| name | neqsim-safety-function-coverage-screening |
| calculation_basis | screening |
| version | 0.1.0 |
| description | Educational process safety-function coverage screening using the public API RP 14C / ISO 10418 SAFE-chart concept. USE WHEN: a task needs a public, screening-level check of whether a process component has the typically required protective functions (PSH, PSL, PSV, LSH, LSL, etc.) before a formal SAFE-chart and safety analysis review. |
| last_verified | 2026-06-18 |
| requires | {"python_packages":[],"java_packages":[],"env":[],"network":[]} |
Safety Function Coverage Screening
Use this skill for public, educational safety-function coverage screening. It checks whether a process component declares the protective functions that API RP 14C and ISO 10418 typically associate with that component type, reports the missing functions, and gives a coverage ratio so an agent can flag gaps before a formal Safety Analysis Function Evaluation (SAFE) chart review.
When to Use
- When a user asks whether a vessel or component has the usual API RP 14C protective functions.
- When an agent needs a quick protective-function gap check to scope a safety review.
- When examples must run without confidential SAFE charts, cause-and-effect matrices, or company safety specs.
Inputs
component_type: one of pressure_vessel, separator, gas_pipeline_segment, liquid_pipeline_segment, fired_heater, compressor, pump, or wellhead.
provided_functions: a collection of declared protective-function codes (for example PSH, PSL, PSV, LSH, LSL, TSH, FSV, BSDV).
Outputs
component_type: the normalized component type.
required_functions: the typically required protective-function codes for that type.
provided_functions: the normalized declared functions.
missing_functions: required functions that were not declared.
coverage_ratio: fraction of required functions that are declared.
coverage_warning: ok, watch, or gap.
assumptions: public assumptions used by the placeholder model.
Engineering Method
The Python class SafetyFunctionCoverageModel uses the open API RP 14C / ISO 10418 concept only:
- each component type maps to a public set of typically required protective functions.
- the provided functions are compared to the required set to find missing functions.
- the coverage ratio is the count of provided required functions divided by the required count.
- the warning is a simple rule-based label that flags gaps for a formal review.
This is educational and screening-only logic. The required-function sets are simplified public defaults, not a project SAFE chart. It does not perform an undesirable-event analysis, evaluate detectable abnormal conditions, credit alternate protection, or assess independence and reliability. It is not a replacement for a formal API RP 14C / ISO 10418 SAFE-chart analysis and a qualified safety review.
Python Usage Pattern
from safety_function_coverage_screening import SafetyFunctionCoverageModel
model = SafetyFunctionCoverageModel()
result = model.evaluate(
component_type="separator",
provided_functions=["PSH", "PSL", "PSV", "LSH"],
)
print(result.coverage_warning)
print(result.missing_functions)
print(result.coverage_ratio)
Related NeqSim Functionality
This screening logic is also implemented as a validated NeqSim Java class so it can run inside a process model:
neqsim.process.safety.SafetyAnalysisFunctionEvaluation — API RP 14C / ISO 10418 SAFE-chart coverage evaluation: given a component type and provided protective functions, returns required vs provided functions, the missing list, and a coverage ratio.
neqsim.process.safety.barrier.BarrierRegister and SafetyCriticalElement — barrier management for the credited protective functions.
This skill is a public triage layer aligned with the NeqSim SafetyAnalysisFunctionEvaluation class.
Validation Checklist
Common Mistakes
| Symptom | Cause | Fix |
|---|
| Coverage looks complete but is not | Alternate or higher-level protection assumed | Use a formal SAFE chart to credit alternate protection |
| Wrong required set | Component type misclassified | Use the correct component type for the equipment |
| Missing function disputed | Local code or company practice differs | Defer to the applicable code and project safety basis |