| description | Make the environmental cost of AI usage visible โ floor estimates built from published per-prompt figures, rendered as lightbulb time (๐ก), with an optional weekly energy budget that informs but never blocks. Use when the user asks "how much energy did this session cost", "what's the environmental cost", "show the energy footer", "set an energy budget", "energy report", or enables environmental awareness in the limits-setup interview. |
Limits: energy
Every prompt burns real electricity and water in a real data center. This
skill makes that cost visible โ as an honest floor estimate, not a guilt
trip and not a fake precision instrument.
Pairs with limits-setup, which writes the config this skill reads.
The honesty contract (binding on you, the agent)
-
Inform by default; gate only by explicit opt-in. Energy numbers
inform. The one exception is a budget the user set with
ENERGY_BUDGET_MODE=restrict, chosen eyes-open in the interview โ
then the gate is theirs, and the honesty burden doubles: they are
being governed by a floor estimate on purpose, and every refusal says
so.
-
Cited figures only, provenance inline. The two published anchors,
with what they cover:
- ~0.24 Wh โ Google's published median for a Gemini Apps text
prompt (2025). Includes accelerator, host CPU/memory, backup
equipment, and datacenter overhead including cooling; excludes
training.
- ~0.34 Wh โ OpenAI's figure for an "average" ChatGPT query
(2025, from Sam Altman's blog). Not peer-reviewed; "average query"
is undefined.
Both are vendor self-reported. Say so when asked.
-
Never invent a conversion. There is no published per-token energy
figure โ do not create one. Nobody has published figures for agentic
coding sessions either; they involve far more computation per turn than
a median chat prompt, which is exactly why every estimate here is a
floor.
-
No shame mechanics. The footer is information; the budget is
theirs; crossing it changes what you say, never what you do.
Estimating: count turns, multiply, call it a floor
A "turn" is one model call โ each response, including each tool-use step in
an agentic session, is one. Turns are countable; per-turn cost is not
knowable, so:
estimated floor = (turns you can count) ร 0.24 Wh (the conservative
anchor)
The footer shows only the result (see Rendering); the method stays one
question away โ when they ask "how was this measured", give the math, the
turn count, and both anchors with provenance. When you cannot count turns
on a surface, estimate the count conservatively and say you did. Never
present a result without its floor marker: a trailing + on the number
(36+ Wh), which reads naturally and stays true โ the real cost is
higher, never lower.
Rendering: keep it light
One terse line, emoji that scale with the magnitude, no method talk.
End-of-session footer (only when ENERGY_FOOTER=yes in
~/.config/ai-limits/config, or on request; skip it in automated
sessions):
๐ก๐ก๐ก๐ก๐ก๐ก 6+ Wh this session ยท lights on for ~40 min
At bigger totals, switch units so the emoji stay meaningful:
๐ฑ๐ฑ๐ฑ 51+ Wh this week ยท 3 full phone charges ยท lights on for ~5 hours
Rules:
- The number: counted turns ร 0.24 Wh, rounded, with a trailing
+
carrying the floor.
- ๐ก one per Wh, capped at ten. ๐ฑ one per full phone charge
(~15 Wh), capped at ten โ use phones once bulbs stop being legible.
- Felt equivalents: lights-on time = Wh รท 10 W LED; a phone charge
โ 15 Wh. Month- and year-scale equivalences (โ๏ธ flights and beyond)
need cited energy-to-carbon conversions โ that's the energy tracker's
job, not this footer's.
- Nothing else on the line. Method and provenance are answers, not
furniture.
Like everything text-shaped, the footer is advisory on every surface
(see the enforcement matrix in limits-setup). It works by being followed.
The weekly budget (optional, three modes)
The interview offers four paths; config records them:
| Choice | Config | Behavior |
|---|
| No thanks | ENERGY_FOOTER=no | Energy never comes up |
| Inform only | footer on, no budget | The footer, nothing else |
| Budget + warn | ENERGY_BUDGET_MODE=warn | Crossing the budget gets exactly this, once per week, and nothing more: "๐ FYI, you've exceeded your weekly energy budget of Wh." |
| Budget + restrict | ENERGY_BUDGET_MODE=restrict | The energy-gate.sh hook refuses further prompts once the week's floor crosses the budget โ terse, identical, overridable through a deliberate typed act (don't volunteer the command; tell them if they ask) |
The budget week is fixed: it starts Monday at the day boundary (default
4AM) and resets the following Monday โ a reset you can name, not a rolling
window that follows you around.
Always, whenever the footer is on โ budget or not:
- Where a filesystem exists, append one line per session to
~/.config/ai-limits/state/energy-ledger.log:
2026-08-27 wh=2+ turns=8 <one-word context> โ keep this format
stable and parseable; it is the data source for the budget math, the
weekly report, and the first-week baseline a person sets their budget
against.
- Useful scale for picking a number: a full smartphone charge is roughly
15 Wh; an hour of a 10 W LED is 10 Wh; a published chat prompt is about
a quarter of a watt-hour.
- Restrict mode's honest label: it is the softest of the kit's three
gates. Quiet hours read the clock; the session gate reads hook-written
state; this gate reads a ledger the AI itself writes at session ends โ
real enforcement fed by best-effort data. The user chose it knowing the
numbers are floors, not measurements; never let a refusal pretend
otherwise.
The baseline review
When the config has ENERGY_FOOTER=yes and no ENERGY_BUDGET_WH_WEEK,
and the ledger holds a week of data: the next limits/energy report opens
with the baseline โ the week's floor total, rendered honestly โ and asks
them to set their budget number against it (and the enforcement mode, if
5b recorded "not sure"). This is the one moment the kit proactively asks;
it isn't a nag โ it's the appointment their own 5a answer scheduled. If
they defer, defer; ask again only at the next report they request.
Weekly report
When asked ("energy report", or as part of a limits report): sum the
ledger's ranges, render the lightbulb row, compare to the budget if one is
set, and state what the number is: a floor estimate of one slice of the
true cost โ it excludes training, embodied hardware, idle capacity, and
anything the providers don't publish. Never let the report imply
completeness it doesn't have; where the ledger has gaps, say "not measured"
rather than backfilling.