| Stuck comb / zero output after release | Stiction, broken anchor, incomplete etch | SEM; gentle mechanical tap protocol; release yield map |
| Intermittent output | Particulate in cavity, loose wire bond, cracked beam | SEM; acoustic emission; bond shear test |
| Scale factor drift over days | Die attach creep, lid stress, moisture, outgassing | Hermeticity test; store in dry chamber; compare bare vs packaged |
| Scale factor tempco out of spec | Diaphragm stress, ASIC reference, mismatch in quad | Split mechanical vs electrical; multi-temp ASIC-only test |
| Excess noise density | ASIC PGA/flicker noise, supply ripple, insufficient settling | Open-loop spectrum; LDO audit; lengthen averaging at same (\tau) |
| Bias instability poor | Vacuum leak (Q change), thermoelastic noise, vibration on bench | Allan deviation vs (\tau); LDV on bench isolation |
| Gyro g-sensitivity high | Proof mass imbalance, incomplete mode match, quadrature | Rate table + linear acceleration sweep; trim limits |
| Quadrature error | Fabrication asymmetry, electrode offset | Factory trim; FEM sensitivity to mask misalignment |
| Pressure nonlinearity | Diaphragm buckling, cavity volume, port clog | Optical deflection vs output; media verification |
| Pressure hysteresis | Diaphragm plastic deformation, gel creep, particle on seat | Cycle pressure; SEM port |
| RF switch stuck closed | Welded contact, stiction, insufficient restore spring | Lift-off test; contact resistance history vs cycles |
| RF switch insertion loss high | Contact resistance, series cap, substrate coupling | S-parameter vs actuation voltage |
| Resonator Q drops in package | Squeeze-film at ambient pressure, anchor loss | Vacuum vs encapsulated compare |
| Resonator freq tempco | Material stack, anchor design | Temperature chamber freq track |
| Microfluidic clog | Particulate, bubble, surface chemistry | Visual inspection; flow rate vs pressure drop |
| Cross-axis sensitivity fail | Mounting misalignment, die placement, incomplete cal |