Skip to main content

abaqus-step

Define analysis steps and procedures. Use when user mentions static analysis, dynamic step, frequency analysis, heat transfer step, or asks about analysis type, time increments, or nlgeom.

跳到安装

来源信息

仓库
JaimeCernuda/abaqus-scripting
最近来源活动
2026年1月28日 21:39
检测到的 SKILL.md 语言
英语
星标
7
分支
1

安装方式

默认使用会先检查来源的 Prompt;你也可以切换为直接命令,或下载本地副本。

检查来源文件

决定是否安装前,请先阅读 SKILL.md,以及 SkillsMP 当前展示的配套文件。

文件资源管理器
4 个文件

正在显示 SKILL.md

SKILL.md
来源说明 · 只读预览
name
abaqus-step
description
Define analysis steps and procedures. Use when user mentions static analysis, dynamic step, frequency analysis, heat transfer step, or asks about analysis type, time increments, or nlgeom.
allowed-tools
["Read","Write","Edit","Glob","Grep","Bash(abaqus:*)"]
# Abaqus Step Skill This skill defines analysis steps and procedures in Abaqus. Steps control what physics are solved and how the solution proceeds. ## When to Use This Skill **Route here when user mentions:** - "static analysis", "dynamic step", "frequency analysis" - "heat transfer step", "thermal step", "transient analysis" - "analysis type", "time increments", "nlgeom" - "convergence issues", "increment size", "time step" - "multi-step analysis", "sequential loading" - "buckling analysis", "modal analysis" - "impact simulation", "crash analysis" **Route elsewhere:** - Applying boundary conditions → `/abaqus-bc` - Applying loads → `/abaqus-load` - Setting up optimization → `/abaqus-optimization` - Configuring output requests → `/abaqus-output` ## Workflow: Creating Analysis Steps ### Step 1: Understand User's Physics Ask if unclear: - **What physics?** Stress, vibration, heat transfer, coupled? - **Static or dynamic?** Constant load vs time-varying? - **Linear or nonlinear?** Small or large deformations? ### Step 2: Choose Step Type | Analysis Goal | Step Type | Key Parameter | |---------------|-----------|---------------| | Stress under constant load | StaticStep | nlgeom=OFF/ON | | Natural frequencies | FrequencyStep | numEigen | | Buckling modes | BuckleStep | numEigen | | Transient dynamics (smooth) | ImplicitDynamicsStep | timePeriod | | Impact/crash | ExplicitDynamicsStep | timePeriod | | Heat conduction | HeatTransferStep | response | | Thermal + structural | CoupledTempDisplacementStep | timePeriod | | Harmonic response | SteadyStateDynamicsStep | frequencyRange | **Most common:** StaticStep with nlgeom=OFF for linear stress analysis. ### Step 3: Determine Linearity | Condition | nlgeom Setting | When | |-----------|----------------|------| | Small deformation, linear material | OFF | Default, fastest | | Large rotation/displacement | ON | Thin structures, cables | | Plasticity | ON | Material yields | | Contact | ON | Parts touching | | Buckling | ON | Post-buckling behavior | ### Step 4: Configure Increment Control | Convergence Difficulty | initialInc | minInc | maxInc | |------------------------|------------|--------|--------| | Easy (linear) | 1.0 | 1e-6 | 1.0 | | Moderate | 0.1 | 1e-8 | 0.2 | | Difficult (contact, plasticity) | 0.01 | 1e-12 | 0.05 | ### Step 5: Chain Multiple Steps (if needed) For sequential loading: 1. First step uses `previous='Initial'` 2. Subsequent steps chain from previous step name 3. Each step can have different physics or settings ## Key Parameters | Parameter | Purpose | Typical Value | |-----------|---------|---------------| | timePeriod | Duration of step | 1.0 for static | | initialInc | Starting increment size | 0.1 for nonlinear | | maxNumInc | Maximum iterations | 100 | | minInc | Smallest allowed increment | 1e-8 | | maxInc | Largest allowed increment | 0.1-1.0 | | numEigen | Modes to extract | 10 | | deltmx | Max temp change per increment | 5.0-10.0 | ## Special Considerations ### Frequency/Modal Analysis - Always from Initial step (no preload needed for basic modal) - Use LANCZOS eigensolver for large models - Extract 10-20 modes typically ### Buckling Analysis - Usually follows a load step (to apply reference load) - Eigenvalues are load multipliers - First positive eigenvalue is critical ### Explicit Dynamics - Time period should be very short (milliseconds) - Increment size determined automatically - Mass scaling may be needed for quasi-static problems ### Heat Transfer - STEADY_STATE for equilibrium temperature - TRANSIENT for time-varying temperature - deltmx controls accuracy vs speed ## Troubleshooting | Problem | Likely Cause | Solution | |---------|--------------|----------| | "Too many increments" | Convergence difficulty | Reduce maxInc, increase maxNumInc | | "Negative eigenvalues" | Unconstrained or unstable | Check BCs, add stabilization | | "Time increment too small" | Severe nonlinearity | Add stabilization, check material | | "Explicit time increment" | Very small elements | Use mass scaling or coarsen mesh | ## Validation Checklist After step creation, verify: - [ ] Step type matches analysis physics - [ ] nlgeom setting appropriate for deformation level - [ ] Increment control parameters reasonable - [ ] Step chains correctly from previous - [ ] Time period appropriate for transient analysis ## Code Patterns For actual API syntax and code examples, see: - [API Quick Reference](references/api-quick-ref.md) - [Common Patterns](references/common-patterns.md) - [Troubleshooting Guide](references/troubleshooting.md)
在 GitHub 查看