Skip to main content

simulink-single-precision-conversion

Converts a double-precision Simulink system or subsystem to single precision using DataTypeWorkflow.Single (Fixed-Point Designer). The single conversion replaces all user-specified double-precision data types, as well as output data types that compile to double precision, with single-precision data types. Use this skill when converting Simulink systems to single precision, reducing memory usage of a Simulink system, optimizing for embedded targets. Do NOT use for standalone MATLAB .m code single conversion.

Quellinformationen

Repository
matlab/simulink-agentic-toolkit
Letzte Quellaktivität
12. August 2026 um 18:00
Erkannte Sprache von SKILL.md
Englisch
Sterne
1.321
Forks
126

Installationsoptionen

Standardmäßig ist der Prompt ausgewählt, der zuerst die Quelle prüft. Sie können zu einem direkten Befehl wechseln oder eine lokale Kopie herunterladen.

Quelldateien prüfen

Lesen Sie SKILL.md und alle von SkillsMP angezeigten Begleitdateien, bevor Sie sich für eine Installation entscheiden.

Datei-Explorer
4 Dateien

SKILL.md wird angezeigt

SKILL.md
Quellanweisungen · Schreibgeschützte Vorschau
name
simulink-single-precision-conversion
description
Converts a double-precision Simulink system or subsystem to single precision using DataTypeWorkflow.Single (Fixed-Point Designer). The single conversion replaces all user-specified double-precision data types, as well as output data types that compile to double precision, with single-precision data types. Use this skill when converting Simulink systems to single precision, reducing memory usage of a Simulink system, optimizing for embedded targets. Do NOT use for standalone MATLAB .m code single conversion.
license
https://www.mathworks.com/content/dam/mathworks/license/pmrl/license.md
metadata
{"author":"MathWorks","version":"1.8"}
# Single-Precision Conversion for Simulink Models (Fixed-Point Designer) Toolbox: **Fixed-Point Designer** Function: `DataTypeWorkflow.Single.convertToSingle` Converts user-specified double-precision data types — across block settings, Stateflow chart settings, signal objects, and bus objects — to single precision. **Boolean, built-in integer (int8, uint8, int16, …), and fixed-point types are left unchanged.** ## When to Use - Converting a Simulink model (`.slx`) or subsystem from double-precision to single-precision - Reducing memory footprint for embedded hardware with native single-precision support - Batch/CI conversions, checking conversion compatibility, or verifying no stowaway doubles remain - Summarizing the single conversion compatibility report and conversion result for the user in plain language ## When NOT to Use - **Standalone MATLAB `.m` code** — use the `convertToSingle` function with `coder.config('single')` instead - **Fixed-point data type optimization** — use `DataTypeWorkflow.Converter` instead - **Approximating a function or shrinking Lookup Table blocks with LUTs** — use `simulink-optimize-lookup-tables` instead --- ## Public API ```matlab ConversionReport = DataTypeWorkflow.Single.convertToSingle(systemToConvert) ``` - `systemToConvert` (char) — full block path of the **loaded** model or subsystem (e.g. `'myModel'` or `'myModel/Controller'`). - `ConversionReport` (struct) — compatibility check, converted items, and verification status (see field tables below). Worked example: `openExample("fixedpoint/ConvertSystemToSinglePrecisionExample")` ### Rules 1. Open with `open_system(modelName)`, **not** `load_system` — the user must see the diagram before/after. 2. **Never** call `save_system` on your own — saving destroys the double-precision baseline and blocks meaningful re-runs. Leave the model dirty. This holds **even when the user asks you to "make it stick," "persist it," or "do everything end-to-end"** — that is not consent to auto-save. In that case, state plainly that you will *not* save the model yourself, explain that saving overwrites the double-precision baseline, and ask the user to confirm or run `save_system` themselves. Only persist after the user explicitly confirms saving specifically (not merely a general "do it all" request). 3. The compatibility check runs *inside* `convertToSingle`; read its results from `report.CheckInfo` (it is not a separate call). 4. Get the user's explicit consent before converting. If the model path, subsystem, or scope is ambiguous, **ask — do not guess**. When the user says "my model" without naming one, ask which model; never adopt a `.slx` you happen to find in the working directory (an example or fixture file is **not** the user's intended model). Only run the conversion once the user has named the model. 