| description | Interpret Bowties diagnostic reports from users. Knows what each field means, what absence of data implies at each session phase, and what to request next. Use when a user provides a diagnostic JSON (from issue, email, or clipboard) or when triaging connection/CDI/sync issues. Keywords: diagnostic, timeout, CDI, serial, SPROG, connection, debug, frame, ring buffer.
|
Diagnostic Report Analysis
When to invoke this skill
- A user provides a Bowties diagnostic report JSON (in an issue comment, email, or pasted)
- You are triaging a connection, CDI download, or config-read failure
- You need to understand what happened during a session based on the diagnostic snapshot
Tool requirement
Always use the lcc-trace MCP server tools for frame decoding and diagnostic analysis:
analyze_diagnostic โ pass the full report JSON for structured interpretation
decode_diagnostic_frames โ pass recentFrameActivity for frame-by-frame decoding
decode_frame โ decode individual frames when investigating specific messages
Use tool_search to load these tools before calling them. Only fall back to the manual
reference tables below if a tool call returns an error (not merely because the tables exist).
Step 0 โ Acquire the report
| How they give it | What to do |
|---|
| Pasted inline / issue comment | Extract the JSON block |
| Attached file | Read file |
| Multiple reports | Analyze each separately, then compare |
Step 1 โ Call analyze_diagnostic MCP tool
Pass the full JSON string as the report parameter. The tool returns:
- Session phase (just-connected / discovery-complete / cdi-failed / normal)
- Connection details (adapter, baud, flow control, device preset)
- Discovery summary (nodes found, probe timing)
- Error entries (phase, type, detail)
- Frame activity summary (TX/RX counts, time range)
- Anomalies (mismatches, timing issues)
- Suggested next steps
Only fall back to the manual reference tables in Step 2โ5 if the MCP tool returns an error.
Step 2 โ Determine session phase (manual fallback)
UX context for CDI vs config reads
"Read Configuration" is the user-facing action (button or sidebar dot). Internally it is a two-phase workflow:
- CDI XML download โ fetches the node's configuration schema (tracked in
cdiDownloads). Skipped when the CDI is already cached.
- Config value read โ reads actual field values from node memory using the CDI schema (tracked in
configReads).
The user never explicitly triggers "CDI download" โ it happens automatically as a prerequisite of "Read Configuration". Discovery only queries SNIP/PIP metadata; clicking a node in the sidebar only selects it.
Sidebar node indicators
The sidebar shows different indicators depending on node state. These help interpret what the user describes:
| Node state | Sidebar indicator | Meaning |
|---|
| Discovered but not yet saved in layout | [NEW] amber pill badge | Node found on bus but not persisted in saved layout |
| Saved in layout, config not yet read (online) | Amber clickable dot | Click triggers Read Configuration for that node |
| Config values have been read | Clean (no badge) | Fully read |
| Unsaved in-memory edits | Amber pending-edits dot | User changed values but hasn't saved |
| Saved offline edits pending apply | Teal pending-apply dot | Offline edits ready to write to node |
Key: [NEW] suppresses the not-read dot. A freshly discovered node shows [NEW], never the dot. The dot only appears for nodes already persisted in the saved layout whose config values haven't been read this session (e.g., after reopening a saved layout and reconnecting).
Neither indicator checks CDI cache status โ CDI availability is invisible to the sidebar and handled internally when Read Configuration runs.
Phase table
| Condition | Phase | Implication |
|---|
cdiDownloads: {} + errors: [] + eventRoleExchange: null | Just connected | Report captured before user clicked Read Configuration |
cdiDownloads: {} + errors has phase: "cdi-download" entries | CDI XML download failed | Real failure during CDI fetch โ analyze error details |
cdiDownloads has entries + configReads: {} | CDI XML downloaded, config not started | CDI fetch succeeded but config values not yet read (user may not have completed the Read Configuration flow, or the read phase failed) |
cdiDownloads has entries + configReads has entries | Normal session | Full Read Configuration flow completed successfully |
eventRoleExchange is non-null but cdiDownloads: {} | Post-event-roles | Connected and synced but user hasn't clicked Read Configuration yet |
Key insight: The diagnostic is a point-in-time snapshot. Empty fields mean "not happened yet" โ not necessarily "failed."
Step 3 โ Interpret discovery
| Field | Meaning | Anomaly |
|---|
probes[].nodesRespondedCount | Nodes that replied to that probe | Always 0 = known tracking bug (non-blocking) |
discovery.nodes[] | Nodes successfully identified | Empty despite frames in ring buffer = timing race (report captured too early) |
nodes[].msAfterConnect | When VerifiedNodeID arrived (ms after connect) | >2000ms = slow network or contention |
nodes[].snipQueryDurationMs | SNIP round-trip time | >500ms on serial = possible contention; 0 = SNIP answered from cache or pre-existing |
Step 4 โ Interpret errors
error_type | phase | Meaning | Likely cause |
|---|
"timeout" | "cdi-download" | No Memory Config reply within 5sร3 attempts | Node not responding to datagrams; CAN bus issue; alias stale |
"protocol-error" | "cdi-download" | Datagram rejected or malformed reply | Node firmware issue; wrong address space |
"timeout" | "config-read" | Config field read timed out | Same causes as CDI timeout |
"timeout" | "snip-query" | SNIP reply never arrived | Node offline or doesn't support SNIP |
Step 5 โ Decode frame activity
Call decode_diagnostic_frames with the recentFrameActivity array and (optionally) the discovery.nodes array as knownNodes.
