(1), 'DataLoggingNameMode', 'SignalName');
set(ph.Outport(1), 'Name', 'mySignalName');
To log a specific block by path instead of gcb:
ph = get_param('modelName/BlockName', 'PortHandles');
set(ph.Outport(1), 'DataLogging', 'on');
After simulation, logged signals are accessible via logsout in the SimulationOutput object (when using sim()) or via Simulink.SimulationData.Dataset.
If the user explicitly asks for To Workspace blocks or named workspace artifacts as deliverables, follow the user's request. The "never use To Workspace" rule is only the default when the user asks to log signals and does not constrain the export mechanism.
Creating Subsystems
When adding a group of related blocks that should live inside a subsystem, add and connect all the blocks first (following the iterative one-at-a-time workflow above), then group them into a subsystem at the end:
% Collect handles of all blocks to group
blocks = [get_param('model/Block1', 'Handle'), ...
get_param('model/Block2', 'Handle'), ...
get_param('model/Block3', 'Handle')];
% Group into a subsystem — Simulink handles port creation automatically
Simulink.BlockDiagram.createSubsystem(blocks);
createSubsystem automatically adds the necessary Inport/Outport blocks inside the subsystem and rewires external connections. Do not manually create a Subsystem block and move blocks into it.
Clearing a Subsystem
Simulink.BlockDiagram.deleteContents only accepts a block diagram, not an arbitrary subsystem path. If you need to rebuild a subsystem in place, delete its lines and child blocks manually:
subsys = 'model/MySubsystem';
lines = find_system(subsys, 'FindAll', 'on', 'SearchDepth', 1, 'Type', 'line');
if ~isempty(lines)
delete_line(lines);
end
blocks = find_system(subsys, 'SearchDepth', 1, 'Type', 'Block');
blocks = setdiff(blocks, {subsys}, 'stable');
for i = 1:numel(blocks)
delete_block(blocks{i});
end
This is the safe pattern when regenerating subsystem internals from a script.
Step 4: Verify
After making changes, confirm success by reading back the modified parameter or reporting what was changed.