neqsim-depressurization-mdmt

Étoiles132
Forks54
Mis à jour30 juin 2026 à 16:17

Emergency depressurization (blowdown) per API 521 §5.20 and minimum design metal temperature (MDMT) assessment per ASME UCS-66 / API 579 / EN 13445 — VU-flash transient inventory model, time-to-target-pressure, low-temperature embrittlement screening, and integration with PSV/flare loads. USE WHEN: a task requires sizing a blowdown valve, generating a P-vs-time curve for a vessel under fire / depressurization, checking MDMT against blowdown end-temperature, providing source terms for relief and flare networks, or distinguishing blowdown from trapped-liquid fire rupture screening. Anchors on neqsim.process.safety.depressurization.DepressurizationSimulator and neqsim.process.safety.mdmt.MDMTCalculator.

Installation

Installer avec Codex ou Claude Copiez ce prompt, collez-le dans Codex, Claude ou un autre assistant, puis laissez-le vérifier la page du skill et l'installer pour vous.

SKILL.md
readonly