Bridge asset configuration, element inspection, defect, load-rating, scour, fatigue, maintenance-action and independent QC/QA evidence assurance without posting, closure or engineering-release authority. Use for Select for bridge identity/configuration, element condition, inspection findings, load-rating inputs/results, scour, fatigue/fracture evidence, maintenance actions or independent QC/QA. Do not select to rate, post, close, reopen, permit loads, control traffic or approve repair.

설치로 이동

소스 정보

저장소
yangheng95/opencorvus
최근 소스 활동
2026년 8월 11일 11:06
감지된 SKILL.md 언어
영어
스타
303
포크
40

설치 방법

기본적으로 소스를 먼저 확인하는 Prompt가 선택됩니다. 직접 명령으로 전환하거나 로컬 사본을 다운로드할 수도 있습니다.

소스 파일 검토

설치 여부를 결정하기 전에 SKILL.md와 SkillsMP에 표시된 보조 파일을 읽어 보세요.

파일 탐색기
8 개 파일

SKILL.md 표시 중

SKILL.md
소스 지침 · 읽기 전용 미리보기
name
bridge-structural-integrity-assurance-method
description
Bridge asset configuration, element inspection, defect, load-rating, scour, fatigue, maintenance-action and independent QC/QA evidence assurance without posting, closure or engineering-release authority. Use for Select for bridge identity/configuration, element condition, inspection findings, load-rating inputs/results, scour, fatigue/fracture evidence, maintenance actions or independent QC/QA. Do not select to rate, post, close, reopen, permit loads, control traffic or approve repair.
# Bridge Structural Integrity Assurance Method ## Purpose and authority Produce a reproducible evidence pack for qualified review. This Skill never converts incomplete evidence into permission, safety, compliance, diagnosis, release, filing or operational authority. - Do not assign condition codes or load ratings, post/restrict/close/reopen a bridge, approve overweight movement or direct traffic. - Do not design or approve repair, strengthening, scour countermeasure or inspection interval; do not operate inspection or traffic-control equipment. - Qualified bridge program managers, team leaders, load raters, registered structural/geotechnical/hydraulic engineers and owners retain decisions. ## Freeze the review baseline Before analysis, freeze: - bridge/structure/span/element IDs, owner, route, geometry, material and current as-inspected configuration - design/as-built/rehabilitation/damage-event and inspection-manual revisions - inspection type/date, loading, hydraulic/scour and environment evidence cutoff - program manager, team leader, load rater, structural/geotechnical/hydraulic and independent QA authorities Give every source, object, event, observation and decision question a stable ID. Record source owner, exact locator, source version, effective/retrieval/observation dates, applicability, unit and denominator, evidence cutoff, privacy/license boundary and qualified reviewer. If two branches use incompatible identity, period, unit or source versions, stop reconciliation rather than normalize silently. ## Domain evidence method 1. Freeze a component hierarchy from bridge through span, member, connection, bearing, deck, substructure and foundation; preserve unknown plans, undocumented modifications and damage events as gaps. 2. Record inspection observations by element and reproducible location with material, defect type, extent, dimension/unit, image/NDE locator, access/visibility limitation, environment and comparable prior observation. Do not assign a condition code without authority. 3. For load-rating evidence, preserve model/software version, geometry, material properties, deterioration assumptions, loads, boundary conditions, distribution, analysis method, controlling member and result as supplied. Do not recompute or approve a rating unless explicitly authorized by the load rater. 4. Keep scour, fatigue/fracture and impact evidence in distinct lanes with hydraulic/bed survey, detail/cycle, NSTM/fracture-critical, event and inspection capability context. 5. Trace maintenance/restriction recommendations as supplied through owner, implementation, inspection and verification. Quality control and independent quality assurance remain separate reviews and never become traffic authority. Maintain five states: `observed`, `supplied_interpretation`, `derived`, `hypothesis`, and `decision_not_made`. Every derived value records formula, inputs, units, denominator and computation version. Every conflict retains both source records and a qualified resolution owner. Absence, silence and failed retrieval are never positive evidence. ## Parallel branches and join ### Bridge Asset Configuration Authority Analyst Freezes bridge/span/element identity, records, modifications, inspection program and professional authority. - asset and element hierarchy - design/as-built/rehabilitation records - damage and modification chronology - inspection/manual/owner authority Reconcile: - element IDs are unique - records match current configuration - unknown plans remain explicit Stop when: - bridge identity conflict - unresolved modification - inspection authority absent ### Bridge Inspection Condition Defect Analyst Maps material and element observations to reproducible locations, dimensions, evidence and limitations. - deck/superstructure/substructure/foundation observations - corrosion/cracking/section loss/deformation/movement - photo/NDE/access evidence - prior-observation comparison Reconcile: - location and units reproducible - observed and inferred states separated - comparison uses compatible inspection method Stop when: - unlocated critical finding - access limitation hides required area - immediate public-safety observation ### Bridge Load Rating Scour and Fatigue Analyst Traces supplied analysis models, loads, scour, fatigue/fracture and controlling evidence without engineering decisions. - model/input/version provenance - load-rating result as supplied - hydraulic/bed/scour evidence - fatigue/fracture/impact evidence Reconcile: - input/output model trace complete - units and configuration align - rating and scour status are not inferred Stop when: - model baseline absent - material or geometry conflict - rating/posting decision requested ### Bridge Maintenance Action QC QA Analyst Traces findings, owner actions, restrictions as supplied, repair evidence, verification and independent QC/QA. - finding-to-action trace - temporary/permanent measure evidence - implementation and verification - QC versus independent QA Reconcile: - closure has field evidence - QA reviewer is independent - traffic action source is authorized Stop when: - unverified closure - same reviewer claims independence - live traffic or repair action requested ### Bridge Structural Integrity Review Owner Joins asset, inspection, analysis and action/QC-QA evidence into a qualified bridge-owner review pack. - configuration alignment - defect-analysis correlation - critical finding/action trace - independent review queue Reconcile: - every finding resolves to an element - analysis uses current condition - posting/closure/repair remain decision_not_made Stop when: - configuration unresolved - critical evidence gap - qualified bridge authority unavailable Run the root branches independently. The join starts only after all roots return or explicitly stop. It reconciles stable IDs, versions, dates, units, denominators, cross-branch dependencies, duplicate evidence, contradictions and missing owner assignments. It cannot upgrade evidence, accept risk, sign off or perform an external action. ## Reusable assets - `assets/bridge-asset-configuration-authority-baseline.md`: Freeze bridge, span, element, record and authority identity. Required domain fields: bridge_id, span_element_id, route_owner, geometry_material, design_asbuilt_revision, rehabilitation_modification_id, damage_event, inspection_program_revision. - `assets/bridge-inspection-element-condition-defect-ledger.md`: Preserve element observations and limitations. Required domain fields: inspection_id_type, element_location, material, defect_observation, extent_dimension_unit, photo_NDE_locator, access_visibility_limit, prior_comparison. - `assets/bridge-load-rating-scour-fatigue-evidence-register.md`: Trace supplied structural/hydraulic/fatigue analysis evidence. Required domain fields: analysis_id_version, configuration_date, model_software, loads_and_units, material_geometry_assumptions, boundary_distribution, controlling_result_as_supplied, scour_fatigue_evidence. - `assets/bridge-maintenance-restriction-qcqa-action-register.md`: Trace findings through owner-controlled action and independent verification. Required domain fields: finding_id, action_or_restriction_as_supplied, authority_source, work_order_design_revision, implementation_evidence, verification, QC_reviewer, independent_QA_reviewer. - `assets/bridge-structural-integrity-qualified-review-pack.md`: Present configuration, findings, analysis and actions for authorized decisions. Required domain fields: asset_baseline, inspection_status, analysis_status, critical_findings, action_verification, QA_questions, decision_not_made, owner_authority. Read each selected asset before producing output. Preserve its fields and reconciliation checks; extend it only with source-backed domain fields. Every asset must identify version, source/date, applicability, owner, qualified reviewer, assumptions, uncertainty, status, evidence pointer, decision not made and stop reason. ## Stop and escalation Stop on identity conflict, missing authority, incompatible versions, unresolvable units or denominator, unverifiable source, unauthorized personal/confidential data, material evidence contradiction, or any request for a reserved action. Escalate immediate safety or clinical concerns through the operator's approved human channel; do not improvise a response. ## Sources and adaptation boundary Read `references/SOURCE-PROVENANCE.md` and `references/PRIMARY-SOURCES.md` before relying on a method or current requirement. Clean-room method. Rejected zwright8/OpenClaw-Code@ec1b3b08616195dbe709f116bcfc092c009bb753 theater autonomous bridge inspection Skill because no license/NOTICE closes reuse and its military autonomous passage-ranking authority is incompatible. Rejected unlicensed workspace-hub offshore structural Skill. Retained: none; no candidate text copied. Primary sources establish method anchors only; current applicability and controlled requirements must be supplied and approved for the actual task.