| name | new-building |
| description | Create a complete building model from scratch — geometry, envelope, loads, HVAC, weather, and simulation. Use when user wants to "create a building", "build a model", or "start a new model". |
| disable-model-invocation | true |
Create a Complete Building Model
Three workflows, from simplest to most customizable:
Workflow A: One-Call (Recommended)
create_new_building does everything — geometry, loads, HVAC, weather, design days:
create_new_building(
building_type="SmallOffice",
total_bldg_floor_area=10000,
num_stories_above_grade=1,
weather_file="/inputs/<city>.epw",
template="90.1-2019")
Ready to simulate immediately.
Workflow B: Bar + Typical (More Control)
Step 1 — Bar geometry (creates spaces, zones, surfaces):
create_bar_building(
building_type="SmallOffice",
total_bldg_floor_area=10000,
num_stories_above_grade=1,
template="90.1-2019",
climate_zone="4A")
Step 2 — Weather + design days + climate zone (MUST come AFTER bar):
change_building_location(weather_file="/inputs/<city>.epw")
This sets the EPW, loads design days from the DDY file, and sets the ASHRAE climate zone.
The EPW must have companion .stat and .ddy files alongside it (same base filename).
Step 3 — Typical building (adds constructions, loads, HVAC, schedules):
create_typical_building(
climate_zone="ASHRAE 169-2013-4A",
building_type="SmallOffice")
Workflow C: FloorspaceJS Custom Geometry
For buildings with custom floor plans drawn in FloorspaceJS editor
(https://nrel.github.io/floorspace.js/):
Step 1 — Import geometry:
import_floorspacejs(
floorplan_path="/inputs/floorplan.json",
building_type="SmallOffice")
Creates spaces, zones with thermostats, surfaces, and runs matching.
Step 2 — Weather + design days (same as Workflow B steps 2-3)
Step 3 — Typical building (same as Workflow B step 4)
Manual Workflow (Advanced)
For fully custom buildings not matching DOE prototypes:
load_osm_model an empty model, or start with create_bar_building for basic geometry
- Create/refine geometry with
create_space_from_floor_print + match_surfaces
- Add glazing with
set_window_to_wall_ratio
- Create materials/constructions/loads manually
- Add HVAC with
add_baseline_system
- Set weather with
change_building_location
- Check with
validate_model, then simulate
Simulation
After any workflow:
save_osm_model(save_path="/runs/<name>.osm")
run_simulation(osm_path="/runs/<name>.osm", epw_path="/inputs/<city>.epw")
get_run_status(run_id=<id>)
extract_summary_metrics(run_id=<id>)
Information to Gather
Ask the user for:
- Building type: SmallOffice, MediumOffice, LargeOffice, RetailStandalone,
Warehouse, PrimarySchool, Hospital, etc.
- Size: floor area in ft2, number of stories
- Location: city or climate zone (for weather file + ASHRAE climate zone)
- Custom geometry? If yes, ask for FloorspaceJS JSON file path
Climate Zone Format
For create_typical_building, use full format: "ASHRAE 169-2013-4A"