neqsim-compressor-antisurge-recycle

Set up anti-surge recycle control and coordinated minimum-speed recycle control for centrifugal compressors in NeqSim, including compressor performance chart generation, anti-surge calculation, MinimumSpeedRecycleControllerStructure use for coordinated pressure/speed/recycle split-range control, fuel gas savings, CO2 emission reductions, and monetary cost evaluations. USE WHEN: a task needs to protect a compressor from surge, coordinate speed and recycle valve control at minimum speed, eliminate uncoordinated recycle valve opening, or evaluate power and CO2 savings from control loop optimization.