| name | heat-sink-design |
| description | Heat sink design — fin geometry (rectangular/pin/corrugated), convection coefficient, thermal resistance network, forced/natural convection, pressure drop, material selection (Al/Cu), heat pipe integration, TIM selection, JEDEC standards, electronics cooling. |
| metadata | {"priority":7,"promptSignals":{"phrases":["heat sink design","fin heat sink","thermal resistance heat sink","electronics cooling","heat sink natural convection","forced convection heat sink"],"minScore":3}} |
Heat Sink Design — Complete Skill
Thermal Resistance Network
Junction-to-ambient thermal resistance:
R_ja = R_jc + R_cs + R_sa [°C/W; R_jc = junction-to-case; R_cs = case-to-sink; R_sa = sink-to-ambient]
Junction temperature:
T_j = T_ambient + Q × R_ja [°C; Q = power dissipated [W]]
Maximum junction temperature: set by device spec (e.g., T_j_max = 125°C for silicon; 150°C for SiC)
Derating: operate at T_j ≤ 0.8 × T_j_max (reduces failure rate)
Thermal interface material (TIM) resistance R_cs:
R_cs = t_TIM / (k_TIM × A_contact) [°C/W; t_TIM = bond line thickness; k_TIM = TIM conductivity; A = contact area]
Bond line thickness (BLT): 50–150 μm under clamping pressure
TIM options:
- Thermal grease (Dowsil TC-5026): k = 2–3 W/(m·K); BLT = 50–100 μm; reusable
- Phase change material: k = 3–6 W/(m·K); BLT = 75–125 μm; solid at room T, liquid at operating T
- Indium foil: k = 81 W/(m·K); BLT = 125–250 μm; very low resistance; expensive
- Thermal pad (Bergquist GP3000): k = 3 W/(m·K); BLT = 0.5–2 mm; easy assembly; higher resistance
R_cs typical values:
Thermal grease: R_cs = 0.01–0.05 °C/W (25 × 25 mm package)
Thermal pad: R_cs = 0.05–0.2 °C/W
Fin Geometry
Rectangular (Plate) Fins
Fin efficiency:
η_fin = tanh(mH) / (mH) [dimensionless; H = fin height; m = √(h_conv × P / (k_fin × A_c))]
P = fin perimeter; A_c = fin cross-section area; h_conv = convection coefficient; k_fin = fin material conductivity
For thin rectangular fin:
m = √(2h_conv / (k_fin × t)) [t = fin thickness]
η_fin decreases with increasing H and decreasing k_fin
Overall surface efficiency:
η_o = 1 - (N_fins × A_fin × (1 - η_fin)) / A_total [N_fins = number of fins; A_total = base + all fin areas]
Total thermal resistance:
R_sa = 1 / (η_o × h_conv × A_total) [°C/W]
Key dimensions:
Fin pitch S: distance between fins; S = 2–5 mm (forced convection); S = 8–15 mm (natural convection)
Fin height H: 15–50 mm typical; limited by pressure drop and manufacturing
Fin thickness t: 0.5–2 mm (aluminum); structural and manufacturing limit
Pin Fins
Cylindrical pin fin array:
h_conv per pin: depends on staggered vs. inline arrangement; Nu_D = C × Re_D^m × Pr^(1/3) (correlation)
Higher h_conv per pin area but lower total area vs. plate fins (for same volume)
Advantage: isotropic flow direction; good for omnidirectional air flow (natural convection)
Pin diameter: 1–4 mm; height: 10–30 mm
Corrugated (Folded) Fins
High surface area density: surface area density > 2,000 m²/m³ (plate fins: 200–800 m²/m³)
Used in: aircraft electronics, automotive intercoolers, high-performance CPUs
Very thin fins (0.1–0.4 mm); manufacturing by stamping + brazing
Low flow resistance: many flow channels with short hydraulic diameter
Convection Coefficient Calculation
Forced Convection (Internal Channel Flow)
Channel Nusselt number (laminar flow, Re < 2,300):
Nu = 3.66 (uniform temperature) or Nu = 4.36 (uniform heat flux) — parallel plate
For developing flow (short channels):
Nu = 7.54 + 0.03 × (D_h / L × Re × Pr) / (1 + 0.016 × (D_h / L × Re × Pr)^(2/3)) [Gnielinski; more accurate]
Turbulent (Re > 10,000):
Nu = 0.023 × Re^0.8 × Pr^(0.4 for heating; 0.3 for cooling) [Dittus-Boelter]
Or: Nu = (f/8 × (Re - 1000) × Pr) / (1 + 12.7 × √(f/8) × (Pr^(2/3) - 1)) [Gnielinski; more accurate]
Heat transfer coefficient:
h_conv = Nu × k_fluid / D_h [W/(m²·K); D_h = hydraulic diameter = 4A_c/P_wetted]
Air properties at 50°C: k = 0.0285 W/(m·K); μ = 1.96×10⁻⁵ Pa·s; Pr = 0.71; ρ = 1.09 kg/m³
Natural Convection