Only if the MCP tool returns an error, decode manually using this reference:
Key frame identification (by header bits 28-24, i.e. first 2 hex digits of header)
| Top nibble (hex) | Frame type | Meaning |
|---|
19 | Standard MTI (global or addressed) | Most protocol messages |
1A | DatagramOnly | Single-frame datagram (CDI read request fits here: 7 bytes) |
1B | DatagramFirst | Multi-frame datagram start |
1C | DatagramMiddle | Multi-frame datagram continuation |
1D | DatagramFinal | Multi-frame datagram end |
10โ17 | CAN control (CID/RID/AMD/AME) | Alias negotiation / node startup |
Common MTI values (header >> 12, for non-datagram frames)
| MTI value | Name | What it means |
|---|
0x19490 | Verify Node ID Global | Discovery probe |
0x19170 | Verified Node ID | Node announcing its identity |
0x19828 | Protocol Support Inquiry | PIP query |
0x19668 | Protocol Support Reply | PIP answer |
0x19DE8 | SNIP Request | Simple Node Info query |
0x19A08 | SNIP Response | Simple Node Info reply (multi-frame addressed) |
0x19A28 | Datagram Received OK | ACK for a datagram |
0x19A48 | Datagram Rejected | NAK for a datagram |
What to look for in the ring buffer
- TX datagram frames present but no RX datagram reply โ Node not responding to memory config
- Only RX frames, no TX โ Bowties never sent requests (captured too early or connection issue)
- TX VerifyNodeGlobal (0x19490) โ Discovery probe was sent
- RX VerifiedNode (0x19170) โ Nodes responded to discovery
- SNIP reply frames (0x19A08) with multi-frame flags โ SNIP data flowing correctly
- No datagram frames at all โ Either CDI never attempted, or ring buffer only captured later traffic
Ring buffer caveats
- Fixed size (last ~50 frames) โ earlier activity is lost
timestampMs counts DOWN from report capture time (higher = older)
- If all frames share the same
timestampMs, they arrived in a burst
- Absence of frame types doesn't prove they were never sent โ only not in the buffer window
Addressed message body encoding
For standard addressed messages (MTI category addressed):
- Data bytes [0:1] = destination alias (big-endian, top 4 bits of byte 0 are flags)
- Remaining bytes = payload
- Multi-frame flag in byte 0:
0x10 = first, 0x30 = middle, 0x20 = last, 0x00 = only
Datagram header encoding
For datagram frames (top nibble 0x1Aโ0x1D):
- Header bits [23:12] = destination alias
- Header bits [11:0] = source alias
- ALL data bytes are payload (no dest in body)
Step 6 โ Formulate response
If phase = "just connected" (too early)
Tell the user:
"This diagnostic was captured before any configuration read was attempted.
To diagnose the failure, please:
- Connect to the serial port
- Wait for nodes to appear in the sidebar
- Click Read Configuration โ either the button shown when you select
a node, or the Read Remaining toolbar button for all unread nodes.
(If the node shows a
[NEW] badge, select it first, then click the
Read Configuration button that appears.)
- Wait for the error/timeout message to appear
- THEN copy the diagnostic report (โฎ menu โ Copy Diagnostic Report)"
Note: "Read Configuration" first downloads the CDI XML (if not cached),
then reads config values. The diagnostic tracks both phases separately.
If phase = "CDI XML download failed"
Analyze the error entries and frame buffer to determine:
- Were datagram request frames sent? (TX with header top nibble 0x1Aโ0x1D)
- Were DatagramReceivedOk (0x19A28) frames received? (means node ACK'd the request)
- Were any datagram reply frames received? (RX with matching aliases)
- Was DatagramReceivedOk sent but no reply datagram followed? (node processing timeout)
If phase = "CDI done, config not started"
The CDI XML was fetched successfully but config value reads haven't happened or failed:
- If
errors has phase: "config-read" entries โ config read failed; analyze those errors
- If
errors is empty โ user may not have completed the flow, or report was captured between phases
If comparing serial vs TCP
Key differences:
- TCP: GridConnect over TCP socket (reliable byte stream, no flow control issues)
- Serial: GridConnect over USB-serial (depends on baud rate, flow control, adapter firmware)
- Same protocol code in Bowties for both โ differences are at transport level
If comparing multiple reports
Look for patterns:
- Same failure across different nodes โ transport/bus issue, not node-specific
- Failure with one node but not others โ node firmware or config issue
- Works via TCP hub but not serial โ SPROG adapter or serial config issue
Step 7 โ Suggest next actions
Based on findings, suggest one of:
| Finding | Suggestion |
|---|
| Report too early | Capture post-failure diagnostic (after clicking Read Configuration and seeing the error) |
| CDI XML timeout, no datagrams in buffer | Capture with larger ring buffer or JMRI trace |
| CDI XML timeout, request sent, no reply | Test same node via TCP; check adapter firmware |
| Config read timeout (CDI XML succeeded) | Node responds to CDI reads but not config reads โ possible address-space issue |
| Serial works for SNIP but not CDI/config | Possible multi-frame datagram issue at adapter level |
| Everything works | No issue โ inform user the session was healthy |