Port MATLAB Data Acquisition Toolbox code from the discouraged (legacy) session-based interface (daq.createSession, addAnalogInputChannel, startBackground, DataAvailable listeners, queueOutputData, wait) to the recommended DataAcquisition interface (daq("ni"), addinput, start, ScansAvailableFcn, write, preload). Use when migrating legacy DAQ scripts, converting session-API calls, working with DataAcquisition objects, writing multi-feature DAQ scripts that combine triggers, callbacks, continuous acquisition, or analog output. Also use when a user says their DAQ script "used to work" or "errors on R20XX", since modernizing legacy session-API code is a frequent fix for those failures. Trigger keywords: daq, DAQ, NI, session interface, addtrigger, addclock, ScansAvailableFcn, ScansRequiredFcn, daq.createSession, addAnalogInputChannel, startBackground, queueOutputData, DataAvailable, evt.Data, evt.TimeStamps, wait(d), preload, discouraged, legacy, modernize, R2020a.
Standardmäßig ist der Prompt ausgewählt, der zuerst die Quelle prüft. Sie können zu einem direkten Befehl wechseln oder eine lokale Kopie herunterladen.
Quelldateien prüfen
Lesen Sie SKILL.md und alle von SkillsMP angezeigten Begleitdateien, bevor Sie sich für eine Installation entscheiden.
Mit Codex oder Claude installieren Kopieren Sie diesen Prompt, fügen Sie ihn in Codex, Claude oder einen anderen Assistant ein und lassen Sie die Skill-Seite prüfen und installieren.
Ein direkter Befehl überspringt den Prüf-Prompt. Prüfen Sie die Quelle, bevor Sie ihn ausführen.
Port MATLAB Data Acquisition Toolbox code from the discouraged (legacy) session-based interface (daq.createSession, addAnalogInputChannel, startBackground, DataAvailable listeners, queueOutputData, wait) to the recommended DataAcquisition interface (daq("ni"), addinput, start, ScansAvailableFcn, write, preload). Use when migrating legacy DAQ scripts, converting session-API calls, working with DataAcquisition objects, writing multi-feature DAQ scripts that combine triggers, callbacks, continuous acquisition, or analog output. Also use when a user says their DAQ script "used to work" or "errors on R20XX", since modernizing legacy session-API code is a frequent fix for those failures. Trigger keywords: daq, DAQ, NI, session interface, addtrigger, addclock, ScansAvailableFcn, ScansRequiredFcn, daq.createSession, addAnalogInputChannel, startBackground, queueOutputData, DataAvailable, evt.Data, evt.TimeStamps, wait(d), preload, discouraged, legacy, modernize, R2020a.
Port DAQ Code to the Modern DataAcquisition Interface
Translate legacy session-based Data Acquisition Toolbox code (daq.createSession, addAnalogInputChannel, DataAvailable listeners, startBackground, queueOutputData, wait) to the modern DataAcquisition interface introduced in R2020a (daq("ni"), , , , , ). Also covers writing new multi-feature DAQ scripts where the modern API patterns are easy to get wrong under cognitive load.
addinput
ScansAvailableFcn
start
write
preload
When to Use
Porting an existing script that calls daq.createSession, addAnalogInputChannel, addAnalogOutputChannel, addCounterInputChannel, addCounterOutputChannel, or addDigitalChannel.
Writing a new DAQ script that combines two or more of: external triggers, continuous acquisition, callback-driven streaming, analog output with refill, or cross-callback state.
Debugging errors like Undefined function 'wait' for input arguments of type 'daq.interfaces.DataAcquisition' or Unrecognized method, property, or field 'Data' for class 'matlabshared.asyncio.buffer.ElementsAvailableInfo'.
When NOT to Use
Single-channel foreground acquisition with no trigger and no callbacks (e.g. "acquire 1 s of voltage from ai0 at 10 kHz and plot"). The modern API is straightforward at this scale and this skill would be unnecessary overhead.
Picking a DAQ vendor or evaluating non-NI hardware. This skill's evidence base is NI.
Signal processing or analysis of already-acquired data (filtering, spectral analysis, etc.). This skill only covers acquiring and generating data through the DataAcquisition interface, not post-processing it.
Simulink, App Designer, or real-time-target DAQ workflows.
Modernizing matlab.unittest test suites or framework-style test classes (parameterized fixtures, assumeTrue gating, arity-contract tests, helper-class hierarchies). The API substitutions in this skill apply, but the test-harness scaffolding (parent-class stripping, fixture redesign, retiring tests that target removed contracts) is out of scope. Use this skill to translate the API calls inside test bodies, then make the harness-level judgment calls separately.
