- name
- hospitality-construction
- description
- Hotel and hospitality construction guidance for guest rooms, F&B, meeting spaces, amenities, brand standards, and phased renovation operations.
# Hospitality Construction Quick Reference
## Hotel Property Types
| Property Type | Typical Keys | F&B Scope | Meeting Space | Construction $/Key |
|--------------|--------------|-----------|---------------|-------------------|
| Select-Service | 80-150 | Breakfast only | Limited/None | $80K-$120K |
| Full-Service | 150-500+ | Multiple outlets | Extensive | $150K-$250K |
| Luxury | 100-400 | Signature + casual | Full service | $400K-$800K+ |
| Boutique | 50-150 | Destination F&B | Limited | $200K-$400K |
| Extended-Stay | 100-200 | Kitchen/pantry | None | $70K-$110K |
| Resort | 200-1000+ | Multiple concepts | Full + outdoor | $300K-$600K |
| Conference Center | 150-400 | Group dining | Primary focus | $200K-$350K |
| Casino Hotel | 500-3000+ | Extensive | Large ballroom | $400K-$1M+ |
**Detailed guidance:** [references/select-service-hotels.md](references/select-service-hotels.md) | [references/full-service-hotels.md](references/full-service-hotels.md) | [references/luxury-hotels.md](references/luxury-hotels.md) | [references/boutique-hotels.md](references/boutique-hotels.md) | [references/extended-stay.md](references/extended-stay.md) | [references/resorts.md](references/resorts.md) | [references/conference-centers.md](references/conference-centers.md) | [references/casino-hotels.md](references/casino-hotels.md)
---
## Brand Standards & Franchise
| Topic | Key Consideration | Reference |
|-------|------------------|-----------|
| Brand Standards | Design review stages, prototype compliance | [references/brand-standards-franchise.md](references/brand-standards-franchise.md) |
| PIP Renovations | Property Improvement Plan scope and negotiation | [references/pip-renovations.md](references/pip-renovations.md) |
| Independent vs. Branded | Franchise fees, flexibility, distribution | [references/independent-vs-branded.md](references/independent-vs-branded.md) |
---
## Guest Room Design
| Component | Key Standards | Reference |
|-----------|--------------|-----------|
| Room Types | King, DD, suites, ADA configurations | [references/guest-room-types.md](references/guest-room-types.md) |
| Room Configurations | Layout by tier, dimensions, amenities | [references/guest-room-configurations.md](references/guest-room-configurations.md) |
| Bathroom Design | Vanity, shower/tub, finishes by tier | [references/guest-bathroom-design.md](references/guest-bathroom-design.md) |
| Casework & FF&E | Furniture, fixtures, procurement | [references/casework-ffe-coordination.md](references/casework-ffe-coordination.md) |
| In-Room Technology | HVAC controls, TV, WiFi, mobile key | [references/in-room-technology.md](references/in-room-technology.md) |
### Guest Room Size Standards by Tier
| Tier | Standard King | Standard DD | Junior Suite | One-BR Suite |
|------|--------------|-------------|--------------|--------------|
| Economy | 250-280 SF | 260-300 SF | N/A | N/A |
| Midscale | 280-320 SF | 300-340 SF | 350-400 SF | N/A |
| Upper Midscale | 300-350 SF | 320-380 SF | 400-450 SF | 500-600 SF |
| Upscale | 350-400 SF | 380-420 SF | 450-550 SF | 600-750 SF |
| Upper Upscale | 380-450 SF | 400-480 SF | 500-650 SF | 700-900 SF |
| Luxury | 450-600+ SF | 500-650+ SF | 650-900 SF | 900-1400+ SF |
---
## Public Areas & Arrival
| Space | Key Considerations | Reference |
|-------|-------------------|-----------|
| Lobby & Arrival | First impression, zones, accessibility | [references/lobby-arrival.md](references/lobby-arrival.md) |
| Front Desk & Back Office | Configurations, PMS, cash handling | [references/front-desk-back-office.md](references/front-desk-back-office.md) |
| Corridors & Elevator Lobbies | Width, finishes, sound, code | [references/corridors-elevator-lobbies.md](references/corridors-elevator-lobbies.md) |
| Wayfinding & Signage | Brand standards, ADA, digital | [references/wayfinding-signage.md](references/wayfinding-signage.md) |
---
## Food & Beverage
| Facility | Key Requirements | Reference |
|----------|-----------------|-----------|
| Restaurant Design | Layout, seating, kitchen adjacency | [references/restaurant-design.md](references/restaurant-design.md) |
| Bar & Lounge | Front/back bar, equipment, seating | [references/bar-lounge-design.md](references/bar-lounge-design.md) |
