Skip to main content

gating-deid-leakage

Add a CI gate that fails the build when an OpenMed de-identification model's recall on a held-out PHI set drops below threshold or any critical identifier leaks. Use when the user wants a pytest test or CLI step that exits nonzero on de-id regression, wants to wire OpenMed's leakage-first release gates into GitHub Actions / CI, needs a recall floor plus zero-leakage assertion against a synthetic held-out set, or wants to block merges that weaken de-identification. Trigger on "CI gate", "fail the build", "regression test", "de-id recall threshold", "block the merge", "exit nonzero", or "leakage check in CI" for OpenMed.

설치로 이동

소스 정보

저장소
maziyarpanahi/openmed
최근 소스 활동
2026년 7월 20일 09:27
감지된 SKILL.md 언어
영어
스타
5,421
포크
694

설치 방법

기본적으로 소스를 먼저 확인하는 Prompt가 선택됩니다. 직접 명령으로 전환하거나 로컬 사본을 다운로드할 수도 있습니다.

소스 파일 검토

설치 여부를 결정하기 전에 SKILL.md와 SkillsMP에 표시된 보조 파일을 읽어 보세요.

SKILL.md 표시 중

SKILL.md
소스 지침 · 읽기 전용 미리보기
name
gating-deid-leakage
description
Add a CI gate that fails the build when an OpenMed de-identification model's recall on a held-out PHI set drops below threshold or any critical identifier leaks. Use when the user wants a pytest test or CLI step that exits nonzero on de-id regression, wants to wire OpenMed's leakage-first release gates into GitHub Actions / CI, needs a recall floor plus zero-leakage assertion against a synthetic held-out set, or wants to block merges that weaken de-identification. Trigger on "CI gate", "fail the build", "regression test", "de-id recall threshold", "block the merge", "exit nonzero", or "leakage check in CI" for OpenMed.
license
Apache-2.0
metadata
{"project":"OpenMed","category":"evaluation-quality","pairs":"adjacent","version":"1.0"}
# Gating De-id Leakage in CI Logs, baselines, and models drift. The only durable defense is a gate that runs on every change and **fails closed** when de-identification regresses. This skill operationalizes OpenMed's leakage-first ethos into a CI check: recall must stay above the floor and **critical leakage must be exactly zero**, or the build goes red. ## When to use this skill - You want a pytest test or CLI step that exits nonzero on de-id regression. - You need to block PRs that drop PHI recall or introduce a leak. - You want OpenMed's release gates (`ReleaseGate`, G1a–G8) enforced in CI. - You maintain a synthetic held-out PHI set and want it checked automatically. For the full gate semantics see `evaluating-with-leakage-gates`; this skill is about *wiring it into CI so it fails the build*. ## Quick start — a pytest gate ```python # tests/eval/test_deid_leakage_gate.py import pytest from openmed.eval import run_suite, ReleaseGate, RELEASABLE RECALL_FLOOR = 0.99 # direct-identifier recall floor HELD_OUT = "eval/heldout/phi_synthetic.json" # SYNTHETIC, committed @pytest.fixture(scope="module") def gate_report(): report = run_suite( HELD_OUT, suite="golden", model_name="OpenMed/Privacy-PII-Detection", device="cpu", metadata={"family": "PII", "tier": "base", "policy": "hipaa_safe_harbor"}, ) return ReleaseGate(milestone="v1.6", policy="hipaa_safe_harbor").evaluate(report) def test_no_critical_leakage(gate_report): # Hard zero: one leaked SSN/credit-card is a breach, full stop. assert gate_report.critical_leakage_count == 0, "critical PHI leaked" def test_recall_floor(gate_report): low = { label: r for label, r in gate_report.per_label_recall.items() if r < RECALL_FLOOR } assert not low, f"recall below floor: {low}" def test_releasable(gate_report): # The structural decision: any failed gate -> QUARANTINED -> red build. failed = [c.gate for c in gate_report.gate_results if not c.passed] assert gate_report.decision == RELEASABLE, f"quarantined; failed gates: {failed}" ``` `pytest` exits nonzero on any failure, so CI turns red automatically. ## Quick