| name | indicator-catalog |
| description | Create and register indicator catalog entries for automation. Use for Catalog.cs files, CatalogListingBuilder patterns, parameter/result definitions, and PopulateCatalog registration. |
Indicator catalog development
File
src/Indicators/{category}/{Indicator}/{Indicator}.Catalog.cs
Builder pattern
public static partial class Ema
{
internal static readonly IndicatorListing CommonListing =
new CatalogListingBuilder()
.WithName("Exponential Moving Average")
.WithId("EMA")
.WithCategory(Category.MovingAverage)
.AddParameter<int>("lookbackPeriods", "Lookback Period",
description: "Number of periods for the EMA calculation",
isRequired: true, defaultValue: 20, minimum: 2, maximum: 250)
.AddResult(nameof(EmaResult.Ema), "EMA", ResultType.Default, isReusable: true)
.Build();
internal static readonly IndicatorListing SeriesListing =
new CatalogListingBuilder(CommonListing)
.WithStyle(Style.Series)
.WithMethodName("ToEma")
.Build();
internal static readonly IndicatorListing StreamListing =
new CatalogListingBuilder(CommonListing)
.WithStyle(Style.Stream)
.WithMethodName("ToEmaHub")
.Build();
internal static readonly IndicatorListing BufferListing =
new CatalogListingBuilder(CommonListing)
.WithStyle(Style.Buffer)
.WithMethodName("ToEmaList")
.Build();
}
Method naming
| Style | Pattern | Example |
|---|
| Series | To{Name} | ToEma |
| Stream | To{Name}Hub | ToEmaHub |
| Buffer | To{Name}List | ToEmaList |
.WithMethodName() must be in style-specific listings, NOT in CommonListing.
IndicatorListing.ResultRecordType is derived from the method name when the listing is built — do not set it by hand and do not add a builder method for it. Naming a method of the wrong style (e.g. ToEma on the Buffer listing) makes it report the wrong result shape.
Parameter patterns
AddParameter<T>() — primitive value types (typically int or double)
AddEnumParameter<T>() — enum types
AddDateParameter() — DateTime
AddSeriesParameter() — IReadOnlyList<T> where T : IReusable
minimum and maximum required for all numeric parameters
parameterName must match the bound method's parameter name exactly — a mismatch makes a catalog-bound caller silently receive the default instead of the value it supplied
- Declare parameters as an unbroken run in signature order, skipping none in the middle;
ListingExecutor binds them positionally and picks an overload by argument count
isRequired: false must mean omitting the argument yields defaultValue — so use it only when the parameter has a C# default equal to defaultValue, or when the listing declares no defaultValue at all and promises nothing (VWAP startDate). When the argument can only be dropped by selecting a shorter overload that behaves differently while a defaultValue is advertised — ToPrs(sourceEval, sourceBase) computes no PrsPercent — use isRequired: true, and reach the shorter form with WithoutParam(name) at execution time
Result patterns
dataName uses nameof(TResult.Property), not a string literal, so a renamed result property fails the build instead of a test — e.g. .AddResult(nameof(EmaResult.Ema), "EMA", ...)
displayName stays a string literal; it is a human label, not a member name
isReusable: true only for the property mapping to IReusable.Value
ISeries models: all results must have isReusable: false
- Exactly one
isReusable: true per IReusable indicator
Categories
| Category | Examples |
|---|
CandlestickPattern | Doji, Marubozu |
MovingAverage | EMA, SMA, HMA, TEMA, WMA, DEMA |
Oscillator | RSI, Stochastic, MACD, CCI, BOP, CMO, Chop, DPO |
PriceChannel | Bollinger Bands, Keltner, Donchian, VWAP |
PriceCharacteristic | ATR, Beta, Standard deviation, True Range |
PricePattern | Fractal, Pivot Points |
PriceTransform | Bar Part, ZigZag |
PriceTrend | ADX, Aroon, Alligator, AtrStop, SuperTrend, Vortex |
StopAndReverse | Chandelier, Parabolic SAR, Volatility Stop |
VolumeBased | OBV, Chaikin Money Flow, Chaikin Oscillator |
Registration
Add entries inside the host repository's catalog populator method. The backing collection is a private static readonly List<IndicatorListing> declared at the top of the catalog file; the host repository determines its field name (shown below as listings).
Indicators are grouped alphabetically by indicator ID (abbreviation) and separated by a blank line. Each block is preceded by a short comment header — // {Abbreviation} ({Full Name}) when an abbreviation is conventional, otherwise just // {Full Name}. Within a block, the preferred order for the style listings is Buffer → Series → Stream:
listings.Add(Ema.BufferListing);
listings.Add(Ema.SeriesListing);
listings.Add(Ema.StreamListing);
listings.Add(Hma.BufferListing);
listings.Add(Hma.SeriesListing);
listings.Add(Hma.StreamListing);
Series-only indicators (no streamable variant) register a single SeriesListing line in the same alphabetical position; e.g.:
listings.Add(Beta.SeriesListing);
Prohibited
.WithMethodName() in CommonListing
- Wrong indicator method name
isReusable: true for ISeries models
- Multiple
isReusable: true results per indicator
- A
dataName as a string literal where nameof can reach the member
- A
parameterName that names a member the library does not have
isRequired: false with a defaultValue the C# signature does not apply when the argument is omitted
Testing
tests/Library/Indicators/{folder}/{Indicator}/{Indicator}CatalogTests.cs:
[TestClass]
public class EmaCatalogTests : TestBase
{
[TestMethod]
public void EmaSeriesListing()
{
var listing = Ema.SeriesListing;
listing.Name.Should().Be("Exponential Moving Average");
listing.Style.Should().Be(Style.Series);
listing.MethodName.Should().Be("ToEma");
}
}
tests/Library/Common/Catalog/Catalog.Binding.Tests.cs additionally enforces, for every
listing in the catalog, that MethodName resolves to a real method of the listing's own
style, that each dataName resolves to a property on that method's result record, and
that each parameterName forms a contiguous, in-order run in the signature. A listing
naming a member the library does not have fails there. It does not check parameter
types or value semantics, so keep writing the per-indicator test.