Workflow
When porting a session-based script or composing a new multi-feature DAQ script, follow this order. Verify after every step — most failure modes in this domain are silent.
Inventory the legacy script (porting only). Identify: device(s), channel types, rate, continuous vs finite, trigger/clock connections, callbacks (DataAvailable/DataRequired/ErrorOccurred), state shared across callbacks, output queueing.
Translate vocabulary. Map every session-API token to its modern counterpart. Consult references/session-to-modern-mapping.md — load it whenever a session-API token appears in the legacy script. Common silent-rename traps: NotifyWhenDataAvailableExceeds → ScansAvailableFcnCount, NumberOfScans/NumScans → implicit (no equivalent argument), ExternalTriggerTimeout → DigitalTriggerTimeout, IsContinuous=true → start(d, "Continuous") argument.
Build the DataAcquisition object.d = daq("ni"), set d.Rate, add channels with addinput/addoutput. Apply per-channel properties via the channel handle returned by addinput/addoutput.
Wire triggers and clocks. Use references/canonical-snippets.md §1 — load it when the script involves addtrigger or addclock. Argument order is (d, type, role, trigSrc, trigDest) — Source is 4th, Destination is 5th. Verify: the returned trigger object's Source and Destination fields show what you intended.
Wire callbacks. Use canonical snippets §2 — load it when the script needs ScansAvailableFcn or ScansRequiredFcn. Inside the callback, always pull data via read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix") — the evt argument is matlabshared.asyncio.buffer.ElementsAvailableInfo and exposes only NumElementsAvailable, no Data, no TimeStamps. Strongly recommend wiring d.ErrorOccurredFcn = @(~,evt) fprintf("DAQ error: %s\n", evt.Error.message) — without it, exceptions inside other callbacks are silently swallowed and the run "succeeds" while every fire throws. For strict ports where the legacy script had no ErrorOccurred listener, surface this trade-off to the user instead of silently adding the handler — let them opt in.
Pick a state-sharing pattern (callbacks only). If a callback needs to maintain state across fires (running counters, phase accumulator, latch flags), see references/callback-state-patterns.md — load it any time a callback maintains state. Default: handle-class wrapper or nested function. Avoid src.UserData.X = src.UserData.X + ... field-mutation; it does not persist.
Wire the lifecycle. Use canonical snippets §3 — load it when blocking on completion. There is no wait(d) method on the modern object. For finite acquisitions, prefer start(d, "Duration", seconds(N)) then read or a Running poll. For continuous, set a stop condition inside the callback (if scansRead >= target; stop(src); end) and poll d.Running from the caller.
Run verifyDataAcquisition before live execution. Script: scripts/verifyDataAcquisition.m. Catches the four highest-frequency silent gaps (missing ErrorOccurredFcn, evt.Data in callback source, wait(d) token, UserData.X = UserData.X + ... field mutation) by inspecting the live object and grepping the source file. Run via mcp__matlab__run_matlab_file if available, or copy into the user's project.
Live verification. Run a short version (e.g. 1–2 s instead of the user's full duration). Check that the script reaches start cleanly, that the callback fires at least once, and that no errors print from ErrorOccurredFcn. Use mcp__matlab__run_matlab_file against a saved .m file, not mcp__matlab__evaluate_matlab_code — the eval-string buffer runs in script mode and rejects local/nested function definitions, which Pattern 5 and most callback bodies require.
The five canonical patterns below appear in full, with verified code, in references/canonical-snippets.md. Inline below is the minimal recall snippet for each — enough to anchor the agent's memory under load. Load the reference for the full, runnable forms.
The 4th argument is the Source ("External" for an external signal). The 5th is the Destination (the device terminal). Reversing them is the most-frequent error in this domain. The trigger condition ("RisingEdge", "FallingEdge") is set on the trigger object returned by addtrigger (trg.Condition), not on the DataAcquisition object. There is no d.DigitalTriggerCondition property — inventing one passes static lint but errors at runtime.
Pattern 2: ScansAvailableFcn body — pull data via read, never evt.Data
The evt argument carries only NumElementsAvailable; it has no Data or TimeStamps. Wiring ErrorOccurredFcn is strongly recommended — without it, callback exceptions are silently swallowed and the run "succeeds" while every fire throws. For strict ports of legacy scripts that did not have an ErrorOccurred listener, ask the user before adding one rather than inserting it silently.
