Query vapor pressures and NPSH requirements for cavitation assessment
Query thermodynamic properties for 100+ fluids from CoolProp database
Query loss coefficients for pipes, valves, fittings in pump systems
Query fluid viscosities, densities, and material properties vs temperature
Access atmospheric properties and aerospace fluid data from NASA Earthdata
Query high-accuracy thermodynamic properties from NIST REFPROP database (commercial)
| name | fluids-package |
| description | Pipe flow, pump sizing, friction factor, and compressible flow calculations |
| category | packages |
| domain | fluids |
| complexity | intermediate |
| dependencies | ["fluids","scipy"] |
The fluids library is a comprehensive Python package for mechanical and chemical engineers working with fluid flow problems. It provides validated correlations and functions for:
The library implements over 100 correlations from the literature with extensive validation against published test cases.
pip install fluids
For full functionality including optimization routines:
pip install fluids[complete]
Core utilities and dimensional analysis functions.
Friction factor calculations for pipe flow including:
Pump performance calculations:
Compressible flow calculations:
Pressure drop through valves, fittings, and pipe components.
The Reynolds number (Re) determines flow regime and is fundamental to all pipe flow calculations.
from fluids.core import Reynolds
# For pipe flow: Re = ρVD/μ
Re = Reynolds(V=2.5, D=0.05, rho=1000, mu=0.001)
# Result: 125000 (turbulent flow)
# Interpretation:
# Re < 2300: Laminar flow
# 2300 < Re < 4000: Transition
# Re > 4000: Turbulent flow
The friction factor (f) is used in the Darcy-Weisbach equation: ΔP = f(L/D)(ρV²/2)
from fluids.friction import friction_factor
# Colebrook-White correlation (implicit, most accurate)
f = friction_factor(Re=125000, eD=0.0001) # eD = roughness/diameter
# Result: ~0.0178
# Moody correlation (explicit approximation)
from fluids.friction import friction_factor_Moody
f_moody = friction_factor_Moody(Re=125000, eD=0.0001)
# For laminar flow (Re < 2300):
f_laminar = friction_factor(Re=1500, eD=0.0001)
# Result: 0.0427 (f = 64/Re)
Calculate pressure drop and head loss in piping systems.
from fluids.friction import friction_factor, head_from_P
from fluids.core import Reynolds
# Given: Water flow through steel pipe
D = 0.1 # m, pipe diameter
L = 100 # m, pipe length
V = 2.0 # m/s, velocity
rho = 1000 # kg/m³, density
mu = 0.001 # Pa·s, viscosity
epsilon = 0.000045 # m, roughness (steel)
# Step 1: Calculate Reynolds number
Re = Reynolds(V=V, D=D, rho=rho, mu=mu)
# Step 2: Calculate friction factor
eD = epsilon / D
f = friction_factor(Re=Re, eD=eD)
# Step 3: Calculate pressure drop
# Darcy-Weisbach: ΔP = f(L/D)(ρV²/2)
dP = f * (L/D) * (rho * V**2 / 2)
# Step 4: Convert to head loss
h_loss = head_from_P(dP, rho) # meters of fluid
print(f"Reynolds: {Re:.0f}")
print(f"Friction factor: {f:.5f}")
print(f"Pressure drop: {dP:.0f} Pa")
print(f"Head loss: {h_loss:.2f} m")
Relate pump performance at different speeds and impeller diameters.
from fluids.pump import affinity_law_volume, affinity_law_head, affinity_law_power
# Original pump operating point
Q1 = 100 # m³/h, flow rate
H1 = 50 # m, head
P1 = 20 # kW, power
N1 = 1450 # rpm, speed
D1 = 0.3 # m, impeller diameter
# New speed
N2 = 1750 # rpm
# Affinity laws (constant impeller diameter):
# Q2/Q1 = N2/N1
# H2/H1 = (N2/N1)²
# P2/P1 = (N2/N1)³
Q2 = affinity_law_volume(Q1, N1, N2)
H2 = affinity_law_head(H1, N1, N2)
P2 = affinity_law_power(P1, N1, N2)
print(f"New flow: {Q2:.1f} m³/h")
print(f"New head: {H2:.1f} m")
print(f"New power: {P2:.1f} kW")
Specific speed (Ns) characterizes pump type and efficiency.
from fluids.pump import specific_speed
# Pump operating conditions
Q = 0.05 # m³/s, flow rate
H = 40 # m, head
N = 1450 # rpm, rotational speed
# Calculate specific speed (dimensionless)
Ns = specific_speed(Q, H, N)
# Interpretation:
# Ns < 0.5: Centrifugal (radial flow)
# 0.5 < Ns < 1.0: Francis (mixed flow)
# 1.0 < Ns < 4.0: Propeller (axial flow)
print(f"Specific speed: {Ns:.2f}")
if Ns < 0.5:
pump_type = "Centrifugal (radial flow)"
elif Ns < 1.0:
pump_type = "Francis (mixed flow)"
else:
pump_type = "Propeller (axial flow)"
print(f"Recommended pump type: {pump_type}")
For gas flow in pipes and nozzles.
