Skip to main content

medical-device-compliance

Use when developing, manufacturing, or selling medical devices, IVDs, software as a medical device (SaMD), or wellness products that cross the medical-device threshold in any market - covers EU MDR/IVDR, FDA 510(k)/PMA/De Novo, UKCA MDR, classification, Notified Body selection, UDI, post-market surveillance

Aller à l'installation

Informations de source

Dépôt
Cleo-Labs-IA/skills_library
Dernière activité de la source
28 mai 2026 à 11:15
Langue détectée de SKILL.md
anglais
Étoiles
1
Forks
1

Options d'installation

Le prompt qui vérifie d'abord la source est sélectionné par défaut. Vous pouvez passer à une commande directe ou télécharger une copie locale.

Vérifiez les fichiers source

Lisez SKILL.md et les fichiers associés affichés par SkillsMP avant de décider de l'installer.

Affichage de SKILL.md

SKILL.md
Instructions source · Aperçu en lecture seule
name
medical-device-compliance
description
Use when developing, manufacturing, or selling medical devices, IVDs, software as a medical device (SaMD), or wellness products that cross the medical-device threshold in any market - covers EU MDR/IVDR, FDA 510(k)/PMA/De Novo, UKCA MDR, classification, Notified Body selection, UDI, post-market surveillance
# Medical Device Compliance Full regulatory workflow for medical devices, IVDs, and software as a medical device (SaMD). EU MDR/IVDR, FDA, UKCA, classification, clinical evaluation, post-market. ## Decision Flow ```dot digraph { rankdir=TB; node [shape=box style=rounded fontsize=10]; qualify [label="1. Qualify as medical device\n(MDR Art. 2, FDA 201(h))"]; classify [label="2. Classify:\nEU I/IIa/IIb/III, FDA I/II/III"]; pathway [label="3. Choose pathway:\nself-cert / NB / 510(k) / PMA / De Novo"]; qms [label="4. QMS ISO 13485\n+ Risk mgmt ISO 14971"]; clinical [label="5. Clinical evaluation\n(MEDDEV 2.7/1 rev 4)"]; tech [label="6. Technical Documentation\n(MDR Annex II/III)"]; audit [label="7. NB audit / 510(k) review\n/ PMA submission"]; udi [label="8. UDI assignment\n+ EUDAMED registration"]; pms [label="9. Post-Market Surveillance\nplan + PMCF"]; sell [label="10. Place on market"]; qualify -> classify -> pathway -> qms -> clinical -> tech -> audit -> udi -> pms -> sell; } ``` ## EU -- MDR 2017/745 | Requirement | Detail | |-------------|--------| | **Legal basis** | Regulation (EU) 2017/745 (MDR) -- fully applicable since 26 May 2021. Transitional provisions to 26 Dec 2027 (Class III/IIb implantables) and 31 Dec 2028 (other Class IIa/IIb/Im/Is/Ir) per Reg 2023/607 | | **Classification** | Annex VIII rules 1-22. Class I (low risk), IIa (medium), IIb (medium-high), III (high risk). Software per Rule 11 (most clinical SaMD = Class IIa minimum) | | **Pathway** | Class I non-sterile/non-measuring: self-declaration. Class Is/Im/Ir: Notified Body for sterility/measurement/reusable aspect only. Class IIa+: full NB conformity assessment (Annex IX or X) | | **Notified Body** | ~50 NB designated under MDR (vs 80+ under old MDD). 18-24 month wait times. List: NANDO database | | **Technical Documentation** | MDR Annex II + III: device description, design info, GSPR checklist (Annex I), risk management ISO 14971, verification/validation, clinical evaluation, labeling, PMS plan | | **Clinical evaluation** | MDR Article 61 + Annex XIV. MEDDEV 2.7/1 rev 4 still referenced. Equivalence routes restricted under MDR. Implants + Class III need own clinical investigations | | **QMS** | ISO 13485:2016 required. Annex IX requires NB to audit QMS | | **UDI** | Basic UDI-DI + UDI-DI (production identifier). Carrier: GS1, HIBCC, ICCBBA. Direct marking on reusable devices | | **EUDAMED** | EU database. Modules: Actor registration (live), UDI/Device (live but voluntary), NB/Certificate (live), Clinical Investigation (partial), Vigilance (live), PMS (pending). Mandatory use phased | | **Authorized Representative** | Non-EU manufacturers MUST appoint EU AR (MDR Article 11) | | **Timeline** | Class I: 1-3 months. Class IIa: 8-14 months (incl. NB wait). Class IIb: 12-18 months. Class III: 18-36 months | | **Cost** | Class I: EUR 5,000-30,000. Class IIa: EUR 50,000-200,000 + NB fees EUR 30,000-100,000/year. Class III: EUR 500,000-2,000,000+ | ## EU -- IVDR 2017/746 (In Vitro Diagnostics) | Requirement | Detail | |-------------|--------| | **Legal basis** | Reg (EU) 2017/746 -- date of application 26 May 2022. Transition extended by Reg 2024/1860: Class D to Dec 2027, Class C to Dec 2028, Class B to Dec 2029, Class A sterile to Dec 2029 | | **Classification** | 7 rules (Annex VIII). Class A (low, self-cert), B (medium-low, NB for QMS), C (medium-high, NB full), D (high risk, NB + EU Reference Lab) | | **Massive shift from IVDD** | ~80% of IVDs now require NB involvement (was ~20% under IVDD). Critical NB capacity shortage | | **CS (Common Specifications)** | Mandatory for Class D devices. Annex I performance + safety | | **Performance evaluation** | Analytical + clinical performance + scientific validity. PER (Performance Evaluation Report) | | **In-house exception** | IVDs manufactured and used within the same health institution exempt from CE marking but must meet GSPRs and document compliance | | **Cost** | Class A: EUR 10,000-50,000. Class B: EUR 50,000-150,000. Class C/D: EUR 150,000-800,000 + | ## US -- FDA Pathways | Pathway | Use | Timeline | User Fee FY2026 | |---------|-----|----------|-----------------| | **510(k) Premarket Notification** | Class II (most). Demonstrate substantial equivalence to predicate. Class III by 510(k) for grandfathered devices | 90-day FDA target (actual: 4-9 months) | $24,335 standard; $6,084 small business | | **PMA (Premarket Approval)** | Class III high-risk devices (e.g., implantable defibrillators, life-sustaining) | 180-day FDA target (actual: 12-24 months) | $507,505 standard; $126,876 small business | | **De Novo** | Novel low/moderate risk devices with no predicate. Pathway to Class I/II for new device types | 150-day FDA target (actual: 10-18 months) | $172,553 standard; $43,138 small business | | **510(k) exempt** | ~75% of Class I devices and many Class II. Still subject to general controls + listing | Immediate | $0 (only listing fee $9,280 annual establishment) | | **HDE (Humanitarian Device Exemption)** | Rare diseases <8,000 patients/year US. Limited evidence | 75-day FDA target | $4,867 | | **Breakthrough Devices** | Designation accelerates review for serious conditions | -- | Same as 510(k)/PMA + priority | ### FDA Classification | Class | Risk | Controls | Examples | |-------|------|----------|----------| | **Class I** | Low | General controls only | Tongue depressors, exam gloves, manual stethoscopes | | **Class II** | Moderate | General + special controls (510(k) usually required) | Powered wheelchairs, infusion pumps, blood pressure monitors | | **Class III** | High | PMA required | Heart valves, implantable pacemakers, deep brain stimulators | ### FDA Software (SaMD) - Software functions that meet the definition of a "device" under section 201(h) regulated - 21st Century Cures Act 2016 excluded certain wellness software, EHR functions - Pre-Cert pilot program ended 2023; FDA returning to traditional 510(k) for SaMD - AI/ML: PCCP (Predetermined Change Control Plan) framework finalized 2024 -- allows pre-authorized algorithm updates ## UK -- UKCA / UK MDR | Requirement | Detail | |-------------|--------| | **Legal basis** | UK Medical Devices Regulations 2002 (as amended). New UK MDR consultation 2024-2026 to align/diverge from EU MDR | | **CE acceptance** | CE marked devices accepted in GB until 30 June 2030 (extended by Statutory Instrument 2024) | | **UKCA marking** | Required if new UK-specific routes used. Limited UK Approved Bodies (BSI UK, SGS UK, TUV SUD UK) | | **UKRP** | UK Responsible Person required for non-UK manufacturers (since Jan 2021). Must be GB-established. Functions equivalent to EU AR | | **MHRA registration** | All devices placed on UK market must be registered with MHRA. Free for Class I, EUR 100-240 for higher classes | | **Northern Ireland** | EU MDR/IVDR apply (Northern Ireland Protocol). CE marking only | ## Post-Market Obligations ### EU MDR/IVDR PMS | Tool | Frequency | |------|-----------| | **PMS Plan** | Mandatory per device (Annex III) | | **PSUR (Periodic Safety Update Report)** | Class IIa: every 2 years. Class IIb/III: annually. Submit to EUDAMED | | **PMCF (Post-Market Clinical Follow-up)** | Mandatory unless justified absence. Plan + report cycle | | **Vigilance (Article 87)** | Serious incident: report within 15 days. Death/serious deterioration: within 10 days. Trend reporting: as soon as identified | | **Field Safety Corrective Action** | FSCA + Field Safety Notice -- public communication of safety issue | ### FDA Post-Market | Tool | Detail | |------|--------| | **MDR (Medical Device Reporting)** | 21 CFR 803. Manufacturer: 30-day MDR (death/serious injury) or 5-day MDR (urgent remedial action). User facility: 10-day report | | **Recalls** | FDA-required (rare) or voluntary. 