Pattern 3: Block until acquisition completes — there is no wait(d)
start(d, "Duration", seconds(10));
while d.Running
pause(0.05);
end
wait(d) does not exist on daq.interfaces.DataAcquisition. Poll d.Running, or rely on start(d, "Duration", ...) + a stop condition inside the callback.
Pattern 4: Continuous AO playback with auto-refill
preload is output-only — calling it on input-only setups errors. Two preloaded blocks before start give the buffer headroom for the first ScansRequiredFcn to fire.
Pattern 5: Cross-callback state via nested function or handle class
function runStreamingAcquisition()
d = daq("ni");
addinput(d, "Dev1", "ai0", "Voltage");
d.Rate = 1000;
d.ScansAvailableFcnCount = 200;
scansRead = 0;
target = d.Rate * 5;
d.ScansAvailableFcn = @(src, ~) onBlock(src);
d.ErrorOccurredFcn = @(~, evt) fprintf("DAQ error: %s\n", evt.Error.message);
start(d, "Continuous");
while d.Running
pause(0.05);
end
function onBlock(src)
data = read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix");
scansRead = scansRead + size(data, 1);
if scansRead >= target
stop(src);
end
end
end
Nested function captures scansRead by reference, so updates persist across fires. Do not use src.UserData.X = src.UserData.X + ... — that pattern does not persist; counters reset every fire and closed-loop control silently outputs zero forever. Full alternatives (handle class, full UserData rewrite) and their tradeoffs are in references/callback-state-patterns.md.
Conventions
Strongly recommend wiring d.ErrorOccurredFcn whenever any other *Fcn callback is set, since the listener swallows callback exceptions otherwise. For strict ports of legacy scripts that lacked an ErrorOccurred listener, surface the trade-off to the user rather than silently adding the handler — adding it is a defensible default but fidelity to the source is also defensible.
Always pull data via read(src, src.ScansAvailableFcnCount, "OutputFormat", "Matrix") inside ScansAvailableFcn. Never reach for evt.Data or evt.TimeStamps.
Always verify the returned trigger object after addtrigger — confirm Source and Destination reflect intent.
Never use wait(d). Poll d.Running or use start(d, "Duration", ...).
Never mutate fields of d.UserData from inside a callback (src.UserData.X = src.UserData.X + ...). State must live in a closure-captured variable, a handle-class wrapper, or a whole-struct rewrite of UserData.
Never call preload on an input-only DataAcquisition. It is output-only.
Preferstart(d, "Duration", seconds(N)) over start(d, "NumScans", N) for finite acquisition. NumScans is silently coerced or ignored.
Prefer the modern function names: daqlist over daq.getDevices, daqreset over daq.reset, daq("ni") over daq.createSession('ni').
No such method on daq.interfaces.DataAcquisition. Throws.
while d.Running, pause(0.05); end
src.UserData.Counter = src.UserData.Counter + n
Field mutation through src.UserData does not persist across callback fires.
Closure variable in nested function, or handle-class wrapper. See callback-state-patterns.md.
preload(d, ...) on a DAQ with only input channels
preload is output-only.
For inputs, just call start(d, ...). No prepare/preload step needed.
start(d, "NumScans", 1000)
NumScans is ignored — emits warning. Buffer size determined by preload or read.
start(d, "Duration", seconds(N)), or rely on preload size.
s.IsContinuous = true; s.startBackground();
Both are session-API. Modern API has no IsContinuous property.
start(d, "Continuous")
addlistener(d, 'DataAvailable', @cb)
Listener events were renamed to *Fcn properties on the object.
d.ScansAvailableFcn = @cb
s.queueOutputData(block)
Session-API. Modern API uses preload (initial) and write (refill).
preload(d, block) before start; write(d, block) from ScansRequiredFcn.
References
references/session-to-modern-mapping.md — full rename table for every function and property that is commonly ported verbatim by mistake. Load whenever a session-API token appears in the legacy script.
references/canonical-snippets.md — minimal, self-contained, runnable forms of the five patterns above. Load when composing a multi-feature script and you want a verified anchor.
references/callback-state-patterns.md — four state-sharing options (UserData / closure / handle-class / nested function), when to pick which, and the silent failure modes of the wrong choice. Load when any callback needs cross-fire state.
scripts/verifyDataAcquisition.m — static-checks a DataAcquisition object and its source script before live execution. Returns a structured report flagging the four highest-frequency silent gaps.