Skip to main content

neqsim-flow-accelerated-corrosion

Flow-accelerated corrosion (FAC) and high-temperature pH in closed heating- and cooling-medium loops — magnetite film stability, mass-transfer-controlled wall thinning at bends and welds, wall shear stress, in-situ pH at operating temperature versus laboratory pH, alkaline margin above neutrality, and Cr-Mo material upgrade screening. USE WHEN: a task involves localised wall thinning or leaks at bends, elbows or circumferential welds in carbon-steel tubing; a closed glycol/water or water heating-medium, cooling-medium, boiler-feedwater or condensate loop; a WHRU, steam generator or economiser tube bundle; pH control of an amine-buffered loop; or any question of the form 'is the fluid alkaline enough at operating temperature?'. Anchors on neqsim.process.corrosion.

Aller à l'installation

Informations de source

Dépôt
equinor/neqsim
Dernière activité de la source
9 août 2026 à 05:44
Langue détectée de SKILL.md
anglais
Étoiles
147
Forks
64

Options d'installation

Le prompt qui vérifie d'abord la source est sélectionné par défaut. Vous pouvez passer à une commande directe ou télécharger une copie locale.

Vérifiez les fichiers source

Lisez SKILL.md et les fichiers associés affichés par SkillsMP avant de décider de l'installer.