from fluids.compressible import Mach
# Calculate Mach number from velocity
V = 200 # m/s, velocity
c = 340 # m/s, speed of sound in air at 15°C
Ma = Mach(V, c)
# Result: 0.588
# Flow classification:
# Ma < 0.3: Incompressible
# 0.3 < Ma < 0.8: Subsonic
# 0.8 < Ma < 1.2: Transonic
# Ma > 1.2: Supersonic
Determine if flow is choked in a nozzle or orifice.
from fluids.compressible import P_critical_flow
# Gas properties
P_upstream = 500000 # Pa, upstream pressure
k = 1.4 # heat capacity ratio (air)
# Critical pressure for choked flow
P_crit = P_critical_flow(P=P_upstream, k=k)
# Result: ~264,000 Pa
# If downstream pressure < P_crit, flow is choked
P_downstream = 200000 # Pa
if P_downstream < P_crit:
print("Flow is choked - mass flow is at maximum")
print(f"Critical pressure: {P_crit:.0f} Pa")
else:
print("Flow is not choked")
import numpy as np
from fluids.friction import friction_factor
from fluids.core import Reynolds
import matplotlib.pyplot as plt
def system_curve(Q_range, static_head, pipe_specs):
"""
Calculate system head curve for a piping system.
Parameters:
-----------
Q_range : array, flow rates (m³/s)
static_head : float, static lift (m)
pipe_specs : dict with keys:
- L: pipe length (m)
- D: pipe diameter (m)
- epsilon: roughness (m)
- rho: fluid density (kg/m³)
- mu: fluid viscosity (Pa·s)
Returns:
--------
H_system : array, required head at each flow rate (m)
"""
L = pipe_specs['L']
D = pipe_specs['D']
rho = pipe_specs['rho']
mu = pipe_specs['mu']
epsilon = pipe_specs['epsilon']
# Calculate cross-sectional area
A = np.pi * D**2 / 4
H_system = np.zeros_like(Q_range)
for i, Q in enumerate(Q_range):
if Q == 0:
H_system[i] = static_head
continue
# Calculate velocity
V = Q / A
# Reynolds number
Re = Reynolds(V=V, D=D, rho=rho, mu=mu)
# Friction factor
eD = epsilon / D
f = friction_factor(Re=Re, eD=eD)
# Friction head loss (Darcy-Weisbach)
h_friction = f * (L/D) * (V**2 / (2*9.81))
# Total system head
H_system[i] = static_head + h_friction
return H_system
# Define system
pipe_specs = {
'L': 200, # m
'D': 0.15, # m
'epsilon': 0.000045, # m (steel)
'rho': 1000, # kg/m³
'mu': 0.001 # Pa·s
}
static_head = 30 # m
# Generate system curve
Q_range = np.linspace(0, 0.1, 50) # m³/s
H_system = system_curve(Q_range, static_head, pipe_specs)
# Example pump curve (quadratic fit)
# H = H0 - A*Q - B*Q²
H0 = 80 # m, shutoff head
A = 200 # head loss coefficient
B = 3000 # quadratic coefficient
H_pump = H0 - A*Q_range - B*Q_range**2
# Find operating point (intersection)
idx = np.argmin(np.abs(H_pump - H_system))
Q_op = Q_range[idx]
H_op = H_system[idx]
print(f"Operating Point:")
print(f" Flow rate: {Q_op*3600:.1f} m³/h ({Q_op:.4f} m³/s)")
print(f" Head: {H_op:.1f} m")
# Verification: At Q=0.05 m³/s
# V = Q/A = 0.05/(π*0.15²/4) = 2.83 m/s
# Re = 1000*2.83*0.15/0.001 = 424,500 (turbulent)
# f ≈ 0.0175 (from Moody chart)
# h_f = 0.0175*(200/0.15)*(2.83²/(2*9.81)) = 9.5 m
# H_total = 30 + 9.5 = 39.5 m ✓
from fluids.pump import affinity_law_volume, affinity_law_head
def parallel_pumps(Q_total, n_pumps, single_pump_curve):
"""
Calculate operating point for parallel pump configuration.
