- Division 10 specialty items for construction - toilet partitions, accessories, lockers, signage, fire protection, operable partitions, and coordination.
# Division 10 Specialties - Construction Management Guide
This skill provides expert-level guidance for construction project managers and field supervisors on Division 10 specialty items including toilet partitions, toilet accessories, lockers, signage, fire protection specialties, operable partitions, flagpoles, and miscellaneous specialties.
## Quick Reference Tables
### Division 10 Major Categories
| Category | CSI Section | Key Items | Typical Lead Time |
|----------|-------------|-----------|-------------------|
| Toilet Partitions | 10 21 13 | Metal, plastic laminate, solid plastic, phenolic, stainless steel partitions | 8-12 weeks |
| Toilet Accessories | 10 28 00 | Grab bars, dispensers, mirrors, baby changing stations | 4-6 weeks standard |
| Lockers | 10 51 00 | Metal, plastic, phenolic lockers; benches | 8-12 weeks |
| Shelving | 10 56 00 | Metal shelving, high-density mobile systems | 4-6 weeks standard; 10-14 weeks mobile |
| Fire Protection Specialties | 10 44 00 | Fire extinguisher cabinets | 4-6 weeks |
| Signage | 10 14 00 | ADA signage, wayfinding, directories | 6-14 weeks |
| Wall Protection | 10 26 00 | Corner guards, crash rails, wall panels | 4-6 weeks |
| Visual Display | 10 11 00 | Marker boards, tack boards, display cases | 4-6 weeks standard |
| Operable Partitions | 10 22 00 | Accordion, panel/track, glass partitions | 10-16 weeks |
| Flagpoles | 10 75 00 | Ground-set, wall-mounted flagpoles | 8-12 weeks |
| Postal Specialties | 10 55 00 | Mailboxes, parcel lockers | 8-12 weeks + USPS approval |
### Toilet Partition Material Selection
| Material | Moisture Resistance | Durability | Cost | Best Application |
|----------|---------------------|------------|------|------------------|
| Powder-Coated Steel | Low | Medium (dents) | Economy | Office, light commercial |
| Plastic Laminate | Low | Medium | Mid-range | Office, retail |
| Solid Plastic (HDPE) | Excellent | Excellent | Mid-high | Schools, recreation, pools |
| Phenolic | Excellent | Excellent | High | Airports, stadiums, healthcare |
| Stainless Steel | Excellent | Excellent | Premium | High-end, institutional |
### Toilet Partition Mounting Types
| Type | Description | Floor Anchoring | Overhead Bracing | Best Use |
|------|-------------|-----------------|------------------|----------|
| Floor-Mounted/Overhead-Braced | Pilasters anchored to floor with overhead brace | Yes | Yes | Most common, standard commercial |
| Ceiling-Hung | Suspended from structure above | No | Hung from ceiling | Easy floor cleaning, modern look |
| Floor-to-Ceiling | Full-height pilasters and panels | Yes | Head rail at ceiling | Maximum privacy |
| Floor-Mounted Only | Pilasters anchored to floor only | Yes | No | Limited applications |
### Fire Extinguisher Placement Requirements
| Hazard Class | Examples | Max Travel Distance | Typical Extinguisher |
|--------------|----------|---------------------|----------------------|
| Class A | Paper, wood, cloth | 75 feet | ABC multi-purpose |
| Class B | Flammable liquids | 50 feet | ABC or BC |
| Class C | Electrical | Per A or B | CO2 or ABC |
| Class D | Combustible metals | 75 feet | Specialty agent |
| Class K | Cooking oils | 30 feet | Wet chemical |
### ADA Mounting Height Summary
| Item | Mounting Height | Additional Requirements |
|------|-----------------|------------------------|
| Grab Bars | 33"-36" AFF to centerline | 1½" clearance from wall, 250 lb capacity |
| Toilet Paper Holder | 15"-48" AFF | 7"-9" from front of toilet |
| Soap Dispenser | 48" max to operable parts | Forward reach |
| Paper Towel Dispenser | 48" max to operable parts | Forward reach |
| Hand Dryer | 48" max AFF | Max 4" projection if 27"-80" AFF |
| Mirror (above lavatory) | 40" max AFF to bottom of reflection | - |
| Coat Hook (accessible) | 48" max AFF | In accessible compartments |
| Baby Changing Station | Accessible reach range | When provided |
| Fire Extinguisher Cabinet | Top handle ≤5' AFF (≤40 lb unit) | Max 4" projection if 27"-80" AFF |
| Tactile Signage | 48"-60" AFF to baseline | 18"x18" clear floor space |
### Operable Partition Acoustic Ratings
| STC Rating | Privacy Level | Typical Applications |
|------------|---------------|---------------------|
| 35-42 | Basic speech privacy | Economy dividers |
| 45-50 | Good speech privacy | Standard commercial |
| 51-56 | Excellent speech privacy | Conference rooms, hotels |
| 56+ | Maximum isolation | Premium applications |
### Long-Lead Item Summary
| Item | Lead Time | Early Coordination Needed |
|------|-----------|---------------------------|
| Operable Partitions | 10-16 weeks | Structural header design |
| Custom Signage | 8-14 weeks | Design approval |
| Toilet Partitions (specialty) | 10-14 weeks | ADA layout |