Vertical plate (Churchill-Chu correlation):
Nu_L = {0.825 + 0.387 × Ra_L^(1/6) / [1 + (0.492/Pr)^(9/16)]^(8/27)}²
Ra_L = g × β × ΔT × L³ / (ν × α) [β = 1/T_film for ideal gas; L = plate height; ν = kinematic viscosity; α = thermal diffusivity]
Simplified formula for air at 50°C ΔT:
h_conv_natural ≈ 1.42 × (ΔT/L)^0.25 [W/(m²·K); ΔT = surface-ambient [°C]; L = fin height [m]]
Typical: h ≈ 5–10 W/(m²·K) for natural convection (much lower than forced: 50–500 W/(m²·K))
Pressure Drop in Heat Sink
Pressure drop through fin channels:
ΔP = f × (L / D_h) × (ρ × v²/2) + K_entrance × (ρ × v²/2) + K_exit × (ρ × v²/2)
K_entrance ≈ 0.5 (sudden contraction); K_exit ≈ 1.0 (sudden expansion)
f × Re = 96 (parallel plates, laminar); f × Re = 56 (square channels)
Fan selection:
Operating point: fan curve P = f(Q) intersects system resistance curve P = K × Q²
P_system = ΔP through heat sink + duct losses
Fan laws: Q ∝ N; P ∝ N²; W ∝ N³ (for similar fan at different speeds)
Material Selection
| Material | k [W/(m·K)] | ρ [kg/m³] | Cost |
|---|
| Aluminum 6063 | 200 | 2,700 | Low |
| Aluminum 6061 | 167 | 2,700 | Low |
| Copper | 385 | 8,900 | High (4× Al) |
| Graphite foam | 40–150 | 250 | Medium |
| Vapor chamber | 10,000–20,000 eff. | 2,000 | High |
Aluminum (Al 6063-T5): dominant for heat sinks; k = 200 W/(m·K); extruded; excellent cost/performance
Copper: 2× better k than Al; used where weight is less critical (automotive ECU, power electronics)
Vapor chamber: passive two-phase device; spreads heat over large area; effective k >> 1,000 W/(m·K); for spot heat sources
Heat Pipe Integration
Heat pipe principle: wick-assisted capillary pumping of evaporation-condensation cycle; k_eff = 10,000–100,000 W/(m·K) (much higher than any solid)
Diameter: 3–10 mm (sintered wick or axial groove); bending radius ≥ 3D
Maximum heat transport (capillary limit):
Q_max = A_w × k_eff × ΔT_max / L [simplified; actual depends on wick structure and fluid]
6 mm heat pipe, water fill, L = 150 mm: Q_max ≈ 30–80 W per pipe
Design: embed heat pipe in Al heat sink base → spreads heat from source over entire fin array; reduces spreading resistance
JEDEC Standards
JEDEC JESD51: standardized methods for junction-to-ambient thermal resistance measurement
- JESD51-2: natural convection conditions for θja measurement
- JESD51-6: forced convection conditions
θja (junction-to-ambient): single number; combines junction-to-case, case-to-board, board-to-ambient — not sufficient for system design
θjb (junction-to-board): better metric for surface-mounted components in PCB assemblies
Ψjt (junction-to-top): measures thermal gradient to top of package; used with external heat sink design
Design Optimization
For given Q and T_j constraint:
Required R_sa = (T_j - T_ambient) / Q - R_jc - R_cs
R_sa determines: fin area, fin count, fin height, air flow rate needed
Optimization trade-off:
More fins (smaller pitch): ↑ area → ↑ Q per ΔT; but ↑ pressure drop → ↓ flow rate → ↑ R_sa (counterproductive)
Optimal fin pitch: maximize Q / (η_o × h × A × ΔP) — complex optimization; use CFD or correlations
Standards
| Standard | Scope |
|---|
| JEDEC JESD51 | Thermal resistance measurement methodology |
| JEDEC JESD51-2 | Natural convection thermal measurement |
| JEDEC JESD51-6 | Forced convection thermal measurement |
| IPC-7093 | Design and assembly guidelines for SMT |
| MIL-HDBK-251 | Reliability derating for electronics (thermal) |
Output
Provide: power dissipation Q [W] and maximum T_j [°C], thermal budget allocation (R_jc + R_cs + R_sa + R_ambient = ΔT/Q), required R_sa [°C/W], fin geometry (type, number, height H [mm], thickness t [mm], pitch S [mm]), fin material and k [W/(m·K)], fin efficiency η_fin [%], overall surface efficiency η_o [%], convection coefficient h [W/(m²·K)] (forced or natural), air velocity [m/s] or flow rate [CFM/m³/h], pressure drop ΔP [Pa], total thermal resistance R_sa_actual [°C/W], T_j_predicted [°C] vs. T_j_max, and applicable standard (JEDEC JESD51-2/6, MIL-HDBK-251).