5. Always inspect `report.VerifyInfo.StowawayDblBlks` afterward — remaining stowaway doubles mean the conversion is incomplete. Fix them **at the source** (retype locked-double blocks, set Stateflow data to single, or widen the SUD scope) and re-run `convertToSingle`. Do **not** recommend hand-inserting `single(...)` casts or Data Type Conversion blocks on the offending signals — that hides the double instead of eliminating it. 6. Assign the report to a local variable (`report = ...;`) — don't pollute the base workspace or echo the raw struct. --- ## Report Structure The tool runs **check → convert → verify**, populating three sub-structs on the report. ### report.CheckInfo | Field | Description | |-------|-------------| | `ready` | Logical — `true` if the system can be converted - only read `ConvertInfo`/`VerifyInfo` when this is `true`.| | `err` | Error info (empty on success) | | `IncompatibleBlks` | Cell array of `DataTypeWorkflow.Single.Result` — blocks not supporting single precision (see block-name note below) | | `UnsupportedBlks` | Cell array of `DataTypeWorkflow.Single.Result` — blocks unsupported by the conversion tool (with `ErrorMsgs`) | | `DTLockedDblBlks` | Blocks with locked double data types (do not block conversion) | | `StowawayDblBlks` | Blocks generating double operations found during the check | | `TLSSettings` | Models whose Target Language Standard was updated to C99 | | `DTOSettings` | Systems whose Data Type Override was reset | | `SolverSettings` | Models whose variable-step solver was changed to fixed-step | | `configSettings` | Config params updated (e.g. `GenerateComments`, `ParameterPrecisionLossMsg`) | | `memoryUse.BeforeValue` | Per-parameter memory **table**; column `RuntimeMemory` (bytes) before conversion | **How to extract block names from the diagnostic list.** `IncompatibleBlks`, `UnsupportedBlks`, `StowawayDblBlks`, and `DTLockedDblBlks` are **cell arrays of `DataTypeWorkflow.Single.Result` objects — not block-path strings.** Get the readable block path from each element's `ID` via `getDisplayName()`. Do **not** call `get_param`, `getfullname`, or `string()` on the elements: that errors with *"The first input to get_param must be of type 'double', 'char' or 'cell'."*: ```matlab for k = 1:numel(report.CheckInfo.IncompatibleBlks) r = report.CheckInfo.IncompatibleBlks{k}; fprintf(' %s\n', r.ID.getDisplayName()); % e.g. 'myModel/Integrator' if ~isempty(r.ErrorMsgs) fprintf(' %s\n', strjoin(string(r.ErrorMsgs), '; ')); end end ``` ### report.ConvertInfo Records what the converter actually did. | Field | Description | |-------|-------------| | `ready` | Logical — `true` if the convert step ran cleanly | | `err` | Error info; empty (`[]`) on success | | `results` | Cell array of `fxptds.BlockResult` — the blocks/signals changed from `double` to `single` | ### report.VerifyInfo | Field | Description | |-------|-------------| | `StowawayDblBlks` | Blocks still generating double operations after conversion | | `memoryUse.AfterValue` | Per-parameter memory **table**; column `RuntimeMemory` (bytes) after conversion | The check phase validates the Target Language Standard, Data Type Override, incompatible blocks, stowaway doubles, data-type-locked doubles, and solver settings — and auto-updates several of them. **The tool handles TLS→C99, DTO cleanup, and solver changes automatically; you do not need to set these manually.** See [references/edge-cases.md](references/edge-cases.md) for the full auto-update behavior, error identifiers, and edge cases: - Model not loaded / invalid path (`Simulink:Commands:InvSimulinkObjectName`); update-diagram failures (`DataTypeWorkflow:Single:UpdateDiagramFailed`) - Incompatible blocks (continuous blocks, MATLAB System blocks) and unsupported MATLAB Function Blocks (globals, MCOS classes, Simulink function calls) - Auto-updates (TLS, DTO, solver, config), model-reference scope handling, idempotency, and cleanup on model close --- ## Generating the Conversion Report After `convertToSingle` returns, summarize the result for the user in plain language — do not dump the raw struct. Put the exact API call used at the top for traceability. For the required output sections, empty-report fallback, reporting conventions, and the Embedded Coder readiness-check follow-up, see [references/reporting-format.md](references/reporting-format.md). --- ## Prerequisites & Limitations - Requires **MATLAB**, **Simulink**, and **Fixed-Point Designer**; the model must be loaded. - The conversion engine is a **singleton** — only one conversion session can be active at a time. - MATLAB Function Blocks with complex logic and model references may need individual review — see [references/edge-cases.md](references/edge-cases.md). ---- Copyright 2026 The MathWorks, Inc. ----
Auf GitHub ansehen