set-thermal-profile

Set the thermal escalation policy of an Intel host with tools/power-tuning/set_thermal_profile.sh — generate, validate, apply and verify a thermald thermal-conf.xml that stages a response on the CPU package sensor (Fan active < Processor passive < intel_powerclamp passive). Choose a ready-made profile (cool 55/70/80, warm 60/75/85, hot 70/90/95, thermal-max 95/100/104, in °C for Fan/Processor/powerclamp) or a Custom set of trip points, optionally add the CHRG cooling device, and make thermald the sole thermal authority. Also supports disabling thermald to revert to kernel default thermal control.

Datos de origen

Repositorio
open-edge-platform/edge-node-infrastructure-blueprint
Última actividad en el origen
30 de julio de 2026 a las 10:50
Idioma detectado de SKILL.md
inglés
Estrellas
1
Forks
9

Opciones de instalación

De forma predeterminada está seleccionado el prompt que primero revisa el origen. Puedes cambiar a un comando directo o descargar una copia local.

Revisa los archivos de origen

Lee SKILL.md y los archivos complementarios que muestra SkillsMP antes de decidir si quieres instalarlo.

Mostrando SKILL.md

SKILL.md
Instrucciones de origen · Vista previa de solo lectura
name
set-thermal-profile
description
Set the thermal escalation policy of an Intel host with tools/power-tuning/set_thermal_profile.sh — generate, validate, apply and verify a thermald thermal-conf.xml that stages a response on the CPU package sensor (Fan active < Processor passive < intel_powerclamp passive). Choose a ready-made profile (cool 55/70/80, warm 60/75/85, hot 70/90/95, thermal-max 95/100/104, in °C for Fan/Processor/powerclamp) or a Custom set of trip points, optionally add the CHRG cooling device, and make thermald the sole thermal authority. Also supports disabling thermald to revert to kernel default thermal control.
## Purpose `set_thermal_profile.sh` generates, applies and verifies a **thermald** thermal profile. It builds a `/etc/thermald/thermal-conf.xml` with a staged escalation on the CPU package sensor (`x86_pkg_temp`): ``` Fan (active) < Processor (passive) < intel_powerclamp (passive) fans on early cap CPU frequency inject idle cycles (hard limit) ``` then makes thermald the sole thermal authority (systemd drop-in with `--ignore-default-control` and **without** `--adaptive`, so firmware DPTF/GDDV adaptive tables do not override the trip points) and verifies the result. This skill only automates the reference script. The thermal profile pairs with the power envelope from `set-power-profile`: the power cap bounds how much heat is produced, while this thermal profile governs how the platform reacts as package temperature rises. ## Terminology Acronyms and terms used throughout this skill. | Term | Meaning | |---|---| | thermald | The Linux thermal daemon that consumes the generated `thermal-conf.xml` and drives the cooling devices. | | trip point | A temperature threshold at which a cooling action is engaged. | | active trip | A cooling response that does **not** cost performance — here, turning fans on. | | passive trip | A cooling response that **reduces performance** to shed heat — frequency capping or idle injection. | | x86_pkg_temp | The CPU package temperature sensor the profile escalates on. | | Fan | The active cooling device (fans) engaged at the first (lowest) trip. | | Processor | The passive cooling device that caps CPU frequency at the middle trip. | | intel_powerclamp | The passive cooling device that injects idle cycles (hard limit) at the top trip. | | CHRG | The battery-charge cooling device; optionally added to the top trip when present (`--charge`). | | Tjmax | The silicon's maximum junction temperature (~110 °C); the top trip must stay below it. | | DPTF / GDDV | Firmware adaptive thermal framework/tables that would override the config unless thermald runs without `--adaptive`. | | cooling device | A `/sys/class/thermal/cooling_device*` the kernel exposes (Fan, Processor, intel_powerclamp, CHRG, …). | | systemd drop-in | An `override.conf` that re-declares thermald's `ExecStart` so our config is authoritative. | | dry_run | Preview mode: print the plan and generated XML without writing anything or touching the daemon. | ## Profile