一键导入
dcb0129-hazard-log
Use when generating a clinical safety hazard log, clinical risk matrix, or DCB0129 Clinical Safety Case Report for an NHS digital health service.
用 Codex 或 Claude 帮你安装 复制这段 Prompt,粘贴到 Codex、Claude 或其他助手里,让它检查 Skill 页面并帮你完成安装。
菜单
Use when generating a clinical safety hazard log, clinical risk matrix, or DCB0129 Clinical Safety Case Report for an NHS digital health service.
用 Codex 或 Claude 帮你安装 复制这段 Prompt,粘贴到 Codex、Claude 或其他助手里,让它检查 Skill 页面并帮你完成安装。
基于 SOC 职业分类
Use when deploying an NHS Python/FastAPI service to Azure using Terraform, or configuring App Service, Key Vault, or Application Insights.
Use when scaffolding or building an NHS service with the FastAPI + React + Azure stack. Contains project structure, scaffold steps, and deployment commands.
Use when assessing a feature or PR against the GDS Service Standard 14 points, or producing NHS Alpha service assessment evidence.
Use when documenting architectural decisions for an NHS digital service using the ADR format, or when reviewing technology choices for GDS assessment evidence.
Use when drafting a Data Protection Impact Assessment (DPIA) for an NHS service that processes health data under UK GDPR.
Use when generating synthetic NHS test data including NHS numbers, patient names, SNOMED codes, and seed scripts for development and demos.
| name | dcb0129-hazard-log |
| description | Use when generating a clinical safety hazard log, clinical risk matrix, or DCB0129 Clinical Safety Case Report for an NHS digital health service. |
This skill generates clinical safety documentation following the DCB0129 standard for NHS digital health services, using the SIREN methodology for hazard identification.
Identify hazards across these categories:
| Category | Examples |
|---|---|
| System | System unavailability, data loss, incorrect data display |
| Information | Wrong patient data shown, stale clinical data, missing alerts |
| Risk | Misidentification of patients, delayed referrals, incorrect dosage display |
| Error | User input errors not caught, misleading UI, ambiguous clinical terms |
| New | Hazards introduced by new technology, integration points, workarounds |
| Severity ↓ / Likelihood → | Very Low | Low | Medium | High | Very High |
|---|---|---|---|---|---|
| Catastrophic (death) | 3 | 4 | 5 | 5 | 5 |
| Major (permanent harm) | 2 | 3 | 4 | 5 | 5 |
| Considerable (semi-permanent) | 2 | 3 | 3 | 4 | 5 |
| Significant (short-term harm) | 1 | 2 | 3 | 3 | 4 |
| Minor (inconvenience) | 1 | 1 | 2 | 2 | 3 |
Risk levels: 1 = Acceptable, 2 = Acceptable with monitoring, 3 = Undesirable — needs mitigation, 4 = Mandatory mitigation, 5 = Unacceptable — must eliminate
The agent must create new files:
docs/clinical-safety/hazard-log.mddocs/clinical-safety/safety-case-report.mdUse the structure described above as guidance. Do not edit this skill file — it is a reference, not a template to fill in.