一键导入
multifamily-residential-construction
Guide multifamily residential construction projects including apartments, affordable housing, and mixed-use developments.
用 Codex 或 Claude 帮你安装 复制这段 Prompt,粘贴到 Codex、Claude 或其他助手里,让它检查 Skill 页面并帮你完成安装。
菜单
Guide multifamily residential construction projects including apartments, affordable housing, and mixed-use developments.
用 Codex 或 Claude 帮你安装 复制这段 Prompt,粘贴到 Codex、Claude 或其他助手里,让它检查 Skill 页面并帮你完成安装。
基于 SOC 职业分类
Building envelope systems including curtain wall, roofing, waterproofing, cladding, and the four control layers for construction managers.
Guides PMs on contemporaneous recordkeeping, delay notices, and documentation practices that support potential construction claims.
Guides construction PMs through building commissioning, TAB, punch lists, O&M documentation, warranties, and project closeout.
Contract administration guidance for construction PMs—notice requirements, change orders, T&M documentation, claims, liens, and subcontract management.
Guidance for construction PMs on correctional facilities, jails, and detention centers including security systems, codes, and specialized building requirements.
Construction management for museums, cultural centers, galleries, archives, and institutional facilities requiring specialized environmental control and collection protection.
| name | multifamily-residential-construction |
| description | Guide multifamily residential construction projects including apartments, affordable housing, and mixed-use developments. |
Comprehensive reference for construction project managers working on multifamily residential projects including market-rate apartments, affordable/LIHTC housing, student housing, senior living, and mixed-use developments.
| Project Type | Key Considerations | Primary Reference |
|---|---|---|
| Market-Rate Apartments | Unit mix, finish tiers, lease-up timing | market-rate-development.md |
| LIHTC Affordable | QAP compliance, income targeting, cost certification | affordable-lihtc.md |
| HUD-Financed | Davis-Bacon, HUD inspections, 221(d)(4) requirements | hud-financing-compliance.md |
| State HFA Programs | State-specific requirements, bond financing | state-housing-agencies.md |
| Mixed-Use | Occupancy separation, shared parking, separate systems | mixed-use-multifamily.md |
| Student Housing | Bed count, academic calendar, durability | student-housing.md |
| Senior Independent Living | Age restrictions, accessibility, amenity programming | senior-independent-living.md |
| Micro-Units/Co-Living | Minimum size, shared amenities, dense layouts | micro-units-coliving.md |
| Method | Best For | Key Issues | Reference |
|---|---|---|---|
| Podium (Wood over Concrete) | 4-7 story, urban infill | Type transitions, fire separation | podium-construction.md |
| Modular/Prefab | Repetitive units, tight schedules | Factory QC, transport, connections | modular-prefab.md |
| Adaptive Reuse | Office/hotel conversion | Structural constraints, code change | adaptive-reuse-conversion.md |
| Topic | Key Codes | Reference |
|---|---|---|
| Fair Housing Design | FHA, ADA, IBC Chapter 11 | fair-housing-design.md |
| R-2 Occupancy | IBC Chapter 4, 5, 9 | r2-occupancy-code.md |
| High-Rise Requirements | IBC 403, NFPA 14 | highrise-multifamily.md |
| Fire/Life Safety | NFPA 13/13R, NFPA 72 | fire-life-safety.md |
| Egress/Corridors | IBC Chapter 10 | egress-corridors.md |
| Balconies/Guardrails | IBC 1015, IRC R312 | balconies-guardrails.md |
| Topic | Key Considerations | Reference |
|---|---|---|
| Unit Mix Planning | Ratio strategy, stacking, efficiency | unit-mix-planning.md |
| Finish Packages | Base vs. upgrade tiers, selections | finish-packages-upgrades.md |
| Kitchen/Bath | Cabinets, counters, fixtures by tier | kitchen-bath-specifications.md |
| Unit Accessibility | Type A vs. B, FHA requirements | unit-accessibility.md |
| Amenity Type | Key Considerations | Reference |
|---|---|---|
| Fitness/Wellness | Equipment, layout, accessibility | amenity-spaces.md |
| Parking Structures | Ratios, ADA, EV, ventilation | parking-structures.md |
| Rooftop Amenities | Structural, waterproofing, wind | rooftop-amenities.md |
| Package Rooms | Sizing, lockers, carrier integration | package-delivery-rooms.md |
| Bike/Micromobility | Storage requirements, e-bike charging | bike-micromobility.md |
| System | Options | Reference |
|---|---|---|
| Unit HVAC | PTAC, mini-split, VRF, central | unit-hvac-systems.md |
| Domestic Hot Water | Central vs. individual, heat pump | domestic-hot-water.md |
| Electrical Metering | Master, individual, sub-metered | electrical-metering.md |
| EV Charging | Ready, capable, installed levels | ev-charging-infrastructure.md |
| Telecom/Data | FTTH, WiFi, smart building | telecom-infrastructure.md |
| Phase | Key Activities | Reference |
|---|---|---|
| Unit Turnover | Inspections, punch, trade-backs | unit-turnover-punchlist.md |
| Phased TCO | Fire separation, life safety phasing | phased-occupancy-tco.md |
| Model/Leasing | Model timing, leasing office, tours | model-unit-leasing.md |
| PM Coordination | Handoff, training, warranty | property-management-coordination.md |
| Role Category | Key Players | Reference |
|---|---|---|
| Development Team | Developer, investor, lender, syndicator | multifamily-stakeholders.md |
| Design Team | Architect, interior designer, landscape | multifamily-stakeholders.md |
| Operations Team | Property management, leasing, marketing | multifamily-stakeholders.md |
| Division | Key Sections for Multifamily | Reference |
|---|---|---|
| Div 06-09 | Framing, envelope, finishes | specifications-csi.md |
| Div 10-14 | Specialties, appliances, elevators | specifications-csi.md |
| Div 21-28 | Fire protection, MEP, low-voltage | specifications-csi.md |
| Div 32 | Site, landscape, parking | specifications-csi.md |
| Milestone | Typical Timing | Key Deliverables |
|---|---|---|
| Unit Type Approval | SD/DD | Floor plans, unit mix confirmed |
| Finish Selections | 60% CD | Base and upgrade specifications |
| Model Unit Complete | 4-6 months before TCO | Staged model, photography |
| First TCO | Per phasing plan | Life safety complete, units ready |
| Substantial Completion | Per contract | All units, amenities complete |
| Final CO | 30-90 days after SC | All punch complete, close-out docs |
| Stabilization | 12-18 months post-CO | 90%+ occupancy achieved |
| Issue | Prevention Strategy | Reference |
|---|---|---|
| Unit count changes late | Lock unit mix at DD | unit-mix-planning.md |
| Finish selection delays | Establish hard cut-off dates | finish-packages-upgrades.md |
| Accessibility violations | Third-party FHA review | fair-housing-design.md |
| TCO delays | Early life safety coordination | phased-occupancy-tco.md |
| Punch list backlog | Inspection cadence, trade-back schedule | unit-turnover-punchlist.md |
| LIHTC compliance issues | QAP checklist from project start | affordable-lihtc.md |