Table Trip points are in Celsius, ordered Fan (active) < Processor (passive) < powerclamp (passive). | Profile | Fan | Processor | powerclamp | Notes | |---|---|---|---|---| | cool | 55 | 70 | 80 | Aggressive cooling; fans on early, runs coolest/quietest-at-cost-of-perf | | warm *(default)* | 60 | 75 | 85 | Balanced | | hot | 70 | 90 | 95 | Lets the platform run warmer before intervening | | thermal-max | 95 | 100 | 104 | Pushes to Tjmax headroom; **runs hot** | | custom | `--fan` | `--proc` | `--clamp` | Supply your own trip points | ## Trigger Phrases - set thermal profile - apply thermal profile - set thermal profile to cool / warm / hot / thermal-max - configure thermald / set thermald trip points - set cpu thermal trip points - generate thermal-conf.xml - make thermald the sole thermal authority - set custom thermal trips (fan/proc/clamp) - add CHRG cooling device to thermal profile - disable thermald / revert to kernel default thermal control - run hot / run cool thermally ## Required Inputs - enib_home: absolute path to this repository root (default: current workspace root). On a host provisioned with Infrastructure Blueprint, the developer source tree lives at `/opt/edge/developer`, so `enib_home` is `/opt/edge/developer` on the target system. - profile: one of `cool`, `warm`, `hot`, `thermal-max`, or `custom`. Optional; defaults to `warm` when not supplied — the skill does not prompt for it. Passed via `--profile/-p` (a bare positional word is rejected by the script). - fan_c: Fan (active) trip in Celsius. **Only for `custom`** (required there); ignored for named profiles unless explicitly overriding. - proc_c: Processor (passive) trip in Celsius. **Only for `custom`** (required there). - clamp_c: powerclamp (passive) trip in Celsius. **Only for `custom`** (required there). - charge: `true` | `false` (default: `false`). When `true`, add the CHRG (battery charge) cooling device to the top trip **if present** on the platform (`--charge`). - output_file: optional path. When set, write the generated XML there and make **no** daemon changes (`-o FILE`). Implies no install. - disable: `true` | `false` (default: `false`). When `true`, stop thermald and disable it at boot (`--disable`), reverting to kernel default thermal control. Ignores profile options; leaves config/override files untouched. - dry_run: `true` | `false` (default: `false`). When `true`, only the plan and generated XML are shown; nothing is written and no service is touched (`--dry-run`). - auto_confirm: `true` | `false` (default: `false`). When `true`, skip the confirmation gate. ## Preconditions Run silently without user prompts: - [ ] Skill file exists and is readable: - `test -f <enib_home>/skills/set-thermal-profile/SKILL.md` - [ ] The thermal script exists and is executable: - `test -x <enib_home>/tools/power-tuning/set_thermal_profile.sh` - [ ] `thermald` is installed (needed to validate and run the config; not needed for `dry_run` or `output_file` mode): - `test -x /usr/sbin/thermald` - if missing, stop and instruct: install it (Ubuntu: `sudo apt-get install -y thermald`), then re-trigger. - [ ] Host is x86_64 with an Intel CPU (sanity check; non-fatal warning if not): - `uname -m` and `grep -m1 -o 'GenuineIntel' /proc/cpuinfo` - [ ] Detect the cooling devices present (informational; the script omits steps for absent devices and refuses to write an empty zone): - `grep -s . /sys/class/thermal/cooling_device*/type` — note whether `Fan`, `Processor`, `intel_powerclamp` (and `CHRG` when `charge=true`) are present. - [ ] **Sudo probe (MANDATORY before any apply / `--disable`)** — the script mutates `/etc/thermald/` and restarts the service and does **not** self-elevate: run `sudo -n true`. If exit is non-zero, do NOT apply; stop and instruct the user to run `sudo -v` in their terminal (or add a scoped `NOPASSWD` entry for the absolute path to `set_thermal_profile.sh` in `/etc/sudoers.d/`), then re-trigger. If `sudo -v` was already run but `sudo -n true` still fails (tty_tickets), make timestamps global: `echo 'Defaults timestamp_type=global' | sudo tee /etc/sudoers.d/agent-timestamp && sudo chmod 0440 /etc/sudoers.d/agent-timestamp && sudo visudo -c`. Never collect a password via prompts, env