| name | visual-excellence |
| description | Drive a KiCad schematic to a professional, cosmetically clean state through a score → fix → render → verify loop using KiCad MCP Pro cosmetic tools. |
Visual Excellence Skill
Use this skill when an AI agent is asked to make a KiCad schematic look
professional — clean, readable, and conventionally drawn — not just electrically
correct. It closes the loop between measuring cosmetic quality, applying safe
fixes, and visually confirming the result.
This skill is specific to oaslananka/kicad-mcp-pro and should be kept
synchronized with docs/tools-reference.generated.md.
When to use
- Post-capture cleanup before layout or review
- Preparing a schematic for a datasheet, report, or customer hand-off
- Whenever a sheet "works but looks rushed": off-grid parts, diagonal wires,
colliding labels, sideways power symbols, inconsistent fonts
Do not use this skill to claim electrical correctness. Cosmetic fixes never
substitute for ERC, connectivity review, or human engineering approval. Run
sch_visual_qa / run_erc separately for correctness.
The invariant you can rely on
Every cosmetic fixer treats electrical connectivity as a hard invariant. It
computes a coordinate-independent connectivity signature before and after the
change; a fixer that would alter any net is refused on apply and never writes.
So you can apply fixes without fear of silently breaking a net — but always
confirm with the render and the visual diff, and finish with an ERC pass.
Required context
- Active project path and the schematic file(s)
- The target cosmetic score (default: 80/100)
- Whether you are allowed to modify the schematic (this skill mutates on
apply=true; it needs write operating mode)
Primary MCP tools
Measure
sch_cosmetic_score — 0–100 score with a per-category penalty breakdown and
the worst_category to fix first (grid, wiring, typography,
orientation, layout_balance, readability, documentation)
sch_visual_qa — readability findings (overlaps, off-sheet, dense fanout)
Fix (dry-run by default; pass apply=true to commit)
sch_align_to_grid — snap off-grid symbols, labels, wires, junctions
sch_straighten_wires — flatten almost-orthogonal wire segments
sch_resolve_label_overlaps — flip label justify so text stops colliding
sch_normalize_power_orientation — upright sideways power/ground symbols
sch_normalize_text_sizes — normalise outlier fonts onto the dominant size
See and verify
sch_render_png — render the sheet so you can visually evaluate it
sch_render_visual_diff — the exact before/after pixel delta of your last
mutation, plus the list of changed objects
run_erc — the electrical safety net after cosmetic edits
The loop
Run this loop per sheet until the score meets the target or no fixer applies:
- Measure. Call
sch_cosmetic_score. If cosmetic_score ≥ target, stop —
the sheet is clean. Otherwise read worst_category.
- Plan (dry run). Call the fixer matching
worst_category with the default
apply=false. Read connectivity_preserved and the changes list.
grid → sch_align_to_grid
wiring → sch_straighten_wires
readability (label overlaps) → sch_resolve_label_overlaps
orientation → sch_normalize_power_orientation
typography → sch_normalize_text_sizes
- Decide. If
connectivity_preserved is false, do not apply — the fix
would change a net. Report it and hand back to the human (or fix the
underlying wiring first). If true, continue.
- Apply. Call the same fixer with
apply=true. A refused status means the
invariant caught a connectivity change at commit time — treat it as step 3.
- See. Call
sch_render_png and evaluate the image against the rubric
below. Call sch_render_visual_diff and confirm the red delta covers only the
objects you intended to move.
- Re-measure. Call
sch_cosmetic_score again. Confirm the score rose and no
new category regressed. Return to step 1.
- Guard. After the loop, run
run_erc to confirm the cosmetic pass left the
design electrically intact.
Stop after a full pass where every applicable fixer reports no_change, even if
the score is still below target — the remaining gap needs human layout judgment,
not an automated fixer. Report what is left and why.
Rubric — what "professional" looks like
Compare the sheet you render against these two reference renders (both are the
same three-resistor circuit):
reference/professional.png — clean: parts aligned on a row, one horizontal
wire, and readable IN / MID / OUT labels.
reference/rushed.png — the same circuit drawn badly: the net labels collide
into an unreadable blob, the wire runs diagonally, and the parts sit off-grid
at uneven heights.
The rushed sheet is still electrically identical — this is exactly the class of
defect that ERC passes and cosmetic review must catch. When you evaluate a
sch_render_png, check for:
- Grid — parts and wires sit on a regular grid; nothing looks hand-nudged.
- Orthogonal wiring — wires run horizontally/vertically; no diagonals.
- Legible labels — net labels and reference designators do not overlap and
read cleanly against nearby text.
- Conventional symbols — power up, ground down, no sideways power symbols.
- Consistent typography — one dominant font size across the sheet.
- Balanced composition — content spreads across the sheet rather than
crowding one corner.
- Complete title block — title, revision, date, and company are filled in.
Judge the rendered image, not just the score: the score is a fast proxy, but the
render is the ground truth for readability.
Guardrails
- Cosmetic ≠ correct. Never sign off electrical behavior from this skill.
- Prefer dry runs first; only apply once
connectivity_preserved is true.
- If a fixer is refused, the underlying net topology needs a human — surface it,
do not force it.
- End with