Structures post-marketing safety surveillance with signal detection and PSUR reporting. Use when analyzing safety signals, preparing PSURs, or managing pharmacovigilance data.
Instalar com Codex ou Claude Copie este prompt, cole no Codex, Claude ou outro assistente e deixe que ele revise a página da skill e instale para você.
Um comando direto ignora o prompt de revisão. Verifique a origem antes de executá-lo.
Instruções da origem · Visualização somente leitura
name
analyzing-pharmacovigilance-data
description
Structures post-marketing safety surveillance with signal detection and PSUR reporting. Use when analyzing safety signals, preparing PSURs, or managing pharmacovigilance data.
Pharmacovigilance (PV) is the science of detecting, assessing, understanding, and preventing adverse drug reactions after a product reaches the market. Unlike clinical trials with controlled conditions and selected populations, post-marketing surveillance covers millions of diverse patients, making signal detection both critically important and methodologically challenging. Regulatory obligations under 21 CFR 314.80/314.81 (NDA), 21 CFR 600.80 (BLA), EU pharmacovigilance legislation (Regulation 1235/2010, Directive 2010/84/EU), and ICH E2E define the framework. This skill provides the workflow for safety-signal detection, evaluation, PSUR/PBRER preparation, and risk-management planning.
Checkpoint A — Intake and Scoping
Required Intake Questions
What is the marketed product (trade name, INN, formulation, indication)?
What is the data source (spontaneous reports, EHR data, claims databases, registries, published literature)?
What safety database holds the ICSR data (Argus, AriSGlobal, other)?
What is the current MedDRA version for coding?
Is this a routine signal-detection cycle, ad-hoc signal evaluation, or aggregate report (PSUR/PBRER/DSUR)?
What is the data-lock point (DLP) for the reporting period?
Are there active Risk Evaluation and Mitigation Strategies (REMS) or Risk Management Plans (RMP)?
What disproportionality methods are currently in use (PRR, ROR, MGPS, BCPNN)?
Are there known safety signals under evaluation?
What is the target regulatory authority and reporting deadline?
Required Source Documents
Safety database case listings (ICSRs) for the reporting period
Reference Safety Information (RSI) — current product labeling (USPI, SmPC)
Previous PSURs/PBRERs and signal evaluation reports
Published literature search results for the reporting period
Clinical trial safety data (if post-marketing trials ongoing)
Risk Management Plan (EU) or REMS (US) current version
Regulatory correspondence regarding safety issues
Step 1 — Process Individual Case Safety Reports (ICSRs)
Ensure data quality before signal detection:
Case intake: Minimum four elements for a valid ICSR per ICH E2D: identifiable reporter, identifiable patient, suspected medicinal product, suspected adverse reaction
MedDRA coding: Code verbatim reporter terms to MedDRA Preferred Terms (PTs) and map to System Organ Classes (SOCs); apply MedDRA Standardised MedDRA Queries (SMQs) for grouped analyses
Causality assessment: Apply the WHO-UMC system or company-defined algorithm to each case; document the rationale
Seriousness assessment: Classify per ICH E2D criteria (death, life-threatening, hospitalization, disability, congenital anomaly, important medical event)
Expectedness/listedness: Compare the reported reaction against the RSI (USPI for FDA, SmPC for EMA) — unlisted reactions flag potential new signals
Duplicate detection: Run duplicate-detection algorithms (matching patient demographics, event dates, reporter identity) before case enters analysis datasets
Data quality review: Check for completeness (age, sex, indication, dose, time-to-onset, outcome, concomitant medications); query reporters for missing critical information
Step 2 — Conduct Quantitative Signal Detection
Apply disproportionality analysis to the safety database:
Frequentist Methods
Proportional Reporting Ratio (PRR): Signal if PRR ≥ 2 AND chi-squared ≥ 4 AND N ≥ 3 (Evans criteria)
Reporting Odds Ratio (ROR): Analogous to PRR but uses odds ratio; lower 95% CI > 1 flags a signal
Bayesian Methods
Multi-item Gamma Poisson Shrinker (MGPS/EBGM): FDA's preferred method for FAERS data; EB05 (lower 95% CI of EBGM) > 2 flags a signal
Bayesian Confidence Propagation Neural Network (BCPNN/IC): WHO-UMC's method for VigiBase; IC025 > 0 flags a signal
Signal Thresholds
No single statistical threshold defines a signal — disproportionality methods are screening tools, not confirmatory tests
Apply clinical review to all statistical signals before classification
Document the method, database version, data-lock point, and signal-detection parameters
Routine Signal-Detection Cycle
Conduct at defined intervals (monthly, quarterly, or per regulatory requirement)