| Commercial Kitchen | Hood systems, equipment, health code | [references/commercial-kitchen.md](references/commercial-kitchen.md) |
| Banquet Kitchen | Hot/cold holding, plating, storage | [references/banquet-catering-kitchen.md](references/banquet-catering-kitchen.md) |
| Room Service | Delivery, staging, equipment | [references/room-service-operations.md](references/room-service-operations.md) |
| Breakfast & Buffet | Buffet layout, grab-and-go, equipment | [references/breakfast-buffet.md](references/breakfast-buffet.md) |
### Kitchen Sizing Guidelines
| Property Type | Covers/Meal Period | Kitchen SF | Kitchen:Dining Ratio |
|--------------|-------------------|------------|---------------------|
| Select-Service | 50-100 | 800-1,200 | 0.3:1 |
| Full-Service | 150-300 | 2,500-4,500 | 0.4:1 |
| Luxury | 200-400 | 4,000-8,000 | 0.5:1 |
| Resort (multiple outlets) | 500-1,500 | 8,000-20,000 | 0.4:1 |
---
## Meeting & Event Spaces
| Space | Key Standards | Reference |
|-------|--------------|-----------|
| Ballroom & Meeting Rooms | Sizing, ceiling height, divisibility | [references/ballroom-meeting-rooms.md](references/ballroom-meeting-rooms.md) |
| Pre-Function & Foyer | Registration, catering, flow | [references/prefunction-foyer.md](references/prefunction-foyer.md) |
| AV & Technology | Projection, audio, hybrid meetings | [references/meeting-av-technology.md](references/meeting-av-technology.md) |
| Breakout & Boardrooms | Sizing, configurations, technology | [references/breakout-boardrooms.md](references/breakout-boardrooms.md) |
### Meeting Room Capacity Matrix (SF per person)
| Setup | SF/Person | 1,000 SF Room | 2,500 SF Room | 5,000 SF Room |
|-------|-----------|---------------|---------------|---------------|
| Theater | 8-10 | 100-125 | 250-310 | 500-625 |
| Classroom | 15-18 | 55-65 | 140-165 | 280-330 |
| Banquet (rounds) | 12-14 | 70-85 | 180-210 | 360-420 |
| U-Shape | 25-30 | 35-40 | 85-100 | 165-200 |
| Conference | 20-25 | 40-50 | 100-125 | 200-250 |
| Reception | 6-8 | 125-165 | 310-415 | 625-830 |
---
## Amenities & Recreation
| Facility | Key Requirements | Reference |
|----------|-----------------|-----------|
| Pool & Spa | Indoor/outdoor, health code, ADA | [references/pool-spa-facilities.md](references/pool-spa-facilities.md) |
| Fitness Center | Equipment, sizing, access | [references/fitness-center.md](references/fitness-center.md) |
| Resort Recreation | Golf, tennis, water sports | [references/resort-recreation.md](references/resort-recreation.md) |
| Retail & Gift Shop | Sizing, merchandise, POS | [references/retail-gift-shops.md](references/retail-gift-shops.md) |
---
## Back-of-House Operations
| Function | Key Considerations | Reference |
|----------|-------------------|-----------|
| Housekeeping & Linen | Par stock, distribution, storage | [references/housekeeping-linen.md](references/housekeeping-linen.md) |
| Laundry Facilities | OPL sizing, equipment, workflow | [references/laundry-facilities.md](references/laundry-facilities.md) |
| Employee Facilities | Lockers, cafeteria, training | [references/employee-facilities.md](references/employee-facilities.md) |
| Receiving & Storage | Loading dock, inventory, security | [references/receiving-storage-loading.md](references/receiving-storage-loading.md) |
| MEP & Engineering | Mechanical rooms, maintenance | [references/mep-engineering-spaces.md](references/mep-engineering-spaces.md) |
### Back-of-House Sizing Ratios
| Hotel Type | BOH % of Gross | Employee Ratio | Linen Par Stock |
|------------|---------------|----------------|-----------------|
| Select-Service | 15-20% | 0.3-0.4 FTE/room | 2.5 par |
| Full-Service | 25-30% | 0.6-0.8 FTE/room | 3.0 par |
| Luxury | 30-40% | 1.0-1.5 FTE/room | 4.0 par |
| Resort | 35-45% | 1.2-2.0 FTE/room | 4.0 par |
---
## Building Systems
| System | Hotel-Specific Considerations | Reference |
|--------|------------------------------|-----------|
| Guest Room HVAC | PTAC, fan coil, VRF options | [references/guest-room-hvac.md](references/guest-room-hvac.md) |
| Keycard & Access Control | RFID, mobile key, PMS integration | [references/keycard-access-control.md](references/keycard-access-control.md) |
| PMS Integration | Property management, interfaces | [references/pms-integration.md](references/pms-integration.md) |
GitHub에서 보기