medical-device-compliance

Use when developing, manufacturing, or selling medical devices, IVDs, software as a medical device (SaMD), or wellness products that cross the medical-device threshold in any market - covers EU MDR/IVDR, FDA 510(k)/PMA/De Novo, UKCA MDR, classification, Notified Body selection, UDI, post-market surveillance

跳到安装

来源信息

仓库
Cleo-Labs-IA/skills_library
最近来源活动
2026年5月28日 11:15
检测到的 SKILL.md 语言
英语
星标
1
分支
1

安装方式

默认使用会先检查来源的 Prompt;你也可以切换为直接命令,或下载本地副本。

检查来源文件

决定是否安装前,请先阅读 SKILL.md,以及 SkillsMP 当前展示的配套文件。

正在显示 SKILL.md

SKILL.md
来源说明 · 只读预览
name
medical-device-compliance
description
Use when developing, manufacturing, or selling medical devices, IVDs, software as a medical device (SaMD), or wellness products that cross the medical-device threshold in any market - covers EU MDR/IVDR, FDA 510(k)/PMA/De Novo, UKCA MDR, classification, Notified Body selection, UDI, post-market surveillance
# Medical Device Compliance Full regulatory workflow for medical devices, IVDs, and software as a medical device (SaMD). EU MDR/IVDR, FDA, UKCA, classification, clinical evaluation, post-market. ## Decision Flow ```dot digraph { rankdir=TB; node [shape=box style=rounded fontsize=10]; qualify [label="1. Qualify as medical device\n(MDR Art. 2, FDA 201(h))"]; classify [label="2. Classify:\nEU I/IIa/IIb/III, FDA I/II/III"]; pathway [label="3. Choose pathway:\nself-cert / NB / 510(k) / PMA / De Novo"]; qms [label="4. QMS ISO 13485\n+ Risk mgmt ISO 14971"]; clinical [label="5. Clinical evaluation\n(MEDDEV 2.7/1 rev 4)"]; tech [label="6. Technical Documentation\n(MDR Annex II/III)"]; audit [label="7. NB audit / 510(k) review\n/ PMA submission"]; udi [label="8. UDI assignment\n+ EUDAMED registration"]; pms [label="9. Post-Market Surveillance\nplan + PMCF"]; sell [label="10. Place on market"]; qualify -> classify -> pathway -> qms -> clinical -> tech -> audit -> udi -> pms -> sell; } ``` ## EU -- MDR 2017/745 | Requirement | Detail | |-------------|--------| | **Legal basis** | Regulation (EU) 2017/745 (MDR) -- fully applicable since 26 May 2021. Transitional provisions to 26 Dec 2027 (Class III/IIb implantables) and 31 Dec 2028 (other Class IIa/IIb/Im/Is/Ir) per Reg 2023/607 | | **Classification** | Annex VIII rules 1-22. Class I (low risk), IIa (medium), IIb (medium-high), III (high risk). Software per Rule 11 (most clinical SaMD = Class IIa minimum) | | **Pathway** | Class I non-sterile/non-measuring: self-declaration. Class Is/Im/Ir: Notified Body for sterility/measurement/reusable aspect only. Class IIa+: full NB conformity assessment (Annex IX or X) | | **Notified Body** | ~50 NB designated under MDR (vs 80+ under old MDD). 18-24 month wait times. List: NANDO database | | **Technical Documentation** | MDR Annex II + III: device description, design info, GSPR checklist (Annex I), risk management ISO 14971, verification/validation, clinical evaluation, labeling, PMS plan | | **Clinical evaluation** | MDR Article 61 + Annex XIV. MEDDEV 2.7/1 rev 4 still referenced. Equivalence routes restricted under MDR. Implants + Class III need own clinical investigations | | **QMS** | ISO 13485:2016 required. Annex IX requires NB to audit QMS | | **UDI** | Basic UDI-DI + UDI-DI (production identifier). Carrier: GS1, HIBCC, ICCBBA. Direct marking on reusable devices | | **EUDAMED** | EU database. Modules: Actor registration (live), UDI/Device (live but voluntary), NB/Certificate (live), Clinical Investigation (partial), Vigilance (live), PMS (pending). Mandatory use phased | | **Authorized Representative** | Non-EU manufacturers MUST appoint EU AR (MDR Article 11) | | **Timeline** | Class I: 1-3 months. Class IIa: 8-14 months (incl. NB wait). Class IIb: 12-18 months. Class III: 18-36 months | | **Cost** | Class I: EUR 5,000-30,000. Class IIa: EUR 50,000-200,000 + NB fees EUR 30,000-100,000/year. Class III: EUR 500,000-2,000,000+ | ## EU -- IVDR 2017/746 (In Vitro Diagnostics) | Requirement | Detail | |-------------|--------| | **Legal basis** | Reg (EU) 2017/746 -- date of application 26 May 2022. Transition extended by Reg 2024/1860: Class D to Dec 2027, Class C to Dec 2028, Class B to Dec 2029, Class A sterile to Dec 2029 | | **Classification** | 7 rules (Annex VIII). Class A (low, self-cert), B (medium-low, NB for QMS), C (medium-high, NB full), D (high risk, NB + EU Reference Lab) | | **Massive shift from IVDD** | ~80% of IVDs now require NB involvement (was ~20% under IVDD). Critical NB capacity shortage | | **CS (Common Specifications)** | Mandatory for Class D devices. Annex I performance + safety | | **Performance evaluation** | Analytical + clinical performance + scientific validity. PER (Performance Evaluation Report) | | **In-house exception** | IVDs manufactured and used within the same health institution exempt from CE marking but must meet GSPRs and document compliance | | **Cost** | Class A: EUR 10,000-50,000. Class B: EUR 50,000-150,000. Class C/D: EUR 150,000-800,000 + | ## US -- FDA Pathways | Pathway | Use | Timeline | User Fee FY2026 | |---------|-----|----------|-----------------| | **510(k) Premarket Notification** | Class II (most). Demonstrate substantial equivalence to predicate. Class III by 510(k) for grandfathered devices | 90-day FDA target (actual: 4-9 months) | $24,335 standard; $6,084 small business | | **PMA (Premarket Approval)** | Class III high-risk devices (e.g., implantable defibrillators, life-sustaining) | 180-day FDA target (actual: 12-24 months) | $507,505 standard; $126,876 small business | | **De Novo** | Novel low/moderate risk devices with no predicate. Pathway to Class I/II for new device types | 150-day FDA target (actual: 10-18 months) | $172,553 standard; $43,138 small business | | **510(k) exempt** | ~75% of Class I devices and many Class II. Still subject to general controls + listing | Immediate | $0 (only listing fee $9,280 annual establishment) | | **HDE (Humanitarian Device Exemption)** | Rare diseases <8,000 patients/year US. Limited evidence | 75-day FDA target | $4,867 | | **Breakthrough Devices** | Designation accelerates review for serious conditions | -- | Same as 510(k)/PMA + priority | ### FDA Classification | Class | Risk | Controls | Examples | |-------|------|----------|----------| | **Class I** | Low | General controls only | Tongue depressors, exam gloves, manual stethoscopes | | **Class II** | Moderate | General + special controls (510(k) usually required) | Powered wheelchairs, infusion pumps, blood pressure monitors | | **Class III** | High | PMA required | Heart valves, implantable pacemakers, deep brain stimulators | ### FDA Software (SaMD) - Software functions that meet the definition of a "device" under section 201(h) regulated - 21st Century Cures Act 2016 excluded certain wellness software, EHR functions - Pre-Cert pilot program ended 2023; FDA returning to traditional 510(k) for SaMD - AI/ML: PCCP (Predetermined Change Control Plan) framework finalized 2024 -- allows pre-authorized algorithm updates ## UK -- UKCA / UK MDR | Requirement | Detail | |-------------|--------| | **Legal basis** | UK Medical Devices Regulations 2002 (as amended). New UK MDR consultation 2024-2026 to align/diverge from EU MDR | | **CE acceptance** | CE marked devices accepted in GB until 30 June 2030 (extended by Statutory Instrument 2024) | | **UKCA marking** | Required if new UK-specific routes used. Limited UK Approved Bodies (BSI UK, SGS UK, TUV SUD UK) | | **UKRP** | UK Responsible Person required for non-UK manufacturers (since Jan 2021). Must be GB-established. Functions equivalent to EU AR | | **MHRA registration** | All devices placed on UK market must be registered with MHRA. Free for Class I, EUR 100-240 for higher classes | | **Northern Ireland** | EU MDR/IVDR apply (Northern Ireland Protocol). CE marking only | ## Post-Market Obligations ### EU MDR/IVDR PMS | Tool | Frequency | |------|-----------| | **PMS Plan** | Mandatory per device (Annex III) | | **PSUR (Periodic Safety Update Report)** | Class IIa: every 2 years. Class IIb/III: annually. Submit to EUDAMED | | **PMCF (Post-Market Clinical Follow-up)** | Mandatory unless justified absence. Plan + report cycle | | **Vigilance (Article 87)** | Serious incident: report within 15 days. Death/serious deterioration: within 10 days. Trend reporting: as soon as identified | | **Field Safety Corrective Action** | FSCA + Field Safety Notice -- public communication of safety issue | ### FDA Post-Market | Tool | Detail | |------|--------| | **MDR (Medical Device Reporting)** | 21 CFR 803. Manufacturer: 30-day MDR (death/serious injury) or 5-day MDR (urgent remedial action). User facility: 10-day report | | **Recalls** | FDA-required (rare) or voluntary. 