| name | building-simulink-models |
| description | Builds and edits Simulink, System Composer, Stateflow, and Simscape models. Use when modifying model structure, parameters, ports, connections, or Stateflow chart internals. |
| license | https://www.mathworks.com/content/dam/mathworks/license/pmrl/license.md |
| metadata | {"author":"MathWorks","version":"1.5"} |
Building Models
Use model_edit for all structural changes — Simulink, System Composer, Simscape, and Stateflow chart internals
When to Use
- Adding, connecting, deleting, or replacing blocks in a model
- Configuring block parameters, signal properties, or model settings
- Creating or editing Stateflow chart internals (states, transitions, junctions, data, events, messages, functions)
- Building System Composer architecture models
- Wiring Simscape physical connections
When NOT to Use
- Querying parameter values → use
model_query_params
- Resolving variable references to numeric values → use
model_resolve_params
Library & Policy Prerequisites — BLOCKING GATE
Do this FIRST — evaluate the result before any other tool call. Do not narrate the gate check to the user; proceed silently based on the result.
Call library.settingsLookup() to check for custom library configuration. It returns a struct with resolved absolute paths:
found — whether a libraries file was located (satk-libraries.json or legacy reuse-libraries.json)
enabled — whether custom libraries are configured
gatePass — whether the gate is satisfied (can proceed to build)
kgIndexPath — absolute path to library-kg/index.md
librariesPath — absolute path to the libraries file
policyPath — absolute path to block-policy.json
dataRoot — absolute path to the directory containing .satk/
Interpret the result:
found: false → no custom libraries configured. Proceed with standard Simulink blocks.
gatePass: true, found: true → read kgIndexPath for block lookup, then plan and edit.
gatePass: false → invoke setup-custom-libraries to populate the Knowledge Index.
Display meaningful description of each check and result instead of stating gate Pass/fail.
No model reading, planning, or editing begins until the gate passes.
Workflow
- Ensure Library & Policy Prerequisites: See BLOCKING GATE above. Do not proceed until gates pass.
- Library block lookup: List every block type you plan to use, search
.satk/library-kg/index.md and the relevant category pages to find each of the library blocks that match.
- Read first: Use
model_read on the target scope to get block IDs and understand existing topology.
- Plan the data flow: For complex edits, sketch inputs → operations → outputs, then map to blocks identified in Step 1 & 2.
- Edit: Use
model_edit with operations scoped to one subsystem level at a time.
- Verify: Use
model_read on the scope to confirm the structure matches your intent.
- Check connectivity: After all edits in a scope are complete, run
model_check to catch unconnected ports or dangling lines. Fix any error-severity issues.
If model_edit returns status: partial: Run both model_read and model_check immediately — don't wait until all edits are complete.
Operation Chaining with ref
Use ref to name a block and #ref to reference it in later operations within the same call:
[{"op": "add_block", "type": "Gain", "name": "MyGain", "ref": "g1"},
{"op": "connect", "target": "blk_5.y1 -> #g1.u1"}]
In SF scope, #ref references are portless — no .y1/.u1 suffixes (see references/stateflow.md).
The response created map shows ref → blk_id (or ref → sf_X in SF scope). In subsequent calls, use the returned ID — #ref only works within a single call.
Guardrails
Naming Conventions
Prefer code-generation-safe names for blocks, signals, and variables:
- Use only:
a-z, A-Z, 0-9, underscore (_)
- Don't start with a number
- Don't use leading/trailing or consecutive underscores
- Prefer names under 32 characters (required for some code generation targets)
Block Types
Use the block's display name in the type field. Do not construct or guess library paths.
-
Custom library blocks (from satk-libraries.json): pass both type AND ReferenceBlock fields. Set type to the block's display name and ReferenceBlock to the full library path from the library KG.
-
Toolbox KB blocks (from activeToolboxes): Use them exactly like custom library blocks — reference the type and ReferenceBlock fields from the toolbox category page in the library KG.
-
Built-in Simulink blocks: Use the BlockType directly: Gain, Sum, Constant, Integrator, SubSystem, Scope
-
Library blocks (Simscape, Aerospace, DSP, Communications, etc.): Use the display name as it appears in the Simulink Library Browser: Voltage Source, Resistor, DC Motor, Solver Configuration, 6DOF (Euler Angles)
-
If model_edit returns INVALID_TYPE: Fall back to the full library path from MATLAB documentation (e.g., ee_lib/Sources/Voltage Source)
[{"op": "add_block", "type": "In", "ReferenceBlock": "customLib_Portsandsubsystems/In", "name": "Voltage", "ref": "v1"},
{"op": "add_block", "type": "Gain", "ReferenceBlock": "customLib_Mathoperations/Gain", "name": "Kp", "ref": "g1"},
{"op": "add_block", "type": "Add", "ReferenceBlock": "customLib_Mathoperations/Add", "name"
[{"op": "add_block", "type": "Voltage Source", "name": "V1", "ref": "v1"},
{"op": "add_block", "type": "Resistor", "name": "R1", "ref": "r1"},
{"op": "add_block", "type": "Electrical Reference", "name": "Gnd", "ref": "gnd"},
{"op": "add_block", "type"
Review Gate
After completing all edits for a scope, verify:
- No
error-severity issues from model_check (unconnected ports, dangling lines)
- All
ref names resolved to blk_id in the created map — no dangling #ref references in subsequent calls
- Stateflow charts pass lint (
model_check with checks='["stateflow_lint"]') before layout is applied
- If
model_edit returned status: partial at any point, confirm the scope is now structurally complete via model_read
Domain-Specific Rules
When working with these domains, read the corresponding reference file before editing:
- Stateflow charts ->
references/stateflow.md — model_edit edits chart internals natively. Scope to a chart (sf_X or chart blk_X) and use the same operations: add_block for SF elements, portless connect for transitions, configure for properties. The reference covers SF-specific syntax, scoping, LabelString patterns, and the two-call SL+SF workflow.
- System Composer architecture models ->
references/system-composer.md — Create models with systemcomposer.createModel, then use model_edit. Components use type: "SubSystem", ports use Bus Element blocks. The reference covers component creation, port wiring, and behavior model generation.
- Simscape physical models ->
references/simscape.md — Physical connections use bidirectional <-> syntax. The reference covers connection semantics, port patterns, and initial target variables.