| High-Density Mobile Shelving | 10-14 weeks | Floor loading |
| Custom Lockers | 12-16 weeks | Layout verification |
| Postal Equipment | 8-12 weeks + approval | USPS coordination |
## Reference Files
### Product Categories
- [Toilet Partitions](references/toilet-partitions.md) - Materials, mounting types, components, ADA requirements
- [Toilet Accessories](references/toilet-accessories.md) - Grab bars, dispensers, mirrors, mounting heights
- [Lockers & Shelving](references/lockers-shelving.md) - Locker types, metal shelving, mobile systems
- [Fire Extinguishers & Cabinets](references/fire-extinguishers-cabinets.md) - Types, placement, cabinets
- [Signage & Wayfinding](references/signage-wayfinding.md) - Signage types, wayfinding, digital
- [ADA Signage Requirements](references/ada-signage-requirements.md) - Tactile, Braille, mounting
- [Corner Guards & Wall Protection](references/corner-guards-wall-protection.md) - Protection systems
- [Visual Display Boards](references/visual-display-boards.md) - Marker boards, display cases, screens
- [Operable Partitions](references/operable-partitions.md) - Types, acoustics, structural coordination
- [Flagpoles & Postal](references/flagpoles-postal.md) - Flagpoles, mailboxes, USPS requirements
- [Miscellaneous Specialties](references/miscellaneous-specialties.md) - Mats, sun control, other items
### Project Management
- [Blocking & Coordination](references/blocking-coordination.md) - Blocking requirements, verification
- [Long-Lead Procurement](references/long-lead-procurement.md) - Lead times, milestones, tracking
- [Code Compliance](references/code-compliance.md) - ADA, fire code, building code
- [Coordination & Sequencing](references/coordination-sequencing.md) - Installation sequence, trades
- [Safety Hazards](references/safety-hazards.md) - Installation and specialty hazards
- [Specifications & CSI](references/specifications-csi.md) - Division 10 sections, bid packages
## Critical Coordination Points
### Pre-Drywall Requirements
1. **Blocking Installation** - All backing for accessories, grab bars, heavy items
2. **Framing for Recessed Items** - Fire extinguisher cabinets, display cases
3. **Electrical Rough-In** - Hand dryers, motorized screens, digital signage
4. **Operable Partition Headers** - Structural support verification
### After Drywall, Before Paint
1. Recessed cabinet frames
2. Entrance mat frames
3. Verify all blocking locations
### After Paint
1. Toilet partitions
2. Toilet accessories
3. Lockers and shelving
4. Fire extinguisher cabinets
5. Wall protection
6. Visual display boards
7. Most signage
### Final Phase
1. Operable partitions (after all finishes complete)
2. Final signage installation
3. Fire extinguisher installation
4. Final adjustments and punch list
## Related Skills
- **interior-finishes-trades** - Drywall coordination, blocking, finish sequencing
- **doors-frames-hardware** - Door protection, hardware coordination
- **fire-protection-systems** - Fire extinguisher requirements
- **electrical-systems** - Power for dryers, motorized screens, digital signage
- **quality-control-closeout** - Punch list and final inspection
- **procore-project-management** - Submittal tracking
- **construction-safety-management** - General safety requirements
## Common Issues and Solutions
### Toilet Partitions
| Issue | Cause | Solution |
|-------|-------|----------|
| Doors don't close properly | Floor not level, pilasters out of plumb | Check floor flatness, adjust pilasters and hardware |
| Grab bar mounting failed | No blocking installed | Install blocking before drywall; use toggle bolts as last resort |
| Partition rust at edges | Wrong material for wet area | Specify solid plastic or phenolic for wet areas |
### Accessories
| Issue | Cause | Solution |
|-------|-------|----------|
| Accessories pulling from wall | No blocking, poor anchors | Verify blocking pre-drywall; use proper anchors |
| ADA non-compliance | Wrong heights/locations | Reference ADA mounting requirements; verify layout |
| Hand dryer electrical issues | Circuit undersized | Verify dedicated circuit and voltage requirements |
### Operable Partitions
| Issue | Cause | Solution |
|-------|-------|----------|
| Panels don't seal properly | Floor/ceiling not flat, structure deflection | Check tolerances; adjust seals; verify structural support |
| Poor acoustics | Flanking paths, inadequate seals | Address ceiling plenum, verify seal engagement |
| Difficult operation | Track alignment, dirty track | Clean and align track; adjust panels |
### Signage
| Issue | Cause | Solution |
|-------|-------|----------|
| ADA non-compliance | Wrong character size, no Braille, wrong location | Review ADA requirements; relocate to latch side |
| Exit signs not illuminated | Power issue, lamp failure | Check circuit; replace lamps/LEDs |
| Wayfinding confusing | Poor design, inconsistent | Engage signage consultant; create standards |