Skip to main content

ground-up-office-mixed-use-construction

Construction management guidance for ground-up office buildings and mixed-use developments including core/shell, tenant coordination, and high-rise requirements.

설치로 이동

소스 정보

저장소
Construction-Gamma/construction-gamma-skills
최근 소스 활동
2026년 2월 28일 12:02
감지된 SKILL.md 언어
영어
스타
11
포크
5

설치 방법

기본적으로 소스를 먼저 확인하는 Prompt가 선택됩니다. 직접 명령으로 전환하거나 로컬 사본을 다운로드할 수도 있습니다.

소스 파일 검토

설치 여부를 결정하기 전에 SKILL.md와 SkillsMP에 표시된 보조 파일을 읽어 보세요.

파일 탐색기
57 개 파일

SKILL.md 표시 중

SKILL.md
소스 지침 · 읽기 전용 미리보기
name
ground-up-office-mixed-use-construction
description
Construction management guidance for ground-up office buildings and mixed-use developments including core/shell, tenant coordination, and high-rise requirements.
# Ground-Up Office & Mixed-Use Construction This skill provides comprehensive guidance for construction project managers working on ground-up office buildings and mixed-use developments. Coverage includes speculative office, build-to-suit, corporate headquarters, and complex mixed-use projects with retail, residential, and parking components. ## Quick Reference: Project Type Selection | Project Type | Key Characteristics | Primary Reference | |--------------|---------------------|-------------------| | Speculative Office | Unknown tenants, flexible design, market-driven | [speculative-office.md](references/speculative-office.md) | | Build-to-Suit | Single tenant, custom design, lease-driven | [build-to-suit-office.md](references/build-to-suit-office.md) | | Corporate HQ | Owner-occupied, brand-driven, amenity-rich | [corporate-headquarters.md](references/corporate-headquarters.md) | | Mixed-Use | Multiple uses, complex coordination | [mixed-use-developments.md](references/mixed-use-developments.md) | ## Quick Reference: Building Height Classification | Classification | Height Definition | Key Code Triggers | Primary Reference | |----------------|-------------------|-------------------|-------------------| | Low-Rise | 1-4 stories, <60' | Type V construction possible | [mid-rise-low-rise-office.md](references/mid-rise-low-rise-office.md) | | Mid-Rise | 5-12 stories, 60-150' | Type I/II required | [mid-rise-low-rise-office.md](references/mid-rise-low-rise-office.md) | | High-Rise | 75'+ occupied floor | Full high-rise package | [high-rise-office.md](references/high-rise-office.md) | ## Quick Reference: Delivery Model | Delivery Type | Definition | Typical Use | Primary Reference | |---------------|------------|-------------|-------------------| | Core & Shell | Base building only, tenant builds out | Speculative office | [core-shell-vs-turnkey.md](references/core-shell-vs-turnkey.md) | | Warm Shell | Core & shell + basic HVAC, ceiling grid | Retail, some office | [core-shell-vs-turnkey.md](references/core-shell-vs-turnkey.md) | | Turnkey | Fully finished, move-in ready | Build-to-suit, spec suites | [core-shell-vs-turnkey.md](references/core-shell-vs-turnkey.md) | ## Quick Reference: Core Configurations | Configuration | Best For | Efficiency Range | Primary Reference | |---------------|----------|------------------|-------------------| | Central Core | High-rise, single tenant | 80-85% | [core-configurations.md](references/core-configurations.md) | | Side Core | Views on three sides, daylight | 82-87% | [core-configurations.md](references/core-configurations.md) | | Split Core | Large floor plates, flexibility | 78-83% | [core-configurations.md](references/core-configurations.md) | ## Quick Reference: Structural Systems | System | Typical Application | Span Capability | Primary Reference | |--------|---------------------|-----------------|-------------------| | Steel Frame | High-rise, long spans | 40-60'+ | [structural-systems-office.md](references/structural-systems-office.md) | | Concrete Frame | Mid-rise, cost efficiency | 30-40' | [structural-systems-office.md](references/structural-systems-office.md) | | Composite | High-rise, speed | 35-50' | [structural-systems-office.md](references/structural-systems-office.md) | | Post-Tensioned | Thin slabs, parking | 55-65' | [structural-systems-office.md](references/structural-systems-office.md) | ## Quick Reference: Facade Systems | System | Application | Cost Range | Primary Reference | |--------|-------------|------------|-------------------| | Unitized Curtain Wall | High-rise, fast enclosure | $$$ | [curtain-wall-systems.md](references/curtain-wall-systems.md) | | Stick-Built Curtain Wall | Mid-rise, custom | $$ | [curtain-wall-systems.md](references/curtain-wall-systems.md) | | Punched Windows | Low/mid-rise, traditional | $ | [punched-window-systems.md](references/punched-window-systems.md) | ## Quick Reference: Parking Types | Type | When to Use | Cost/Space | Primary Reference | |------|-------------|------------|-------------------| | Below-Grade | Dense urban, high land cost | $$$$ | [below-grade-parking.md](references/below-grade-parking.md) | | Above-Grade Structure | Urban/suburban, moderate density | $$ | [structured-parking.md](references/structured-parking.md) | | Surface | Suburban, low land cost | $ | [surface-parking-site.md](references/surface-parking-site.md) | ## Quick Reference: Mixed-Use Separations | Adjacent