vars, scripts, or logs. `dry_run=true` and `output_file` mode need no sudo (read-only / no daemon changes). See [AGENTS.md](../../AGENTS.md#sudo-handling-must-follow-for-all-skills-that-invoke-sudo). Prompt only for missing required inputs: - [ ] Do not prompt when `profile` is omitted — default to `warm`. - [ ] Only for `profile=custom`: if any of `fan_c`, `proc_c`, `clamp_c` is missing, ask for the three trip points (the script requires all three for `custom`). Input validation (fail closed before running the script): - [ ] `profile` matches one of `cool|warm|hot|thermal-max|custom`. Otherwise stop and list the valid profiles. - [ ] For `custom` (or when overriding a named profile): `fan_c`, `proc_c`, `clamp_c` are positive integers satisfying `fan_c < proc_c < clamp_c` and `clamp_c < 105` (must stay below Tjmax). Warn if `fan_c < 30` (near idle; CPU may stay throttled). - [ ] `output_file`'s parent directory exists and is writable (when supplied). - [ ] `disable`, `charge`, `dry_run`, `auto_confirm` are booleans. `disable=true` is mutually exclusive with profile/custom trip options (the script ignores them under `--disable`). ## Steps **Terminal command rules (MUST follow for every command in this skill):** - Always invoke scripts by **absolute path** — never prefix with `cd`. - Never combine `cd` with any output redirection (`>`, `>>`, `2>`, `2>&1`, `| tee`) in the same compound command — this triggers the VS Code approval dialog. Run them as separate commands if both are needed. - Never use `$(...)` command substitution in terminal commands — VS Code blocks them with an approval dialog. The script handles all internal computation itself. 1. Resolve the plan (no writes yet). Build the argument list: - Base: `<enib_home>/tools/power-tuning/set_thermal_profile.sh --profile <profile>` - For `custom`, append `--fan <fan_c> --proc <proc_c> --clamp <clamp_c>`. - Append `--charge` only when `charge=true`. - For `output_file` mode, append `-o <output_file>` (no daemon changes). - For `disable=true`, use `--disable` instead of the profile/trip options. 2. **Always execute a dry run first** (read-only, no sudo, no writes) unless the invocation is `output_file`-only: - Run the resolved command with `--dry-run` (add `--disable` when disabling) and capture the summary and the generated XML verbatim. - This runs unconditionally on every apply invocation, including when `auto_confirm=true`. 3. **Render the Planned Changes as a table** built from the dry-run output: profile, resolved Fan/Processor/powerclamp trips, CHRG yes/no, which cooling devices are present vs will be wired in, config target (`/etc/thermald/thermal-conf.xml` or `output_file`), and the effective `ExecStart`. Show it before any write. 4. **Confirmation gate** — pause before any write: - If `dry_run=true`: stop here and record `CONFIRMATION=dry_run_only`. Do not apply. - Else if `output_file` is set: this only writes the XML (no daemon changes) — treat as low-risk; still show the plan, then proceed (respect `auto_confirm`; otherwise confirm). - Else if `auto_confirm=true`: log `AUTO_CONFIRM=true` and continue. - Else: present the tabulated Planned Changes and ask "Apply the <profile> thermal profile (Fan <F>°C / Processor <P>°C / powerclamp <C>°C) and make thermald the sole thermal authority on this host? (yes/no)" (or, for disable: "Stop and disable thermald, reverting to kernel default thermal control? (yes/no)"). On anything other than `yes`/`y` (case-insensitive), stop and record `CONFIRMATION=declined`. 5. Apply (only after confirmation). The script does **not** self-elevate, so prefix with `sudo` for apply / `--disable` (not for `--dry-run` or `-o`): - `sudo <enib_home>/tools/power-tuning/set_thermal_profile.sh --profile <profile> [custom/charge flags]` - The script validates the generated XML in thermald test-mode, backs up any existing config/override, installs, `daemon-reload`s, restarts thermald, and verifies the running daemon. Capture stdout/stderr verbatim and record the exit code. 6. Capture the effective state for the report (read-only): - `systemctl is-active thermald` - the effective `ExecStart` and the confirmation line the script prints (sole thermal authority ✔ / warning). - current package