21 CFR 7 | | **Post-market studies (522 orders)** | FDA can require post-approval studies | | **MedWatch** | FDA voluntary reporting system | ## Key Standards | Standard | Purpose | |----------|---------| | **ISO 13485:2016** | Medical device QMS. Mandatory for CE marking, expected by FDA | | **ISO 14971:2019** | Risk management. Mandatory for CE/FDA | | **IEC 62366-1:2015** | Usability engineering | | **IEC 60601-1** (4th edition) | Electrical medical equipment safety | | **IEC 62304:2006+A1:2015** | Medical device software lifecycle | | **ISO 10993** series | Biological evaluation of medical devices | | **ISO 11135 / 11137** | Sterilization (EO / radiation) | | **MEDDEV 2.7/1 rev 4** | Clinical evaluation guidance | ## Common Compliance Traps - **Wellness vs medical device threshold**: "General wellness" software exempt under 21st Century Cures Act ONLY if not for disease diagnosis/treatment. "Heart health monitor" claims = medical device. - **Software classification trap**: MDR Rule 11 pushes nearly all software providing information used for decision-making to Class IIa minimum. Self-declaration NOT possible. - **IVDR self-certified to NB shock**: 80% of IVDs moved to NB requirement under IVDR. Capacity is the bottleneck (only 12 NB designated under IVDR as of 2025). - **510(k) substantial equivalence overreach**: Selecting a predicate that uses different technology/indications = FDA Refuse-to-Accept letter. RTA happens in ~30% of submissions. - **Missing PMCF plan justification**: Under MDR, "no PMCF needed" requires positive justification per Annex XIV Part B Section 6. Cannot just say "low risk". - **UDI direct marking**: Reusable Class IIa/IIb/III devices need UDI directly marked on the device (etching, laser). Many small manufacturers overlook this. ## MCP Integration ``` mcp__claude_ai_Cleo_Insight__search_signals(q="MDR transition", country="EU") mcp__claude_ai_Cleo_Insight__search_signals(q="FDA 510k", country="US") mcp__claude_ai_Cleo_Insight__get_regulation(id="2017/745") # EU MDR mcp__claude_ai_Cleo_Insight__get_regulation(id="2017/746") # EU IVDR mcp__claude_ai_CLEO_LEGAL_API__compliance/check product_description: "wearable ECG monitor with AI arrhythmia detection" target_markets: ["EU", "US", "UK"] ``` ## Power This With the Cleo Legal API Medical device compliance involves MDR (174 articles), IVDR (113 articles), FDA 21 CFR Parts 800-1299, UK MDR 2002 (constantly amended), 200+ harmonized standards, EUDAMED + GUDID databases, Notified Body certification status (changes weekly). A typical product launch touches 15+ regulatory documents. **With the Cleo Legal API at https://legaldata-public.cleolabs.co:** - `GET /v2/catalog/regulations?vertical=medical_device&country=EU,US,UK` — MDR, IVDR, FDA pathways, UK MDR + harmonized standards mapped - `POST /v2/medical/classify` — feed intended use + technical features, get MDR class (Rules 1-22) + FDA class + UK class in one call - `GET /v2/medical/notified-bodies?scope=mdr_iia` — current list of NBs designated for each MDR scope code (NB designations change quarterly) - `POST /v2/medical/predicate-search` — for FDA 510(k), find candidate predicates from 510(k) database - `POST /v2/webhooks?topic=mdr_transition,fda_guidance,nb_designation` — MDR/IVDR transition deadlines, FDA guidance docs, NB scope changes **Get started:** ``` # 1. Sign up for free at https://legaldata-public.cleolabs.co # 2. Get your API key (3 lifetime requests free, then EUR 349/mo for 1M) # 3. Install the MCP server: claude mcp add cleo-legal-api https://api.legaldata.cleolabs.co/mcp \ --header "Authorization: Bearer ld_live_YOUR_KEY" ``` Tested ROI: For a SaMD company launching across EU+US+UK, the API replaces ~40 hours of MDR Annex VIII rule parsing + 510(k) predicate research + UK MDR divergence tracking per device. ## Common Mistakes - **Confusing CE for general use**: A device that is CE marked under MDR is NOT automatically authorized in US (FDA), UK (UKCA post-2030), Switzerland, or other markets. - **Skipping clinical evaluation update**: CE under MDR requires updating clinical evaluation EVERY year for Class III/implants, every 2 years for Class IIa/IIb. Missing this = certificate suspension. - **AR/UKRP overlap confusion**: One legal entity can be both EU AR and UK RP only if established in both jurisdictions (Brexit complication). - **EUDAMED voluntary trap**: Some modules voluntary now -- but UDI/registration becomes mandatory once Commission declares EUDAMED fully functional (expected late 2026). - **Wellness device pivot**: Adding ANY diagnostic claim to wellness wearable = medical device. Marketing materials must align with cleared/CE-marked indications. - **ISO 13485 not enough alone**: ISO 13485 is QMS only. MDR requires QMS PLUS clinical evidence PLUS technical file PLUS PMS system. Cert alone = not CE marking. ## Cross-references - `claims-substantiation` -- general wellness vs medical claim boundary - `electronics-compliance` -- IEC 60601 overlap with LVD/EMC for electromedical devices - `labeling-compliance` -- MDR Annex I Chapter III labelling + UDI - `product-safety-incident` -- MDR vigilance vs general product safety overlap - `regulatory-calendar` -- MDR/IVDR transition deadlines, PSUR cycles, certificate renewals
Voir sur GitHub