For pumps in parallel:
- Flow rates add: Q_total = n * Q_single
- Head remains the same: H_total = H_single
"""
# Single pump flow rate
Q_single = Q_total / n_pumps
# Head from single pump curve
H = single_pump_curve(Q_single)
return Q_single, H
# Single pump curve: H = 60 - 500*Q² (simplified)
def pump_curve(Q):
return 60 - 500*Q**2
# System requires 150 m³/h at 40 m head
Q_required = 150/3600 # m³/s
n_pumps = 2
Q_single, H_operating = parallel_pumps(Q_required, n_pumps, pump_curve)
print(f"Parallel Pump Configuration ({n_pumps} pumps):")
print(f" Total flow: {Q_required*3600:.1f} m³/h")
print(f" Flow per pump: {Q_single*3600:.1f} m³/h")
print(f" Operating head: {H_operating:.1f} m")
# Verification:
# Each pump delivers 75 m³/h (0.0208 m³/s)
# H = 60 - 500*(0.0208)² = 60 - 0.22 = 59.8 m ✓
from fluids.friction import friction_factor, friction_factor_laminar
# Test Case 1: Laminar Flow (Poiseuille)
# Analytical solution: f = 64/Re
Re_laminar = 1000
f_calculated = friction_factor(Re=Re_laminar, eD=0)
f_analytical = 64/Re_laminar
print("Test 1: Laminar Flow")
print(f" Re = {Re_laminar}")
print(f" f (calculated) = {f_calculated:.6f}")
print(f" f (analytical) = {f_analytical:.6f}")
print(f" Error = {abs(f_calculated - f_analytical):.9f}")
assert abs(f_calculated - f_analytical) < 1e-9, "Laminar flow test failed"
print(" ✓ PASSED\n")
# Test Case 2: Turbulent Flow - Smooth Pipe
# From Moody diagram: Re=1e5, smooth pipe → f ≈ 0.0183
Re_turbulent = 1e5
f_smooth = friction_factor(Re=Re_turbulent, eD=0)
print("Test 2: Turbulent Flow (Smooth Pipe)")
print(f" Re = {Re_turbulent:.0f}")
print(f" f (calculated) = {f_smooth:.6f}")
print(f" f (Moody chart) ≈ 0.0183")
print(f" Error = {abs(f_smooth - 0.0183):.6f}")
assert abs(f_smooth - 0.0183) < 0.0005, "Smooth pipe test failed"
print(" ✓ PASSED\n")
# Test Case 3: Turbulent Flow - Rough Pipe
# Commercial steel: ε/D = 0.0002, Re = 1e6 → f ≈ 0.0144
Re_rough = 1e6
eD_rough = 0.0002
f_rough = friction_factor(Re=Re_rough, eD=eD_rough)
print("Test 3: Turbulent Flow (Rough Pipe)")
print(f" Re = {Re_rough:.0f}")
print(f" ε/D = {eD_rough}")
print(f" f (calculated) = {f_rough:.6f}")
print(f" f (Moody chart) ≈ 0.0144")
print(f" Error = {abs(f_rough - 0.0144):.6f}")
assert abs(f_rough - 0.0144) < 0.0005, "Rough pipe test failed"
print(" ✓ PASSED\n")
# Test Case 4: From Crane TP-410 (Standard reference)
# Example 4-9: Water in 6-inch Schedule 40 pipe
D = 0.1541 # m (6-inch Schedule 40 ID)
V = 3.05 # m/s
rho = 998 # kg/m³
mu = 0.001 # Pa·s
epsilon = 0.000045 # m (steel)
Re_crane = Reynolds(V=V, D=D, rho=rho, mu=mu)
eD_crane = epsilon/D
f_crane = friction_factor(Re=Re_crane, eD=eD_crane)
# Crane TP-410 gives f ≈ 0.0172
print("Test 4: Crane TP-410 Example 4-9")
print(f" Re = {Re_crane:.0f}")
print(f" ε/D = {eD_crane:.6f}")
print(f" f (calculated) = {f_crane:.6f}")
print(f" f (Crane TP-410) ≈ 0.0172")
print(f" Error = {abs(f_crane - 0.0172):.6f}")
assert abs(f_crane - 0.0172) < 0.0003, "Crane TP-410 test failed"
print(" ✓ PASSED\n")
print("All friction factor tests passed! ✓")
from fluids.compressible import isothermal_gas
# Gas pipeline calculation
# Problem: Natural gas (methane) pipeline
P1 = 5e6 # Pa, inlet pressure
T = 288.15 # K, temperature (15°C)
L = 50000 # m, pipeline length (50 km)
D = 0.5 # m, diameter
m = 10 # kg/s, mass flow rate
MW = 16.04 # g/mol, molecular weight (CH4)
k = 1.31 # heat capacity ratio
# Calculate outlet pressure using isothermal flow
# This accounts for friction and compressibility
from fluids.compressible import isothermal_gas
P2 = isothermal_gas(rho=None, P1=P1, P2=None, L=L, D=D, m=m,
T=T, Z=1, fd=0.012) # Assuming f=0.012
print("Gas Pipeline Calculation:")
print(f" Inlet pressure: {P1/1e6:.2f} MPa")
print(f" Outlet pressure: {P2/1e6:.2f} MPa")
print(f" Pressure drop: {(P1-P2)/1e6:.2f} MPa")
print(f" Length: {L/1000:.0f} km")
print(f" Mass flow: {m:.1f} kg/s")
| Material | Roughness ε (m) |
|---|---|
| Drawn tubing | 0.0000015 |
| Commercial steel | 0.000045 |
| Galvanized iron | 0.00015 |
| Cast iron | 0.00026 |
| Concrete | 0.0003 to 0.003 |
| Riveted steel | 0.0009 to 0.009 |