temperature (the script prints it at the end). ## Validation Validation section is criteria-only. Do not render the pass/fail results table here. - Preconditions passed (script executable; `thermald` present for apply; sudo probe = 0 when an apply/disable is intended). - `profile` validated; for `custom`, trip points validated for ordering (`fan < proc < clamp`), `clamp < 105`, and positive integers. - A dry run was executed first on every apply invocation, and the Planned Changes table was rendered from its output before the confirmation gate. - Confirmation gate outcome recorded as one of: `confirmed`, `auto_confirm`, `declined`, `dry_run_only`. - Apply phase only executed when the outcome is `confirmed` or `auto_confirm`. - When applied, the script exited with code `0`, thermald is `active`, and the effective `ExecStart` contains `--ignore-default-control` and **not** `--adaptive` (sole thermal authority). - When `output_file` mode, the XML was written to the given path and no daemon changes were made. - When `disable=true`, thermald is stopped and disabled and the script reported kernel default thermal control now applies. ## Rollback - Re-run with a different `profile` to change the trip points (the script backs up the previous config to `${CONF_FILE}.bak` and the override to `${OVERRIDE_FILE}.bak`). - Restore the previous config manually: `sudo cp /etc/thermald/thermal-conf.xml.bak /etc/thermald/thermal-conf.xml && sudo systemctl restart thermald`. - To fully revert to kernel default thermal control, run the skill with `disable=true` (`--disable`): it stops thermald and disables it at boot, leaving config/override files untouched. Re-enable later with `sudo systemctl enable --now thermald`. - The config and systemd override persist across reboot (unlike the runtime-only RAPL power cap from `set-power-profile`). ## Safety Rules - Never collect a sudo password and never prompt for sudo approval during skill execution; passwordless sudo is expected to be pre-configured (scoped `NOPASSWD` for the absolute path to `set_thermal_profile.sh`). Never collect a password via prompts, env vars, scripts, or logs. - **Never combine `cd` with output redirection** in the same compound terminal command — VS Code blocks such commands. Use absolute paths; split commands if redirection is needed. - **Never use `$(...)` command substitution in terminal commands** — VS Code blocks them. Delegate all computation to the script. - Warn before applying `thermal-max` (runs near Tjmax) or a high `custom` `clamp_c` on thermally constrained (e.g. fanless) enclosures — the platform will run hot and may thermally throttle only very late. - On a fanless enclosure the `Fan` active step is omitted (no such device); note that the platform then relies solely on the passive steps (frequency cap + idle injection). - The script restarts `thermald` to load the new profile; note the brief management gap. If the script aborts mid-run it restores the previously running daemon. - Do not modify anything outside `tools/power-tuning/`, `/etc/thermald/`, and the thermald systemd drop-in the script manages. ## Expected Result Summary Render the report as the following tables. ### Run Metadata | Field | Value | |---|---| | Preconditions | PASS/FAIL | | Host | `<uname -m>` + CPU model name | | Mode | `apply` / `output-file` / `disable` | | Profile | `<profile>` (n/a when disabling) | | Fan trip | `<F>°C (active)` | | Processor trip | `<P>°C (passive)` | | powerclamp trip | `<C>°C (passive)` | | CHRG device | `yes` / `no` | | Config target | `/etc/thermald/thermal-conf.xml` or `<output_file>` | | Dry run only | `true` / `false` | | Confirmation | `confirmed` / `auto_confirm` / `declined` / `dry_run_only` | ### Planned Changes | Item | Value | Notes | |---|---|---| | STEP 1 (active) | Fan @ `<F>`°C | omitted if no Fan device | | STEP 2 (passive) | Processor @ `<P>`°C | frequency cap; omitted if no Processor device | | STEP 3 (passive) | intel_powerclamp @ `<C>`°C | idle injection; omitted if absent | | Thermal authority | `--ignore-default-control`, no `--adaptive` | thermald is sole authority | ### Effective State (pre → post) (omit when the outcome is `declined` or `dry_run_only`) | Field | Before | After | |---|---|---|