Uses | Required Separation | Key Considerations | Primary Reference | |---------------|---------------------|-------------------|-------------------| | Office/Retail | 1-hour (sprinklered) | Separate entries, MEP | [occupancy-separation-requirements.md](references/occupancy-separation-requirements.md) | | Office/Residential | 2-hour | Acoustic, separate cores | [occupancy-separation-requirements.md](references/occupancy-separation-requirements.md) | | Office/Parking | 2-hour | Ventilation, egress | [occupancy-separation-requirements.md](references/occupancy-separation-requirements.md) | ## Quick Reference: High-Rise Code Triggers | Requirement | Trigger Height | Code Reference | Primary Reference | |-------------|----------------|----------------|-------------------| | High-Rise Package | 75' occupied floor | IBC 403 | [high-rise-code-requirements.md](references/high-rise-code-requirements.md) | | Sprinkler Required | 75' (sooner in many uses) | IBC 903.2 | [high-rise-code-requirements.md](references/high-rise-code-requirements.md) | | Fire Command Center | 75' | IBC 403.4.5 | [fire-command-emergency.md](references/fire-command-emergency.md) | | Standpipe Required | 30'+ | IBC 905.3 | [high-rise-code-requirements.md](references/high-rise-code-requirements.md) | ## Reference File Index ### Project Types & Delivery - [project-types-overview.md](references/project-types-overview.md) - Comprehensive project type guide - [speculative-office.md](references/speculative-office.md) - Spec development requirements - [build-to-suit-office.md](references/build-to-suit-office.md) - Single-tenant development - [corporate-headquarters.md](references/corporate-headquarters.md) - Owner-occupied facilities - [mixed-use-developments.md](references/mixed-use-developments.md) - Multi-use project coordination - [high-rise-office.md](references/high-rise-office.md) - High-rise construction - [mid-rise-low-rise-office.md](references/mid-rise-low-rise-office.md) - Smaller scale office - [core-shell-vs-turnkey.md](references/core-shell-vs-turnkey.md) - Delivery models ### Building Design & Structure - [core-configurations.md](references/core-configurations.md) - Core layout strategies - [structural-systems-office.md](references/structural-systems-office.md) - Structural options - [floor-plate-efficiency.md](references/floor-plate-efficiency.md) - Area optimization - [floor-to-floor-heights.md](references/floor-to-floor-heights.md) - Vertical dimensions - [column-grid-bay-spacing.md](references/column-grid-bay-spacing.md) - Structural grid planning ### Building Envelope - [curtain-wall-systems.md](references/curtain-wall-systems.md) - Curtain wall design - [punched-window-systems.md](references/punched-window-systems.md) - Traditional fenestration - [podium-tower-transitions.md](references/podium-tower-transitions.md) - Mixed-form buildings - [roofing-green-roof.md](references/roofing-green-roof.md) - Roof systems - [plaza-hardscape-integration.md](references/plaza-hardscape-integration.md) - Ground plane ### Vertical Transportation - [elevator-systems-traffic.md](references/elevator-systems-traffic.md) - Elevator design - [elevator-lobby-design.md](references/elevator-lobby-design.md) - Lobby planning - [freight-service-elevators.md](references/freight-service-elevators.md) - Service elevators - [escalators-mixed-use.md](references/escalators-mixed-use.md) - Escalator applications ### MEP Systems - [office-hvac-systems.md](references/office-hvac-systems.md) - HVAC design - [electrical-distribution-metering.md](references/electrical-distribution-metering.md) - Power systems - [plumbing-risers-tenant.md](references/plumbing-risers-tenant.md) - Plumbing design - [life-safety-systems-office.md](references/life-safety-systems-office.md) - Fire/life safety ### Parking & Site - [structured-parking.md](references/structured-parking.md) - Parking structures - [below-grade-parking.md](references/below-grade-parking.md) - Underground parking - [surface-parking-site.md](references/surface-parking-site.md) - Surface lots - [loading-service-areas.md](references/loading-service-areas.md) - Service facilities ### Mixed-Use Integration - [retail-podium-integration.md](references/retail-podium-integration.md) - Retail components - [residential-mixed-use.md](references/residential-mixed-use.md) - Residential integration - [occupancy-separation-requirements.md](references/occupancy-separation-requirements.md) - Code separations - [separate-entries-cores.md](references/separate-entries-cores.md) - Multi-use circulation - [condominium-air-rights.md](references/condominium-air-rights.md) - Legal structures ### Tenant Coordination - [base-building-standards.md](references/base-building-standards.md) - Work letter standards - [tenant-design-criteria.md](references/tenant-design-criteria.md) - Design guidelines - [tenant-improvement-allowance.md](references/tenant-improvement-allowance.md) - TI structures - [landlord-tenant-scope.md](references/landlord-tenant-scope.md) - Scope delineation ### Amenities & Common Areas - [lobby-reception-design.md](references/lobby-reception-design.md) - Main lobby design
GitHub에서 보기
이 SKILL.md는 매우 커서 SkillsMP가 여기에는 첫 섹션만 미리 보여줍니다. GitHub에서 보기