| Oscillation / unexpected peak | Unstable (\Gamma_\mathrm{in})/(\Gamma_\mathrm{out}), bias resonance | Stability circles; bias network impedance sweep below band |
| Gain lower than sim | Cable/fixture loss, wrong reference plane, cold bias | De-embed; re-measure bias voltages/currents |
| Gain hole/narrow notch | Filter spurious mode, cable resonance, test artifact | Time-domain gating; EM mode plot; swap cables |
| High NF | Loss before LNA, poor match at NF(_\mathrm{min}), noisy bias | Friis budget; source pull for NF(_\mathrm{min}) |
| Poor IP3 vs datasheet | Wrong tone spacing/power, oscillation, compression | Reduce input power; verify two-tone setup |
| High EVM floor | Phase noise, IQ imbalance, PA compression, group delay ripple | Step tests: back off power, narrow BW, bypass blocks |
| PLL won't lock | Loop bandwidth, charge pump, divider error, VCO range | Transient sim; tune detector; measure Vtune |
| High PLL spurs | Fractional-N, reference feedthrough, poor decoupling | Spectrum at (f_\mathrm{ref}) offsets; loop filter redesign |
| RL degraded in band | Match drift, damaged component, wrong ε(_r) in fab | Compare to golden board; verify stackup |
| mmWave non-repeatability | Probe contact, shim height, substrate mode | TRL cal repeatability; compare on-wafer vs packaged |
| PA thermal shutdown | Insufficient heat sink, bias runaway, VSWR | IR camera; coupler VSWR; load-pull contour |
| Duplexer isolation fail | TX coupling path, enclosure resonance, poor grounding | Near-field probe; EM cavity modes |
| Image response in RX | Insufficient image reject filter or IQ imbalance | Measure image frequency directly with offset LO |
| AM-PM distortion in PA | Class-AB bias, memory effects, envelope ripple | AM-AM/AM-PM curves; supply filtering |
| VCO pushing excessive | Poor supply filtering, load pull on output | Measure freq vs (V_\mathrm{dd}); isolate with buffer |
| Balun mode conversion | Unbalanced layout, poor ground | Mixed-mode S-parameters; even-mode spur check |