Compare current-period signals against prior-period results to identify new, strengthened, or resolved signals
Maintain a signal-tracking log with status (new, under evaluation, confirmed, refuted, closed)
Step 3 — Evaluate Identified Signals
For each detected signal, conduct a structured evaluation:
Case-series review: Retrieve all cases coded to the signal PT or SMQ; review for clinical pattern (time-to-onset distribution, dose relationship, dechallenge/rechallenge, concomitant medications, alternative causes)
Biological plausibility: Assess known pharmacology, mechanism of action, preclinical findings, and class effects
Literature review: Search for published case reports, case series, epidemiologic studies, or mechanistic data supporting the association
Epidemiologic data: If available, review comparative safety data from observational databases (CPRD, Sentinel, OMOP-CDM networks)
Clinical trial review: Re-examine safety data from clinical trials for the signal event (may have been overlooked or underpowered)
Regulatory intelligence: Check if other products in the same class have similar signals or labeling changes
Signal Assessment Outcome
Confirmed signal (validated safety concern): Requires risk-benefit reassessment and potential regulatory action
Refuted signal: Evidence does not support a causal association; document rationale and close
Ongoing evaluation: Insufficient data; continue monitoring and specify next evaluation date
Step 4 — Prepare the PSUR/PBRER
For Periodic Benefit-Risk Evaluation Reports (PBRERs) per ICH E2C(R2) or PSURs:
Revise pharmacovigilance plan (routine and additional PV activities)
Update risk-minimization measures (routine and additional)
Submit RMP update with next regulatory procedure or within 6 months of significant new safety information
REMS (US)
Assess whether REMS modifications are needed based on new safety data
Update medication guide, communication plan, or ETASU (Elements to Assure Safe Use) as warranted
Submit REMS modification supplement if required
Labeling Updates
Propose labeling changes (new warnings, precautions, adverse reactions, contraindications) based on confirmed signals
For FDA: CBE-0 supplement (safety labeling changes not requiring prior approval), CBE supplement, or PAS
For EMA: Type II variation for significant labeling changes
Checkpoint B — Pharmacovigilance Review
ICSR data quality meets ICH E2D minimum requirements (four valid elements)
MedDRA coding is consistent and uses the current dictionary version
Disproportionality analysis is conducted with documented methodology and thresholds
All detected signals have a documented evaluation with outcome classification
PBRER/PSUR covers the complete reporting period with accurate exposure estimates
Benefit-risk analysis is structured and balanced
Risk-management instruments (RMP/REMS) are current
Labeling accurately reflects the known safety profile
Regulatory reporting timelines are met (15-day expedited, periodic reports)
Signal-tracking log is current with all open signals under active evaluation
Quality Audit
Safety database is reconciled (no unprocessed cases at DLP)
Duplicate cases have been identified and merged
Causality assessment is documented for every serious case
SMQ application is consistent across reporting periods
Exposure denominators are calculated using the best available method with documented limitations
Literature search strategy is documented and reproducible
PBRER submission meets the EURD list schedule (EU) and NDA/BLA periodic-report schedule (FDA)
All [VERIFY] flags have been resolved or escalated
Guidelines
Disproportionality signals are hypotheses, not proof of causation — clinical evaluation is always required
Absence of a disproportionality signal does not mean absence of risk — spontaneous reporting is subject to underreporting (estimated 1-10% of actual AEs)
Never dismiss a signal based solely on low case counts — rare but serious events (liver failure, anaphylaxis, PML) may have very small numbers
The PBRER is a benefit-risk document, not just a safety summary — benefit evidence must be presented alongside risks
MedDRA coding decisions can materially affect signal detection — standardize coding practices and document any coding conventions
For combination products, assess component-specific and combination-specific safety profiles
Real-world evidence from observational databases complements spontaneous reporting but has its own biases (confounding, channeling, protopathic bias)
Maintain a clear audit trail for all signal-detection runs, evaluation decisions, and regulatory actions
Mark any signal evaluation with uncertain causality with [VERIFY] for qualified PV physician review
This skill produces PV analysis frameworks and reports — final safety conclusions and regulatory actions require Qualified Person for Pharmacovigilance (QPPV) or equivalent sign-off