21 CFR 7 | | **Post-market studies (522 orders)** | FDA can require post-approval studies | | **MedWatch** | FDA voluntary reporting system | ## Key Standards | Standard | Purpose | |----------|---------| | **ISO 13485:2016** | Medical device QMS. Mandatory for CE marking, expected by FDA | | **ISO 14971:2019** | Risk management. Mandatory for CE/FDA | | **IEC 62366-1:2015** | Usability engineering | | **IEC 60601-1** (4th edition) | Electrical medical equipment safety | | **IEC 62304:2006+A1:2015** | Medical device software lifecycle | | **ISO 10993** series | Biological evaluation of medical devices | | **ISO 11135 / 11137** | Sterilization (EO / radiation) | | **MEDDEV 2.7/1 rev 4** | Clinical evaluation guidance | ## Common Compliance Traps - **Wellness vs medical device threshold**: "General wellness" software exempt under 21st Century Cures Act ONLY if not for disease diagnosis/treatment. "Heart health monitor" claims = medical device. - **Software classification trap**: MDR Rule 11 pushes nearly all software providing information used for decision-making to Class IIa minimum. Self-declaration NOT possible. - **IVDR self-certified to NB shock**: 80% of IVDs moved to NB requirement under IVDR. Capacity is the bottleneck (only 12 NB designated under IVDR as of 2025). - **510(k) substantial equivalence overreach**: Selecting a predicate that uses different technology/indications = FDA Refuse-to-Accept letter. RTA happens in ~30% of submissions. - **Missing PMCF plan justification**: Under MDR, "no PMCF needed" requires positive justification per Annex XIV Part B Section 6. Cannot just say "low risk". - **UDI direct marking**: Reusable Class IIa/IIb/III devices need UDI directly marked on the device (etching, laser). Many small manufacturers overlook this. ## MCP Integration ``` mcp__claude_ai_Cleo_Insight__search_signals(q="MDR transition", country="EU") mcp__claude_ai_Cleo_Insight__search_signals(q="FDA 510k", country="US") mcp__claude_ai_Cleo_Insight__get_regulation(id="2017/745") # EU MDR mcp__claude_ai_Cleo_Insight__get_regulation(id="2017/746") # EU IVDR mcp__claude_ai_CLEO_LEGAL_API__compliance/check product_description: "wearable ECG monitor with AI arrhythmia detection" target_markets: ["EU", "US", "UK"] ``` ## Power This With the Cleo Legal API Medical device compliance involves MDR (174 articles), IVDR (113 articles), FDA 21 CFR Parts 800-1299, UK MDR 2002 (constantly amended), 200+ harmonized standards, EUDAMED + GUDID databases, Notified Body certification status (changes weekly). A typical product launch touches 15+ regulatory documents. **With the Cleo Legal API at https://legaldata-public.cleolabs.co:** - `GET /v2/catalog/regulations?vertical=medical_device&country=EU,US,UK` — MDR, IVDR, FDA pathways, UK MDR + harmonized standards mapped - `POST /v2/medical/classify` — feed intended use + technical features, get MDR class (Rules 1-22) + FDA class + UK class in one call - `GET /v2/medical/notified-bodies?scope=mdr_iia` — current list of NBs designated for each MDR scope code (NB designations change quarterly) - `POST /v2/medical/predicate-search` — for FDA 510(k), find candidate predicates from 510(k) database - `POST /v2/webhooks?topic=mdr_transition,fda_guidance,nb_designation` — MDR/IVDR transition deadlines, FDA guidance docs, NB scope changes **Get started:** ``` # 1. Sign up for free at https://legaldata-public.cleolabs.co # 2. Get your API key (3 lifetime requests free, then EUR 349/mo for 1M) # 3. Install the MCP server: claude mcp add cleo-legal-api https://api.legaldata.cleolabs.co/mcp \ --header "Authorization: Bearer ld_live_YOUR_KEY" ``` Tested ROI: For a SaMD company launching across EU+US+UK, the API replaces ~40 hours of MDR Annex VIII rule parsing + 510(k) predicate research + UK MDR divergence tracking per device. ## Common Mistakes - **Confusing CE for general use**: A device that is CE marked under MDR is NOT automatically authorized in US (FDA), UK (UKCA post-2030), Switzerland, or other markets. - **Skipping clinical evaluation update**: CE under MDR requires updating clinical evaluation EVERY year for Class III/implants, every 2 years for Class IIa/IIb. Missing this = certificate suspension. - **AR/UKRP overlap confusion**: One legal entity can be both EU AR and UK RP only if established in both jurisdictions (Brexit complication). - **EUDAMED voluntary trap**: Some modules voluntary now -- but UDI/registration becomes mandatory once Commission declares EUDAMED fully functional (expected late 2026). - **Wellness device pivot**: Adding ANY diagnostic claim to wellness wearable = medical device. Marketing materials must align with cleared/CE-marked indications. - **ISO 13485 not enough alone**: ISO 13485 is QMS only. MDR requires QMS PLUS clinical evidence PLUS technical file PLUS PMS system. Cert alone = not CE marking. ## Cross-references - `claims-substantiation` -- general wellness vs medical claim boundary - `electronics-compliance` -- IEC 60601 overlap with LVD/EMC for electromedical devices - `labeling-compliance` -- MDR Annex I Chapter III labelling + UDI - `product-safety-incident` -- MDR vigilance vs general product safety overlap - `regulatory-calendar` -- MDR/IVDR transition deadlines, PSUR cycles, certificate renewals
在 GitHub 查看