ifc-errors-spatial-structure

النجوم٠
التفرعات٠
آخر تحديث٢٠ مايو ٢٠٢٦ في ٠٩:٠٩

Use when IFC elements do not appear in a viewer's model tree, are missing from quantity take-off or facility-management exports, or a buildingSMART validation report flags spatial-structure problems : orphan elements with no spatial container, one element contained in two places at once, an element placed at the wrong spatial level, a deprecated proxy used as a placeholder, or a missing or broken spatial tree. Prevents shipping orphan elements with no IfcRelContainedInSpatialStructure link, mislabelling double containment as a WR31 violation, attaching physical elements with IfcRelAggregates instead of IfcRelContainedInSpatialStructure, using IfcBuildingElementProxy as a void or clearance placeholder in IFC4.3, and building a spatial tree that never reaches IfcProject. Covers orphan-element detection, the IfcElement.ContainedInStructure SET [0:1] inverse, WR31 and WR41, the IfcProject NoDecomposition rule, the IfcSingleProjectInstance global rule, IfcRelReferencedInSpatialStructure for multi-storey elements,