start — a CLI gate The harness ships a `main()` that **fails closed** (exit 1 on quarantine): ```bash # Produce a candidate report, then gate it. Nonzero exit blocks the job. python -m openmed.eval.release_gates \ --candidate eval/out/candidate_report.json \ --baseline-store eval/baselines/last_green.json \ --milestone v1.6 --policy hipaa_safe_harbor \ --output release-gate-report.json ``` Exit codes: `0` RELEASABLE, `1` QUARANTINED, `2` evaluation error before a report. CI should treat `1` and `2` as failures. ## Wire it into GitHub Actions ```yaml # .github/workflows/deid-gate.yml name: de-id leakage gate on: [pull_request] jobs: gate: runs-on: ubuntu-latest steps: - uses: actions/checkout@v4 - uses: astral-sh/setup-uv@v5 - run: uv pip install --system -e ".[hf]" - name: Run de-id leakage gate run: uv run pytest tests/eval/test_deid_leakage_gate.py -q # The job fails (red) automatically if pytest exits nonzero. ``` ## Workflow 1. **Curate a synthetic held-out PHI set** and commit it (offsets + labels, no real patient text). Use `building-gold-corpus`. It must be disjoint from any calibration/training data. 2. **Pick the floor from policy.** Don't hardcode a magic number you invented — align to the gate's published floors (`G1A_V16_RECALL_FLOOR` etc. in `openmed.eval.release_gates`) and the active policy profile. 3. **Run the suite → gate the report** (pytest fixture above). 4. **Assert two invariants**: `critical_leakage_count == 0` and per-label recall ≥ floor. Optionally assert `decision == RELEASABLE` for the full G1a–G8 check. 5. **Make it required.** Mark the job a required status check so a red gate blocks merge — a passing-but-not-required gate protects nothing. 6. **On failure, the harness CLI can open/refresh a tracking issue** (`--issue-on-failure`) so the regression is visible, not silently retried. ## Hand-off to / from OpenMed - **From** `evaluating-with-leakage-gates`: this skill is the CI wrapper around the same `ReleaseGate.evaluate(...)` call — reuse its gate semantics. - **From** `building-gold-corpus`: supplies the synthetic held-out fixtures the gate runs against. - **To** `authoring-model-cards`: a green gate's `GateReport` is the evidence the model card cites under "evaluation". - **Pairs with** `enforcing-nophi-logging`: the gate proves the *model* doesn't leak; the logging guard proves your *runtime* doesn't leak. ## Edge cases & gotchas - **Fail closed, never open.** If the candidate report is missing or the eval errors, treat it as a failure. Don't `|| true` the step. - **A passing F1 is not a passing gate.** Recall floor + zero critical leakage are the load-bearing assertions; assert them explicitly even if you also check `decision`. - **Held-out must stay held-out.** If the gate set leaks into calibration or training, the gate measures memorization, not generalization. Keep splits disjoint (see `building-gold-corpus`). - **Pin the model and milestone.** Floors change per milestone (v1.6 vs v2.0); pin both so a "passing" gate doesn't silently weaken. - **No real PHI in CI artifacts or logs.** The gate report is offsets/hashes only; don't print fixture text in CI output. - **Baselines are inputs, not outputs of the gate.** Promote last-green baselines in a separate, reviewed step — never auto-write them from the gate job. ## Standards & references - HIPAA Safe Harbor de-identification standard (45 CFR 164.514): https://www.hhs.gov/hipaa/for-professionals/privacy/special-topics/de-identification/ - NIST SP 800-188, *De-Identification of Personal Information*: https://csrc.nist.gov/pubs/sp/800/188/final - GitHub Actions required status checks: https://docs.github.com/actions/using-workflows/required-status-checks - OpenMed eval source of truth: `openmed/eval/release_gates.py` (`main`, `ReleaseGate`), `openmed/eval/harness.py`.
GitHub에서 보기